Product loss at start-up/shut-down due to line design
Die wissenschaftlichen Inhalte dieser Seite werden auf Englisch und Spanisch veröffentlicht; hier werden sie auf Englisch angezeigt.
Kurz gefasst
Sie tritt bei weniger als 1 von 100 untersuchten Linien auf.
Wenn sie auftritt, entfällt auf sie im Mittel etwa 47 % der Verlustzeit der Linie. Berichtet von 1 der 127 Studien, die sie beobachten konnten (spärliche Evidenz).
Was passiert
The physical layout of the line (pipe lengths, dead legs, tank-to-filler distances, absence of product recovery or pigging systems) forces operators to purge or flush the product/water interface at every start-up and shut-down, discarding syrup or product that cannot be routed back to the process. The same design limitations also generate off-specification product during these transitions because mixing, dosing or temperature conditions are not yet stable, which shows up as non-conformity losses.
Was man dagegen tut
Redesign the line to minimize dead volume and transfer distances, and install product recovery, pigging or push-back systems that return usable syrup/product to the process instead of draining it. Add inline interface detection (density, conductivity or optical sensors) with automated diverter valves so only the true interface segment is rejected, and standardize start-up/shut-down sequences to shorten the unstable transition window.
Praktische Hinweise auf Basis ingenieurtechnischen Wissens; keine statistische Schätzung.
1Wahrscheinlichkeit und Evidenz
- Auftretenswahrscheinlichkeit
- 0,5 % [0,1–1,3 %]
- Erwarteter Anteil an der Verlustzeit
- 0,2 % [0,0–0,7 %]
- Anteil an der Verlustzeit bei Auftreten
- 47 % [29–67 %]
- Studien / Einheiten
- 127 / 161
- Evidenzgrad
- D
Grad D: 0 oder 1 Studie; die Schätzung beruht auf partiellem Pooling und Priori-Verteilungen, und das breite Intervall ist das Ergebnis.
2Wahrscheinlichkeit nach Segment
- Milchprodukte0,5 % [0,1–1,9 %]13 Studien
- Erfrischungsgetränke, abgefülltes Wasser und Säfte0,7 % [0,1–2,2 %]26 Studien
- Bier, Wein und Spirituosen0,5 % [0,1–2,0 %]11 Studien
- Backwaren und Teigwaren0,5 % [0,0–1,8 %]24 Studien
- Fleisch, Geflügel und Fisch0,5 % [0,0–1,9 %]9 Studien
- Obst- und Gemüseverarbeitung0,5 % [0,1–2,0 %]7 Studien
- Getreide- und Ölsaatenmüllerei0,5 % [0,0–2,2 %]6 Studien
- Zucker und Süßwaren0,5 % [0,0–2,0 %]9 Studien
- Snacks, Kaffee, Tee und sonstige Lebensmittel0,5 % [0,0–2,0 %]5 Studien
- Futtermittel und Heimtiernahrung0,5 % [0,1–1,8 %]7 Studien
- Lebensmittelherstellung (nicht spezifiziert oder gemischt)0,5 % [0,1–2,0 %]10 Studien
3Mechanismus, SCADA-Signatur und Gegenmaßnahme
Mechanismus
Ingenieurpraktische HinweiseThe physical layout of the line (pipe lengths, dead legs, tank-to-filler distances, absence of product recovery or pigging systems) forces operators to purge or flush the product/water interface at every start-up and shut-down, discarding syrup or product that cannot be routed back to the process. The same design limitations also generate off-specification product during these transitions because mixing, dosing or temperature conditions are not yet stable, which shows up as non-conformity losses.
So zeigt sie sich in SCADA-Daten
Ingenieurpraktische HinweiseRepeated start-up and shut-down state entries on the line timeline, often coinciding with drain/flush valve open commands or diverter-valve activations; interface or density/conductivity sensor trends show extended purge windows at run boundaries. Production counters show a gap between raw material (syrup/mix) consumption and first/last good units, and quality or MES event logs register non-conformity flags clustered around run-start and run-end timestamps.
Gegenmaßnahme
Ingenieurpraktische HinweiseRedesign the line to minimize dead volume and transfer distances, and install product recovery, pigging or push-back systems that return usable syrup/product to the process instead of draining it. Add inline interface detection (density, conductivity or optical sensors) with automated diverter valves so only the true interface segment is rejected, and standardize start-up/shut-down sequences to shorten the unstable transition window.
4Quellen
- An Example Application On Comparison Of Six Sigma And Kaizen From Total Quality Managment Techniquies (2018)Quelle öffnenVerlustzeit: 24.000 litre · laut Bericht: “Uygunsuzluk kayıpları”
Wörtliches Zitat anzeigen
Bu kayıpların temelinde yatan iki nedenden uygunsuzluk kayıplarının 24.000 litre ile mevcut şurup kaybının %42.1’ini hat dizaynı ile ilgili kayıpların ise 33.000 litre ile şurup kayıplarında %58 ini oluşturduğu anlaşılmıştır.
- An Example Application On Comparison Of Six Sigma And Kaizen From Total Quality Managment Techniquies (2018)Quelle öffnenVerlustzeit: 33.000 litre · laut Bericht: “Hat dizaynı ile ilgili kayıplar”
Wörtliches Zitat anzeigen
...hat dizaynı ile ilgili kayıpların ise 33.000 litre ile şurup kayıplarında %58 ini oluşturduğu anlaşılmıştır.
- An Example Application On Comparison Of Six Sigma And Kaizen From Total Quality Managment Techniquies (2018)Quelle öffnenAnteil an der Verlustzeit: 58,0 % · laut Bericht: “Hat dizaynı ile ilgili kayıplar”
Wörtliches Zitat anzeigen
...hat dizaynı ile ilgili kayıpların ise 33.000 litre ile şurup kayıplarında %58 ini oluşturduğu anlaşılmıştır.
- An Example Application On Comparison Of Six Sigma And Kaizen From Total Quality Managment Techniquies (2018)Quelle öffnenVerlustzeit: 87,5 litre · laut Bericht: “Üretim başlangıç ve bitişlerindeki şurup kaybı (hat dizaynı)”
Wörtliches Zitat anzeigen
Hat dizaynındaki kayıplarla ilgili yapılan ölçümlemelerin sonucunda ürün 1 ve ürün 2 kayıpların her üretim başlangıç ve bitiminde ortama 55’er litre, ürün 3 ve ürün 4 içinse ortalama 120 litre olmak üzere ortalamada 87.5 litre şurup kaybı olduğu belirlenmiştir.