foratvise
Get Started
Equipment failure (breakdowns)

Compressed air leak

Equipment failure (breakdowns)AvailabilityForming, moulding and depositing

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 57 % of the line's lost time. Reported by 1 of the 76 studies that could observe it (sparse evidence).

What happens

Wear, cracking or loosening of pneumatic fittings, hoses, seals or valves in the compressed air circuit allows air to escape, so the forming actuators or cylinders lose the pressure and flow needed to complete their stroke reliably. As leakage increases the system struggles to maintain setpoint pressure, degrading actuator force and timing until the equipment can no longer operate and a repair intervention is required.

What is done about it

Implement a routine ultrasonic or soap-test leak detection and tagging program on the compressed air network, with prioritized repair or replacement of degraded fittings, hoses and seals. Reinforce preventive maintenance on pneumatic connections at the forming station and consider pressure monitoring with automated low-pressure alerts to trigger corrective action before the loss propagates to a stop.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.7% [0.1–1.9%]
Expected share of lost time
0.4% [0.1–1.1%]
Share of lost time when present
57% [46–67%]
Studies / units
76 / 96
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.8% [0.1–3.2%]5 studies
  • Soft drinks, bottled water and juices
    1.1% [0.1–4.0%]11 studies
  • Brewing, wine and spirits
    0.9% [0.1–3.4%]0 studies
  • Bakery and pasta
    0.7% [0.1–2.5%]25 studies
  • Meat, poultry and seafood
    0.8% [0.1–3.1%]3 studies
  • Fruit and vegetable processing
    0.8% [0.1–3.1%]3 studies
  • Grain and oilseed milling
    0.9% [0.1–3.6%]0 studies
  • Sugar and confectionery
    0.8% [0.1–3.1%]8 studies
  • Snacks, coffee, tea and other foods
    0.8% [0.1–2.8%]7 studies
  • Animal feed and pet food
    0.8% [0.1–3.1%]6 studies
  • Food manufacturing (unspecified or mixed)
    0.8% [0.1–2.9%]8 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

Wear, cracking or loosening of pneumatic fittings, hoses, seals or valves in the compressed air circuit allows air to escape, so the forming actuators or cylinders lose the pressure and flow needed to complete their stroke reliably. As leakage increases the system struggles to maintain setpoint pressure, degrading actuator force and timing until the equipment can no longer operate and a repair intervention is required.

How it looks in SCADA data

Engineering guidance

SCADA shows a sustained drop in compressed air header or local line pressure below setpoint, with the compressor or air receiver running more frequently or continuously to compensate, and low-pressure alarms on the forming station. The affected forming machine state log shows unplanned stop or fault state correlated with the pressure excursion, often with repeated cycle-time or actuator-position deviations preceding the stop.

Countermeasure

Engineering guidance

Implement a routine ultrasonic or soap-test leak detection and tagging program on the compressed air network, with prioritized repair or replacement of degraded fittings, hoses and seals. Reinforce preventive maintenance on pneumatic connections at the forming station and consider pressure monitoring with automated low-pressure alerts to trigger corrective action before the loss propagates to a stop.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Share of loss events: 26.0 % · as reported: “Vazamento de ar comprimido”
    Show verbatim quote
    O vazamento de ar comprimido também não foi validado como causa- raiz pois representava apenas 26 % das falhas, porém a equipe tomou como ação preventiva substituir todas as mangueiras de ar comprimido