Estudio incluido
Towards energy efficient scheduling in the olive oil extraction industry: Comparative assessment of energy consumption in two management models
1Ficha bibliográfica
- Autores
- Claudio Perone, Roberto Romaniello, Alessandro Leone, Antonio Berardi, Antonia Tamborrino
- Año
- 2022
- Publicación
- Energy Conversion and Management X
- País
- —
- Segmento
- Procesamiento de frutas y vegetales
- Familia de procesos
- Faena, corte y procesamiento primario
- Tipo de estudio
- Estudio de casos múltiples
- Alcance de la extracción
- Texto completo
- Tamaño
- 1 plantas · 2 líneas · — máquinas
- Periodo de observación
- 30 días
- Recolección de datos
- automatic_monitoring
- Intervención
Ver el contexto tal como lo describe el estudio
The experimental tests were carried out in an industrial olive oil mill equipped with two production lines: a batch processing line (Ba-PL) of medium hourly capacity, mainly used to process the olives of small producers; a continuous processing line (Co-PL) having large hourly capacity, used to process olives from farms with large groves.
2Riesgo de sesgo
Puntuado con la rúbrica del protocolo: 2 preocupación baja, 1 algunas preocupaciones, 0 preocupación alta.
Puntuación total 15Riesgo bajo
| Ítem | Puntuación |
|---|---|
| Is the observed line, machine or plant described well enough to classify its segment, process and equipment?Product, process and equipment are all described. | 2 / 2 |
| Is the observation period long enough and reported?Period reported and at least 30 days of production (or at least 100 recorded events). | 2 / 2 |
| How were loss data collected?Automatic line monitoring, or systematic logs covering every stop in the period. | 2 / 2 |
| Are OEE, loading time and the loss categories defined explicitly?Formulae or definitions are given for the reported metrics, including what counts as planned time. | 2 / 2 |
| Does the loss breakdown account for the total loss it claims to explain?Only the top causes are reported and the unexplained remainder can be computed. | 1 / 2 |
| Is there evidence of selective reporting of favourable results?Observational study, or intervention study that reports baseline and post-intervention data with the same method. | 2 / 2 |
| Are the reported numbers internally consistent?Recomputed totals, shares and OEE factors agree with the reported values within 2 percentage points. | 2 / 2 |
| Could conflicts of interest or the source of the data bias the result?Academic or independent study, or conflicts declared and unrelated to the result. | 2 / 2 |
3Datos extraídos
Cada dato con su clasificación y la cita textual que lo establece.
| Causa reportada | Categoría de pérdida | Métrica | Valor | Extracción |
|---|---|---|---|---|
—Ver cita textual (Table 3, Peranzana average row)92.4 ± 1.7 a 54.7 ± 2.1 a 100.0 a 50.5 ± 1.3 a 94.3 ± 2.5 a 99.5 ± 0.5 a 100.0 ± 0.0 a 93.9 ± 2.4 a | none | Calidad | 100 % | Ambos extractores coincidieron |
—Ver cita textual (Table 3, Arbequina average row)94.7 ± 2.1 a 54.4 ± 1.0 a 100.0 ± 0.0 a 51.5 ± 1.5 a 94.3 ± 2.8 a 98.7 ± 0.9 a 100.0 ± 0.0 a 93.1 ± 2.1 a | none | OEE | 93.1 % | Ambos extractores coincidieron |
—Ver cita textual (Table 3, Arbequina average row)94.7 ± 2.1 a 54.4 ± 1.0 a 100.0 ± 0.0 a 51.5 ± 1.5 a 94.3 ± 2.8 a 98.7 ± 0.9 a 100.0 ± 0.0 a 93.1 ± 2.1 a | none | Rendimiento | 98.7 % | Ambos extractores coincidieron |
—Ver cita textual (Table 3, Arbequina average row)94.7 ± 2.1 a 54.4 ± 1.0 a 100.0 ± 0.0 a 51.5 ± 1.5 a 94.3 ± 2.8 a 98.7 ± 0.9 a 100.0 ± 0.0 a 93.1 ± 2.1 a | none | Disponibilidad | 94.3 % | Ambos extractores coincidieron |
