Eingeschlossene Studie
Micro downtime: Data collection, analysis and impact on OEE in bottling lines the San Benedetto case study
1Bibliografische Angaben
- Autoren
- Ilenia Zennaro, Daria Battini, Fabio Sgarbossa, Alessandro Persona, Rosario De Marchi
- Jahr
- 2018
- Publikationsorgan
- International Journal of Quality & Reliability Management
- Land
- —
- Segment
- Erfrischungsgetränke, abgefülltes Wasser und Säfte
- Prozessfamilie
- Abfüll- und Verpackungslinie
- Studientyp
- Einzelfallstudie
- Extraktionsumfang
- Nur Abstract
- Umfang
- 1 Werke · 1 Linien · 3 Maschinen
- Beobachtungszeitraum
- —
- Datenerhebung
- not_reported
- Intervention
Umfeld laut Studie anzeigen
The case study presents a new detailed micro downtime data collection and statistical analysis in the beverage sector with the application of a numerical indicator, the CPI, in order to drive future actions.
2Verzerrungsrisiko
Bewertet nach dem Schema des Protokolls: 2 geringe Bedenken, 1 einige Bedenken, 0 hohe Bedenken.
Gesamtpunktzahl 4Hohes Risiko
| Kriterium | Punkte |
|---|---|
| Is the observed line, machine or plant described well enough to classify its segment, process and equipment?Product or sector is given but the equipment or process is only partly described. | 1 / 2 |
| Is the observation period long enough and reported?Period not reported. | 0 / 2 |
| How were loss data collected?Interviews, estimates, or method not reported. | 0 / 2 |
| Are OEE, loading time and the loss categories defined explicitly?No definition; metrics are reported as bare numbers. | 0 / 2 |
| Does the loss breakdown account for the total loss it claims to explain?Only selected causes are reported and the total is unknown. | 0 / 2 |
| Is there evidence of selective reporting of favourable results?Intervention study in which baseline and post-intervention periods differ in length or method. | 1 / 2 |
| Are the reported numbers internally consistent?Inconsistencies above 10 percentage points, or OEE factors above 100%. | 0 / 2 |
| Could conflicts of interest or the source of the data bias the result?Academic or independent study, or conflicts declared and unrelated to the result. | 2 / 2 |
3Extrahierte Daten
Jeder Datenpunkt mit seiner Einordnung und dem wörtlichen Zitat, das ihn belegt.
| Berichtete Ursache | Verlustkategorie | Kennzahl | Wert | Extraktion |
|---|---|---|---|---|
micro downtimeWörtliches Zitat anzeigen (Abstract)Micro downtime (downtime lower than 15 minutes) covers 57 percent of inefficiency. | Leerlauf und Kurzstillstände | Anteil an der Verlustzeit | 57,0 % | Einfache Extraktion |
Beobachtungseinheiten
- Least efficient production line · Gesamte Linie oder nicht spezifizierte Anlage · Ausgangslage