1Bibliographic record
- Authors
- Muhammad Ikhsanudin Basri, Rakay Edhiargo Toyosito, Lifia Citra Ramadhanti
- Year
- 2026
- Venue
- UNISTEK
- Country
- Indonesia
- Segment
- Snacks, coffee, tea and other foods
- Process family
- Mixing and formulation
- Study type
- Before/after intervention
- Extraction scope
- Full text
- Size
- 1 plants · 1 lines · 8 machines
- Observation period
- 184 days
- Data collection
- maintenance_records
- Intervention
Show the setting as described by the study
Mesin homogenizer merupakan salah satu peralatan kritis dalam proses produksi Non-Dairy Creamer karena berperan dalam menghasilkan emulsi yang homogen dan stabil.
2Risk of bias
Scored with the rubric of the protocol: 2 low concern, 1 some concerns, 0 high concern.
Total score 12Moderate risk
| Item | Score |
|---|---|
| Is the observed line, machine or plant described well enough to classify its segment, process and equipment?Product, process and equipment are all described. | 2 / 2 |
| Is the observation period long enough and reported?Period reported and at least 30 days of production (or at least 100 recorded events). | 2 / 2 |
| How were loss data collected?Manual logs or maintenance records with unknown completeness. | 1 / 2 |
| Are OEE, loading time and the loss categories defined explicitly?A standard definition is cited but its application is not shown. | 1 / 2 |
| Does the loss breakdown account for the total loss it claims to explain?The reported causes or categories sum to at least 90% of the stated total, or an explicit "other" class closes the balance. | 2 / 2 |
| Is there evidence of selective reporting of favourable results?Intervention study in which baseline and post-intervention periods differ in length or method. | 1 / 2 |
| Are the reported numbers internally consistent?Recomputed totals, shares and OEE factors agree with the reported values within 2 percentage points. | 2 / 2 |
| Could conflicts of interest or the source of the data bias the result?Authors are employees of the plant or of an equipment/software vendor; no declaration. | 1 / 2 |
3Extracted data
Each datum with its classification and the verbatim quote that states it.
| Reported cause | Loss category | Metric | Value | Extraction |
|---|---|---|---|---|
—HomogenizerShow verbatim quote (Table 4)MTTF 4.623,75 Menit | Equipment failure (breakdowns) | Time between events | 4,624 menit | Both extractors agreed |
—HomogenizerShow verbatim quote (Table 4)MTTR 83,63 Menit | Equipment failure (breakdowns) | Mean event duration | 83.6 menit | Both extractors agreed |
—HomogenizerShow verbatim quote (Section 2.1)mesin homogenizer menyumbang downtime sebesar 2.007 menit atau sekitar 69% dari total mechanical downtime yang terjadi pada lini produksi. | Equipment failure (breakdowns) | Lost time | 2,007 menit | Both extractors agreed |
—HomogenizerShow verbatim quote (Table 1)Homogenizer 2.007 24 | Equipment failure (breakdowns) | Number of events | 24.0 events | Both extractors agreed |
Unstable pressurePressure SystemShow verbatim quote (Table 2)Pressure Tidak Stabil Mechanical 100 2 | Equipment failure (breakdowns) | Number of events | 2.00 events | Both extractors agreed |
Unstable pressurePressure SystemShow verbatim quote (Table 2)Pressure Tidak Stabil Mechanical 100 2 | Equipment failure (breakdowns) | Lost time | 100 menit | Both extractors agreed |
Flowmeter erratic readingFlowmeterShow verbatim quote (Table 2)Flowmeter Ngacak Instrument 233 2 | Equipment failure (breakdowns) | Number of events | 2.00 events | Both extractors agreed |
Flowmeter erratic readingFlowmeterShow verbatim quote (Table 2)Flowmeter Ngacak Instrument 233 2 | Equipment failure (breakdowns) | Lost time | 233 menit | Both extractors agreed |
Gasket plunger replacementGasket PlungerShow verbatim quote (Table 2)Ganti Gasket Plunger Mechanical 1.088 13 | Equipment failure (breakdowns) | Number of events | 13.0 events | Both extractors agreed |
Gasket plunger replacementGasket PlungerShow verbatim quote (Table 2)Ganti Gasket Plunger Mechanical 1.088 13 | Equipment failure (breakdowns) | Lost time | 1,088 menit | Both extractors agreed |
Plunger troublePlungerShow verbatim quote (Table 2)Trouble Plunger Mechanical 315 2 | Equipment failure (breakdowns) | Number of events | 2.00 events | Both extractors agreed |
Plunger troublePlungerShow verbatim quote (Table 2)Trouble Plunger Mechanical 315 2 | Equipment failure (breakdowns) | Lost time | 315 menit | Both extractors agreed |
Monoblock troubleMonoblockShow verbatim quote (Table 2)Trouble Monoblock Mechanical 46 1 | Equipment failure (breakdowns) | Number of events | 1.00 events | Both extractors agreed |
Monoblock troubleMonoblockShow verbatim quote (Table 2)Trouble Monoblock Mechanical 46 1 | Equipment failure (breakdowns) | Lost time | 46.0 menit | Both extractors agreed |
Flange leakFlangeShow verbatim quote (Table 2)Flange Bocor Mechanical 225 4 | Equipment failure (breakdowns) | Number of events | 4.00 events | Both extractors agreed |
Flange leakFlangeShow verbatim quote (Table 2)Flange Bocor Mechanical 225 4 | Equipment failure (breakdowns) | Lost time | 225 menit | Both extractors agreed |
