Treated water supply failure
In short
It appears in fewer than 1 of every 100 lines studied.
When it appears, it takes on average about 56 % of the line's lost time. Reported by 0 of the 80 studies that could observe it (sparse evidence).
What happens
The container washer depends on a continuous supply of treated water at the required pressure, flow and quality; failure of the treatment skid, supply pump, filters or piping (fouling, valve or pump malfunction, pressure drop) interrupts or degrades the water reaching the wash stations. Without adequate treated water the washing, rinsing and disinfection spray nozzles cannot perform their cleaning function, forcing the washer to stop until the supply is restored.
What is done about it
Implement redundant treated-water pumps and a buffer/break tank sized to ride through short interruptions, with continuous monitoring of pressure, flow and water quality feeding into preventive alarms. Schedule regular inspection and cleaning of filters, strainers and treatment equipment, and maintain a documented response procedure to restore supply quickly.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.5% [0.1–1.4%]
- Expected share of lost time
- 0.3% [0.0–0.8%]
- Share of lost time when present
- 56% [45–66%]
- Studies / units
- 80 / 102
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.5% [0.0–2.0%]10 studies
- Soft drinks, bottled water and juices0.5% [0.0–1.7%]27 studies
- Brewing, wine and spirits0.5% [0.0–2.1%]12 studies
- Bakery and pasta0.6% [0.0–2.5%]0 studies
- Meat, poultry and seafood0.5% [0.0–2.2%]4 studies
- Fruit and vegetable processing0.5% [0.0–2.2%]4 studies
- Grain and oilseed milling0.6% [0.1–2.1%]3 studies
- Sugar and confectionery0.6% [0.0–2.4%]3 studies
- Snacks, coffee, tea and other foods0.5% [0.0–2.1%]4 studies
- Animal feed and pet food0.5% [0.1–2.1%]4 studies
- Food manufacturing (unspecified or mixed)0.5% [0.1–2.0%]9 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceThe container washer depends on a continuous supply of treated water at the required pressure, flow and quality; failure of the treatment skid, supply pump, filters or piping (fouling, valve or pump malfunction, pressure drop) interrupts or degrades the water reaching the wash stations. Without adequate treated water the washing, rinsing and disinfection spray nozzles cannot perform their cleaning function, forcing the washer to stop until the supply is restored.
How it looks in SCADA data
Engineering guidanceSCADA/MES shows a low-pressure or low-flow alarm on the treated water header feeding the washer, often paired with a pump-fault or filter-differential-pressure alarm upstream. The washer enters a fault or idle state with wash/rinse cycles halted, and downstream filling or capping equipment may show starvation as container flow stops.
Countermeasure
Engineering guidanceImplement redundant treated-water pumps and a buffer/break tank sized to ride through short interruptions, with continuous monitoring of pressure, flow and water quality feeding into preventive alarms. Schedule regular inspection and cleaning of filters, strainers and treatment equipment, and maintain a documented response procedure to restore supply quickly.