It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 54 % of the line's lost time. Reported by 1 of the 76 studies that could observe it (sparse evidence).

What happens

During the blow molding cycle a bottle fails to release cleanly from the mold cavity, either sticking to the mold wall because of inadequate cooling, mold release or part deformation, or detaching prematurely and falling out of the mold or gripper before it is properly transferred. In both cases the mold or take-out mechanism cannot complete its cycle, blocking subsequent cycles until the operator clears the obstruction or repositions the part.

What is done about it

Optimize mold cooling time and mold-release/lubrication to ensure consistent part release, verify alignment and timing of the take-out arm or gripper relative to mold opening, and inspect mold surfaces and ejector pins for wear or damage that causes sticking or premature drop.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.7% [0.1–2.0%]
Expected share of lost time
0.4% [0.1–1.1%]
Share of lost time when present
54% [41–66%]
Studies / units
76 / 96
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.8% [0.1–3.1%]5 studies
  • Soft drinks, bottled water and juices
    1.0% [0.1–3.7%]11 studies
  • Brewing, wine and spirits
    0.8% [0.1–3.2%]0 studies
  • Bakery and pasta
    0.7% [0.1–2.3%]25 studies
  • Meat, poultry and seafood
    0.8% [0.1–3.1%]3 studies
  • Fruit and vegetable processing
    0.8% [0.1–3.2%]3 studies
  • Grain and oilseed milling
    0.8% [0.1–3.0%]0 studies
  • Sugar and confectionery
    0.7% [0.1–2.8%]8 studies
  • Snacks, coffee, tea and other foods
    0.8% [0.1–2.9%]7 studies
  • Animal feed and pet food
    0.8% [0.1–2.8%]6 studies
  • Food manufacturing (unspecified or mixed)
    0.8% [0.1–2.9%]8 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

During the blow molding cycle a bottle fails to release cleanly from the mold cavity, either sticking to the mold wall because of inadequate cooling, mold release or part deformation, or detaching prematurely and falling out of the mold or gripper before it is properly transferred. In both cases the mold or take-out mechanism cannot complete its cycle, blocking subsequent cycles until the operator clears the obstruction or repositions the part.

How it looks in SCADA data

Engineering guidance

Short machine microstops on the blow molding station with cycle time exceeding the nominal mold-open/close window, mold-open or ejector-position fault flags, and a brief drop in bottles-per-cycle count without a maintenance work order. Downstream conveying or filling stations show starvation shortly after the stop is logged.

Countermeasure

Engineering guidance

Optimize mold cooling time and mold-release/lubrication to ensure consistent part release, verify alignment and timing of the take-out arm or gripper relative to mold opening, and inspect mold surfaces and ejector pins for wear or damage that causes sticking or premature drop.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Lost time: 253 menit · as reported: “Bottle Fallen Mold”
    Show verbatim quote
    Bottle Fallen Mold 253
  2. Lost time: 587 menit · as reported: “Bottle Not Ekstrak”
    Show verbatim quote
    Bottle Not Ekstrak 587
  3. Share of lost time: 52.0 % · as reported: “Bottle Not Ekstrak”
    Show verbatim quote
    hasil dari diagram pareto menunjukkan bahwa jenis downtime terbesar adalah Bottle Not Ektrak, yang mencakup 52% dari total waktu henti mesin.