—Ver cita textual (Table 3, Arbequina average row)94.7 ± 2.1 a 54.4 ± 1.0 a 100.0 ± 0.0 a 51.5 ± 1.5 a 94.3 ± 2.8 a 98.7 ± 0.9 a 100.0 ± 0.0 a 93.1 ± 2.1 a | none | OEE | 51.5 % | Ambos extractores coincidieron |
—Ver cita textual (Table 3, Arbequina average row)94.7 ± 2.1 a 54.4 ± 1.0 a 100.0 ± 0.0 a 51.5 ± 1.5 a 94.3 ± 2.8 a 98.7 ± 0.9 a 100.0 ± 0.0 a 93.1 ± 2.1 a | none | Rendimiento | 54.4 % | Ambos extractores coincidieron |
—Ver cita textual (Table 3, Arbequina average row)94.7 ± 2.1 a 54.4 ± 1.0 a 100.0 ± 0.0 a 51.5 ± 1.5 a 94.3 ± 2.8 a 98.7 ± 0.9 a 100.0 ± 0.0 a 93.1 ± 2.1 a | none | Disponibilidad | 94.7 % | Ambos extractores coincidieron |
—Ver cita textual (Results / Table 6)the specific energy for the Co-PL line was about half that of the other line (0.55 MJ kg−1 vs 1.05 MJ/kg) | none | Energía específica | 1.05 MJ (Kgoil)-1 | Ambos extractores coincidieron |
—Ver cita textual (Table 3, Arbequina average row)94.7 ± 2.1 a 54.4 ± 1.0 a 100.0 ± 0.0 a 51.5 ± 1.5 a 94.3 ± 2.8 a 98.7 ± 0.9 a 100.0 ± 0.0 a 93.1 ± 2.1 a | none | Calidad | 100 % | Un solo extractor |
—Ver cita textual (Table 3, Arbosana average row)92.8 ± 1.6 a 55.0 ± 2.5 a 100.0 a 51.0 ± 2.9 a 93.1 ± 2.4 a 99.1 ± 1.4 a 100.0 ± 0.0 a 92.3 ± 2.9 a | none | Disponibilidad | 92.8 % | Un solo extractor |
—Ver cita textual (Table 3, Arbosana average row)92.8 ± 1.6 a 55.0 ± 2.5 a 100.0 a 51.0 ± 2.9 a 93.1 ± 2.4 a 99.1 ± 1.4 a 100.0 ± 0.0 a 92.3 ± 2.9 a | none | Rendimiento | 55.0 % | Un solo extractor |
—Ver cita textual (Table 3, Arbosana average row)92.8 ± 1.6 a 55.0 ± 2.5 a 100.0 a 51.0 ± 2.9 a 93.1 ± 2.4 a 99.1 ± 1.4 a 100.0 ± 0.0 a 92.3 ± 2.9 a | none | OEE | 51.0 % | Un solo extractor |
—Ver cita textual (Table 3, Coratina average row)94.1 ± 2.0 a 54.9 ± 1.7 a 100.0 a 51.6 ± 1.0 a 94.5 ± 1.2 a 98.7 ± 1.0 a 100.0 ± 0.0 a 93.3 ± 1.9 a | none | Disponibilidad | 94.1 % | Un solo extractor |
—Ver cita textual (Table 3, Coratina average row)94.1 ± 2.0 a 54.9 ± 1.7 a 100.0 a 51.6 ± 1.0 a 94.5 ± 1.2 a 98.7 ± 1.0 a 100.0 ± 0.0 a 93.3 ± 1.9 a | none | Rendimiento | 54.9 % | Un solo extractor |
—Ver cita textual (Table 3, Coratina average row)94.1 ± 2.0 a 54.9 ± 1.7 a 100.0 a 51.6 ± 1.0 a 94.5 ± 1.2 a 98.7 ± 1.0 a 100.0 ± 0.0 a 93.3 ± 1.9 a | none | OEE | 51.6 % | Un solo extractor |
—Ver cita textual (Table 3, Peranzana average row)92.4 ± 1.7 a 54.7 ± 2.1 a 100.0 a 50.5 ± 1.3 a 94.3 ± 2.5 a 99.5 ± 0.5 a 100.0 ± 0.0 a 93.9 ± 2.4 a | none | Disponibilidad | 92.4 % | Un solo extractor |
—Ver cita textual (Table 3, Peranzana average row)92.4 ± 1.7 a 54.7 ± 2.1 a 100.0 a 50.5 ± 1.3 a 94.3 ± 2.5 a 99.5 ± 0.5 a 100.0 ± 0.0 a 93.9 ± 2.4 a | none | Rendimiento | 54.7 % | Un solo extractor |
—Ver cita textual (Table 3, Peranzana average row)92.4 ± 1.7 a 54.7 ± 2.1 a 100.0 a 50.5 ± 1.3 a 94.3 ± 2.5 a 99.5 ± 0.5 a 100.0 ± 0.0 a 93.9 ± 2.4 a | none | OEE | 50.5 % | Un solo extractor |
—Ver cita textual (Abstract)the Overall Equipment Effectiveness (OEE) analysis of performance for the two processes shows values of 93.1 % for the Co-PL configuration but only 51.2 % for Ba-PL | none | OEE | 51.2 % | Un solo extractor |
—Ver cita textual (Table 2)Arbequina Ba-PL 84.32 ± 1.20 a | none | Rendimiento másico | 84.3 % | Un solo extractor |
—Ver cita textual (Table 2)Arbosana Ba-PL 83.41 ± 0.85 a | none | Rendimiento másico | 83.4 % | Un solo extractor |
—Ver cita textual (Table 2)Coratina Ba-PL 86.45 ± 1.60 a | none | Rendimiento másico | 86.5 % | Un solo extractor |
—Ver cita textual (Table 2)Peranzana Ba-PL 87.51 ± 1.10 a | none | Rendimiento másico | 87.5 % | Un solo extractor |