—HomogenizerShow verbatim quote (Section 2.1)mesin homogenizer menyumbang downtime sebesar 2.007 menit atau sekitar 69% dari total mechanical downtime yang terjadi pada lini produksi. | Equipment failure (breakdowns) | Share of lost time | 69.0 % | Single extractor |
Gasket plunger replacementGasket PlungerShow verbatim quote (Section 3.2)kerusakan paling dominan terjadi pada gasket plunger dengan kontribusi downtime sebesar 1.088 menit atau 54,21% dari total downtime homogenizer. | Equipment failure (breakdowns) | Share of lost time | 54.2 % | Single extractor |
—HomogenizerShow verbatim quote (Table 3)Persentase Downtime 1,81% | Equipment failure (breakdowns) | Share of planned time | 1.81 % | Single extractor |
—HomogenizerShow verbatim quote (Table 12)Total Downtime 2.007 Menit 610 Menit ↓ 69% | Equipment failure (breakdowns) | Lost time | 610 menit | Single extractor |
—HomogenizerShow verbatim quote (Table 12)Frekuensi Kerusakan 24 Kali 8 Kali ↓ 67% | Equipment failure (breakdowns) | Number of events | 8.00 events | Single extractor |
—HomogenizerShow verbatim quote (Table 12)MTTF 4.623,75 Menit 13.871,25 Menit ↑ 200% | Equipment failure (breakdowns) | Time between events | 13,871 menit | Single extractor |
—HomogenizerShow verbatim quote (Table 12)MTTR 83,63 Menit 76,25 Menit ↓ 8,8% | Equipment failure (breakdowns) | Mean event duration | 76.3 menit | Single extractor |
—BurnerShow verbatim quote (Table 1)Burner 304 2 | Equipment failure (breakdowns) | Lost time | 304 menit | Single extractor |
—BurnerShow verbatim quote (Table 1)Burner 304 2 | Equipment failure (breakdowns) | Number of events | 2.00 events | Single extractor |
—NozzleShow verbatim quote (Table 1)Nozzle 181 1 | Equipment failure (breakdowns) | Lost time | 181 menit | Single extractor |
—NozzleShow verbatim quote (Table 1)Nozzle 181 1 | Equipment failure (breakdowns) | Number of events | 1.00 events | Single extractor |
—ReceptionShow verbatim quote (Table 1)Reception 181 1 | Equipment failure (breakdowns) | Lost time | 181 menit | Single extractor |
—ReceptionShow verbatim quote (Table 1)Reception 181 1 | Equipment failure (breakdowns) | Number of events | 1.00 events | Single extractor |
—Exhaust FanShow verbatim quote (Table 1)Exhaust Fan 168 1 | Equipment failure (breakdowns) | Lost time | 168 menit | Single extractor |
—Exhaust FanShow verbatim quote (Table 1)Exhaust Fan 168 1 | Equipment failure (breakdowns) | Number of events | 1.00 events | Single extractor |
—SifterShow verbatim quote (Table 1)Sifter 30 1 | Equipment failure (breakdowns) | Lost time | 30.0 menit | Single extractor |
—SifterShow verbatim quote (Table 1)Sifter 30 1 | Equipment failure (breakdowns) | Number of events | 1.00 events | Single extractor |
—Inlet FanShow verbatim quote (Table 1)Inlet Fan 23 1 | Equipment failure (breakdowns) | Lost time | 23.0 menit | Single extractor |
—Inlet FanShow verbatim quote (Table 1)Inlet Fan 23 1 | Equipment failure (breakdowns) | Number of events | 1.00 events | Single extractor |
—ScanimaShow verbatim quote (Table 1)Scanima 17 1 | Equipment failure (breakdowns) | Lost time | 17.0 menit | Single extractor |
—ScanimaShow verbatim quote (Table 1)Scanima 17 1 | Equipment failure (breakdowns) | Number of events | 1.00 events | Single extractor |
—Show verbatim quote (Section 1)total downtime mesin mencapai 3.928 menit dengan persentase downtime sebesar 3,54% dari total waktu kerja. | Not classifiable from the report | Lost time | 3,928 menit | Single extractor |
—Show verbatim quote (Section 1)total downtime mesin mencapai 3.928 menit dengan persentase downtime sebesar 3,54% dari total waktu kerja. | Not classifiable from the report | Share of planned time | 3.54 % | Single extractor |
—Show verbatim quote (Section 1)mechanical downtime menjadi penyumbang terbesar dengan nilai 2.911 menit atau sekitar 74,11% dari keseluruhan downtime. | Equipment failure (breakdowns) | Lost time | 2,911 menit | Single extractor |
—Show verbatim quote (Section 1)mechanical downtime menjadi penyumbang terbesar dengan nilai 2.911 menit atau sekitar 74,11% dari keseluruhan downtime. | Equipment failure (breakdowns) | Share of lost time | 74.1 % | Single extractor |
—Show verbatim quote (Section 3.1)total downtime yang terjadi mencapai 2.911 menit dengan frekuensi kerusakan sebanyak 32 kejadian. | Equipment failure (breakdowns) | Number of events | 32.0 events | Single extractor |
Observation units
- Homogenizer · Homogenization · Baseline
- Homogenizer · Homogenization · After intervention
- Burner · Utilities (steam, compressed air, chilled water, power) · Baseline
- Nozzle · Drying · Baseline
- Reception · Whole line or unspecified equipment · Baseline
- Exhaust Fan · Utilities (steam, compressed air, chilled water, power) · Baseline
- Sifter · Separation (centrifugation, filtration, membranes) · Baseline
- Inlet Fan · Utilities (steam, compressed air, chilled water, power) · Baseline
- Scanima · Inspection and checkweighing · Baseline
- All production machines (PT CRM) · Whole line or unspecified equipment · Baseline