foratvise
Get Started
Equipment failure (breakdowns)

Unspecified fermentation equipment failure

Equipment failure (breakdowns)AvailabilityFermentation

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 58 % of the line's lost time. Reported by 1 of the 29 studies that could observe it (sparse evidence).

What happens

A component of the fermentation equipment (vessel, agitator, valve, instrumentation, or associated drive or control element) loses or degrades its intended function, forcing an unplanned stop of the fermenter until the fault is diagnosed and repaired. The underlying failure mode is not specified in the source report, so it may involve mechanical, electrical, pneumatic, hydraulic, or control-system elements of the tank and its auxiliaries.

What is done about it

Apply condition-based and preventive maintenance to fermenter vessels, agitators, valves, and instrumentation, and use SCADA fault logs to identify recurring failure modes so that generic fault codes can be reclassified into specific, actionable categories over time. Maintain critical spares and troubleshooting procedures to shorten repair time once a failure is detected.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
1.0% [0.2–3.3%]
Expected share of lost time
0.6% [0.1–1.9%]
Share of lost time when present
58% [46–68%]
Studies / units
29 / 33
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    1.7% [0.2–6.4%]8 studies
  • Soft drinks, bottled water and juices
    1.3% [0.1–5.1%]1 study
  • Brewing, wine and spirits
    1.3% [0.1–5.2%]0 studies
  • Bakery and pasta
    1.2% [0.1–4.9%]1 study
  • Meat, poultry and seafood
    1.2% [0.1–4.7%]0 studies
  • Fruit and vegetable processing
    1.2% [0.1–4.7%]2 studies
  • Grain and oilseed milling
    1.2% [0.1–5.0%]0 studies
  • Sugar and confectionery
    1.2% [0.1–4.7%]3 studies
  • Snacks, coffee, tea and other foods
    1.2% [0.1–4.9%]3 studies
  • Animal feed and pet food
    1.2% [0.1–4.6%]4 studies
  • Food manufacturing (unspecified or mixed)
    1.2% [0.1–4.5%]7 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

A component of the fermentation equipment (vessel, agitator, valve, instrumentation, or associated drive or control element) loses or degrades its intended function, forcing an unplanned stop of the fermenter until the fault is diagnosed and repaired. The underlying failure mode is not specified in the source report, so it may involve mechanical, electrical, pneumatic, hydraulic, or control-system elements of the tank and its auxiliaries.

How it looks in SCADA data

Engineering guidance

SCADA/MES records a fermenter or fermentation-area asset entering a fault or downtime state outside the scheduled batch sequence, with an unplanned stop duration long enough to require maintenance intervention; process variables such as agitator speed, temperature, pressure or pH may show an abrupt deviation or flatline coincident with the stop, and an associated alarm or fault code is typically logged without a specific root-cause tag.

Countermeasure

Engineering guidance

Apply condition-based and preventive maintenance to fermenter vessels, agitators, valves, and instrumentation, and use SCADA fault logs to identify recurring failure modes so that generic fault codes can be reclassified into specific, actionable categories over time. Maintain critical spares and troubleshooting procedures to shorten repair time once a failure is detected.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Time between events: 190 min · as reported: “failure”
    Show verbatim quote
    in the production line there is a failure every 190 minutes that needs about five minutes to repair