In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 58 % of the line's lost time. Reported by 1 of the 129 studies that could observe it (sparse evidence).
What happens
The line or associated equipment is held in a non-production state while the Clean-in-Place system executes its scheduled wash, rinse and sanitize phases, so no product can be processed until the cycle completes. Extended or abnormal wash durations can push what is normally a planned sanitation stop into an unplanned equipment-related delay.
What is done about it
Schedule CIP cycles during planned non-production windows where possible and optimize phase times and chemical/flow parameters to shorten the cycle without compromising sanitation. Install parallel CIP sets or buffer capacity to decouple cleaning from production, and monitor cycle duration trends to detect and correct abnormally long washes caused by valve, pump or sensor malfunctions.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.5% [0.1–1.5%]
- Expected share of lost time
- 0.3% [0.1–0.9%]
- Share of lost time when present
- 58% [47–69%]
- Studies / units
- 129 / 163
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.6% [0.1–2.2%]13 studies
- Soft drinks, bottled water and juices0.5% [0.1–1.9%]27 studies
- Brewing, wine and spirits0.6% [0.1–2.3%]11 studies
- Bakery and pasta0.6% [0.1–2.0%]24 studies
- Meat, poultry and seafood0.6% [0.1–2.2%]9 studies
- Fruit and vegetable processing0.7% [0.1–2.6%]7 studies
- Grain and oilseed milling0.6% [0.1–2.3%]6 studies
- Sugar and confectionery0.6% [0.1–2.4%]9 studies
- Snacks, coffee, tea and other foods0.6% [0.1–2.3%]5 studies
- Animal feed and pet food0.6% [0.1–2.2%]7 studies
- Food manufacturing (unspecified or mixed)0.9% [0.1–3.4%]11 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceThe line or associated equipment is held in a non-production state while the Clean-in-Place system executes its scheduled wash, rinse and sanitize phases, so no product can be processed until the cycle completes. Extended or abnormal wash durations can push what is normally a planned sanitation stop into an unplanned equipment-related delay.
How it looks in SCADA data
Engineering guidanceCIP controller or line state log shows a transition into wash/rinse/sanitize/drain phases with the downstream line in a stopped or standby state; MES records a downtime event tagged to the CIP system with a logged duration, and outlier events with unusually long durations appear as the recorded maxima. Flow, temperature and conductivity trends on the CIP skid confirm the active phase sequence during the stop.
Countermeasure
Engineering guidanceSchedule CIP cycles during planned non-production windows where possible and optimize phase times and chemical/flow parameters to shorten the cycle without compromising sanitation. Install parallel CIP sets or buffer capacity to decouple cleaning from production, and monitor cycle duration trends to detect and correct abnormally long washes caused by valve, pump or sensor malfunctions.
4Sources
- Total Productive Maintenance Model applying SMED and FMEA to increase the overall efficiency of equipment (OEE) in the food sector (2021)Open sourceLost time: 16.0 h · as reported: “CIP wash stop”
Show verbatim quote
The stop that represents the largest proportion is the CIP wash stop, which represents a stop time of approximately 16 hours.
- Total Productive Maintenance Model applying SMED and FMEA to increase the overall efficiency of equipment (OEE) in the food sector (2021)Open sourceLost time: 26.0 h · as reported: “CIP wash stop (maximum recorded)”
Show verbatim quote
the plant management recorded washing times that exceeded the planned one, occupying a maximum of 26 stop-page hours