—Ver cita textual (Table 6 / Results)The extraction yield of both plant configurations was estimated to be about 17 %, considering that the two lines both achieve equal overall efficiency. | none | Rendimiento másico | 17.0 % | Un solo extractor |
—Ver cita textual (Results / Table 5)the output of the Co-PL was estimated to be about 75 % higher, at respectively 12,240.00 kg vs 3060.00 kg of olive oil for the Ba-PL line | none | Capacidad de producción | 3,060 kg/day | Un solo extractor |
discontinuous plant feeding / bottleneck of hopper and conveyor beltcrusherVer cita textual (Results - Electrical and thermal energy consumed)The time lost (193 min) was due to discontinuous plant feeding as batches of olive crop arrived in the mill, and then following the washing step, the bottleneck of a sole hopper and conveyor belt leading to the crushing machines. | Microparos y esperas | Tiempo perdido | 193 min | Un solo extractor |
waiting time between batches (decanter draining before next batch)centrifuge (decanter)Ver cita textual (Results - Electrical and thermal energy consumed)Given the mass flow rate of 3000 kg h−1 for the centrifuge series, the time necessary for processing a 700 kg batch averaged 14 min, followed by the average 13 min of wait time between batches. | Microparos y esperas | Tiempo entre eventos | 13.0 min | Un solo extractor |
—Ver cita textual (Table 3, Arbosana average row)92.8 ± 1.6 a 55.0 ± 2.5 a 100.0 a 51.0 ± 2.9 a 93.1 ± 2.4 a 99.1 ± 1.4 a 100.0 ± 0.0 a 92.3 ± 2.9 a | none | Disponibilidad | 93.1 % | Un solo extractor |
—Ver cita textual (Table 3, Arbosana average row)92.8 ± 1.6 a 55.0 ± 2.5 a 100.0 a 51.0 ± 2.9 a 93.1 ± 2.4 a 99.1 ± 1.4 a 100.0 ± 0.0 a 92.3 ± 2.9 a | none | Rendimiento | 99.1 % | Un solo extractor |
—Ver cita textual (Table 3, Arbosana average row)92.8 ± 1.6 a 55.0 ± 2.5 a 100.0 a 51.0 ± 2.9 a 93.1 ± 2.4 a 99.1 ± 1.4 a 100.0 ± 0.0 a 92.3 ± 2.9 a | none | OEE | 92.3 % | Un solo extractor |
—Ver cita textual (Table 3, Coratina average row)94.1 ± 2.0 a 54.9 ± 1.7 a 100.0 a 51.6 ± 1.0 a 94.5 ± 1.2 a 98.7 ± 1.0 a 100.0 ± 0.0 a 93.3 ± 1.9 a | none | Disponibilidad | 94.5 % | Un solo extractor |
—Ver cita textual (Table 3, Coratina average row)94.1 ± 2.0 a 54.9 ± 1.7 a 100.0 a 51.6 ± 1.0 a 94.5 ± 1.2 a 98.7 ± 1.0 a 100.0 ± 0.0 a 93.3 ± 1.9 a | none | OEE | 93.3 % | Un solo extractor |
—Ver cita textual (Table 3, Peranzana average row)92.4 ± 1.7 a 54.7 ± 2.1 a 100.0 a 50.5 ± 1.3 a 94.3 ± 2.5 a 99.5 ± 0.5 a 100.0 ± 0.0 a 93.9 ± 2.4 a | none | Rendimiento | 99.5 % | Un solo extractor |
—Ver cita textual (Table 3, Peranzana average row)92.4 ± 1.7 a 54.7 ± 2.1 a 100.0 a 50.5 ± 1.3 a 94.3 ± 2.5 a 99.5 ± 0.5 a 100.0 ± 0.0 a 93.9 ± 2.4 a | none | OEE | 93.9 % | Un solo extractor |
—Ver cita textual (Table 6 / Results)The extraction yield of both plant configurations was estimated to be about 17 %, considering that the two lines both achieve equal overall efficiency. | none | Rendimiento másico | 17.0 % | Un solo extractor |
—Ver cita textual (Results / Table 6)the specific energy for the Co-PL line was about half that of the other line (0.55 MJ kg−1 vs 1.05 MJ/kg) | none | Energía específica | 0.550 MJ (Kgoil)-1 | Un solo extractor |
—Ver cita textual (Results / Table 5)the output of the Co-PL was estimated to be about 75 % higher, at respectively 12,240.00 kg vs 3060.00 kg of olive oil for the Ba-PL line | none | Capacidad de producción | 12,240 kg/day | Un solo extractor |
Unidades de observación
- Co-PL · Línea completa o equipo sin especificar · Línea base
- Ba-PL · Línea completa o equipo sin especificar · Línea base