Included study
Overall equipment effectiveness (OEE) analysis to improve the effectiveness of vannamei (Litopenaeus vannamei) shrimp freezing machine performance at PT. XY, Situbondo-East Java
1Bibliographic record
- Authors
- N. Fakhri, L Supenti, G Prabawo
- Year
- 2019
- Venue
- IOP Conference Series Earth and Environmental Science
- Country
- Indonesia
- Segment
- Meat, poultry and seafood
- Process family
- Refrigeration and freezing
- Study type
- Single case study
- Extraction scope
- Abstract only
- Size
- 1 plants · 1 lines · 1 machines
- Observation period
- —
- Data collection
- not_reported
- Intervention
Show the setting as described by the study
PT. XY is a company engaged in the production of frozen vannamei shrimp which cannot be separated from the problems related to the proficiency of machine or equipment.
2Risk of bias
Scored with the rubric of the protocol: 2 low concern, 1 some concerns, 0 high concern.
Total score 7High risk
| Item | Score |
|---|---|
| Is the observed line, machine or plant described well enough to classify its segment, process and equipment?Product or sector is given but the equipment or process is only partly described. | 1 / 2 |
| Is the observation period long enough and reported?Period not reported. | 0 / 2 |
| How were loss data collected?Interviews, estimates, or method not reported. | 0 / 2 |
| Are OEE, loading time and the loss categories defined explicitly?No definition; metrics are reported as bare numbers. | 0 / 2 |
| Does the loss breakdown account for the total loss it claims to explain?Only selected causes are reported and the total is unknown. | 0 / 2 |
| Is there evidence of selective reporting of favourable results?Observational study, or intervention study that reports baseline and post-intervention data with the same method. | 2 / 2 |
| Are the reported numbers internally consistent?Recomputed totals, shares and OEE factors agree with the reported values within 2 percentage points. | 2 / 2 |
| Could conflicts of interest or the source of the data bias the result?Academic or independent study, or conflicts declared and unrelated to the result. | 2 / 2 |
3Extracted data
Each datum with its classification and the verbatim quote that states it.
| Reported cause | Loss category | Metric | Value | Extraction |
|---|---|---|---|---|
—freezing machineShow verbatim quote (Abstract)The OEE results from these observations were 62.87%. | none | OEE | 62.9 % | Both extractors agreed |
—freezing machineShow verbatim quote (Abstract)A result from the 15 observations showed availability of 96%, performance of 65.84% and quality of 99%. | none | Quality | 99.0 % | Both extractors agreed |
—freezing machineShow verbatim quote (Abstract)A result from the 15 observations showed availability of 96%, performance of 65.84% and quality of 99%. | none | Performance | 65.8 % | Both extractors agreed |
—freezing machineShow verbatim quote (Abstract)A result from the 15 observations showed availability of 96%, performance of 65.84% and quality of 99%. | none | Availability | 96.0 % | Both extractors agreed |
Observation units
- Freezing machine · Refrigeration and freezing · Baseline