Process defects (scrap and rework)

Doser calibration drift

Process defects (scrap and rework)QualityFilling

In short

It appears in fewer than 1 of every 100 lines studied.

When it appears, it takes on average about 48 % of the line's lost time. Reported by 0 of the 120 studies that could observe it (sparse evidence).

What happens

The dosing unit loses calibration accuracy over time because of mechanical wear, valve or piston leakage, or changes in product viscosity, pressure and temperature, so the volume or weight actually dispensed drifts away from the programmed setpoint. Units are produced within the normal cycle but fall outside the target fill specification at first pass.

What is done about it

Establish a scheduled calibration and preventive maintenance routine for the dosing components, and install closed-loop feedback from checkweighers or flow meters so the control system can auto-correct the dosing setpoint before product falls out of tolerance.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.4% [0.1–1.0%]
Expected share of lost time
0.2% [0.0–0.5%]
Share of lost time when present
48% [36–60%]
Studies / units
120 / 162
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.4% [0.0–1.5%]18 studies
  • Soft drinks, bottled water and juices
    0.4% [0.0–1.3%]44 studies
  • Brewing, wine and spirits
    0.4% [0.0–1.5%]16 studies
  • Bakery and pasta
    0.4% [0.0–1.6%]0 studies
  • Meat, poultry and seafood
    0.4% [0.0–1.6%]6 studies
  • Fruit and vegetable processing
    0.4% [0.0–1.7%]4 studies
  • Grain and oilseed milling
    0.4% [0.0–1.7%]6 studies
  • Sugar and confectionery
    0.4% [0.0–1.7%]3 studies
  • Snacks, coffee, tea and other foods
    0.4% [0.0–1.7%]6 studies
  • Animal feed and pet food
    0.4% [0.0–1.7%]4 studies
  • Food manufacturing (unspecified or mixed)
    0.4% [0.0–1.6%]13 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

The dosing unit loses calibration accuracy over time because of mechanical wear, valve or piston leakage, or changes in product viscosity, pressure and temperature, so the volume or weight actually dispensed drifts away from the programmed setpoint. Units are produced within the normal cycle but fall outside the target fill specification at first pass.

How it looks in SCADA data

Engineering guidance

Checkweigher or fill-level inspection data show a gradual trend of weights or volumes drifting away from the target band without an associated machine stop, often followed by a manual recalibration event that resets the trend. Reject counters for underfill or overfill rise progressively while the doser continues to cycle normally.

Countermeasure

Engineering guidance

Establish a scheduled calibration and preventive maintenance routine for the dosing components, and install closed-loop feedback from checkweighers or flow meters so the control system can auto-correct the dosing setpoint before product falls out of tolerance.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Defect rate: 0.800 % · as reported: “Calibración dosificador”
    Show verbatim quote
    la reducción de dosificado se modificó de 1.1% excedente en el total de botellas a 0.8% con lo cual se dio un ahorro dentro del marco de necesidades y planteamiento del problema.
  2. Defect rate: 1.10 % · as reported: “Calibración dosificador”
    Show verbatim quote
    la reducción de dosificado se modificó de 1.1% excedente en el total de botellas a 0.8% con lo cual se dio un ahorro dentro del marco de necesidades y planteamiento del problema.