Unspecified fermentation equipment failure
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 58 % of the line's lost time. Reported by 1 of the 29 studies that could observe it (sparse evidence).
What happens
A component of the fermentation equipment (vessel, agitator, valve, instrumentation, or associated drive or control element) loses or degrades its intended function, forcing an unplanned stop of the fermenter until the fault is diagnosed and repaired. The underlying failure mode is not specified in the source report, so it may involve mechanical, electrical, pneumatic, hydraulic, or control-system elements of the tank and its auxiliaries.
What is done about it
Apply condition-based and preventive maintenance to fermenter vessels, agitators, valves, and instrumentation, and use SCADA fault logs to identify recurring failure modes so that generic fault codes can be reclassified into specific, actionable categories over time. Maintain critical spares and troubleshooting procedures to shorten repair time once a failure is detected.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 1.0% [0.2–3.3%]
- Expected share of lost time
- 0.6% [0.1–1.9%]
- Share of lost time when present
- 58% [46–68%]
- Studies / units
- 29 / 33
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products1.7% [0.2–6.4%]8 studies
- Soft drinks, bottled water and juices1.3% [0.1–5.1%]1 study
- Brewing, wine and spirits1.3% [0.1–5.2%]0 studies
- Bakery and pasta1.2% [0.1–4.9%]1 study
- Meat, poultry and seafood1.2% [0.1–4.7%]0 studies
- Fruit and vegetable processing1.2% [0.1–4.7%]2 studies
- Grain and oilseed milling1.2% [0.1–5.0%]0 studies
- Sugar and confectionery1.2% [0.1–4.7%]3 studies
- Snacks, coffee, tea and other foods1.2% [0.1–4.9%]3 studies
- Animal feed and pet food1.2% [0.1–4.6%]4 studies
- Food manufacturing (unspecified or mixed)1.2% [0.1–4.5%]7 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceA component of the fermentation equipment (vessel, agitator, valve, instrumentation, or associated drive or control element) loses or degrades its intended function, forcing an unplanned stop of the fermenter until the fault is diagnosed and repaired. The underlying failure mode is not specified in the source report, so it may involve mechanical, electrical, pneumatic, hydraulic, or control-system elements of the tank and its auxiliaries.
How it looks in SCADA data
Engineering guidanceSCADA/MES records a fermenter or fermentation-area asset entering a fault or downtime state outside the scheduled batch sequence, with an unplanned stop duration long enough to require maintenance intervention; process variables such as agitator speed, temperature, pressure or pH may show an abrupt deviation or flatline coincident with the stop, and an associated alarm or fault code is typically logged without a specific root-cause tag.
Countermeasure
Engineering guidanceApply condition-based and preventive maintenance to fermenter vessels, agitators, valves, and instrumentation, and use SCADA fault logs to identify recurring failure modes so that generic fault codes can be reclassified into specific, actionable categories over time. Maintain critical spares and troubleshooting procedures to shorten repair time once a failure is detected.
4Sources
- Evaluation of maintenance management through the overall equipment effectiveness of a yogurt production line in a medium-sized Italian company (2015)Open sourceTime between events: 190 min · as reported: “failure”
Show verbatim quote
in the production line there is a failure every 190 minutes that needs about five minutes to repair

