Filler timing worm/synchronization fault
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 57 % of the line's lost time. Reported by 1 of the 120 studies that could observe it (sparse evidence).
What happens
The worm gear (timing screw) that indexes containers under the filling valves loses correct phase relative to the valve/turret drive because of mechanical wear, backlash, loose fasteners or an incorrectly set cam/gear train. The resulting mis-timing causes valves to open or close out of register with the container position, producing mechanical interference, spillage or jamming that stops the machine until the drive is realigned.
What is done about it
Perform periodic inspection and readjustment of the worm gear and valve-drive timing, tightening fasteners and resetting cam/gear phase to specification, and replace worn gear, bushing or bearing components proactively. Include timing-chain or gear-train alignment checks in the preventive-maintenance plan and verify synchronization with the container-indexing reference after any adjustment.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.6% [0.1–1.6%]
- Expected share of lost time
- 0.3% [0.1–0.9%]
- Share of lost time when present
- 57% [46–68%]
- Studies / units
- 120 / 162
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.6% [0.1–2.3%]18 studies
- Soft drinks, bottled water and juices0.5% [0.1–1.6%]44 studies
- Brewing, wine and spirits0.6% [0.1–2.2%]16 studies
- Bakery and pasta0.7% [0.1–2.7%]0 studies
- Meat, poultry and seafood0.7% [0.1–2.4%]6 studies
- Fruit and vegetable processing0.7% [0.1–2.6%]4 studies
- Grain and oilseed milling1.0% [0.1–3.6%]6 studies
- Sugar and confectionery0.7% [0.1–2.5%]3 studies
- Snacks, coffee, tea and other foods0.7% [0.1–2.5%]6 studies
- Animal feed and pet food0.7% [0.1–2.6%]4 studies
- Food manufacturing (unspecified or mixed)0.6% [0.1–2.4%]13 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceThe worm gear (timing screw) that indexes containers under the filling valves loses correct phase relative to the valve/turret drive because of mechanical wear, backlash, loose fasteners or an incorrectly set cam/gear train. The resulting mis-timing causes valves to open or close out of register with the container position, producing mechanical interference, spillage or jamming that stops the machine until the drive is realigned.
How it looks in SCADA data
Engineering guidanceSCADA/MES shows discrete equipment-failure stops on the filler logged with mechanical/timing fault codes, often preceded by recurring short stops or jam alarms on the same station as wear progresses. Encoder or position-sensor data for the worm/valve drive shows phase drift or out-of-tolerance deviation relative to the container-indexing reference just before the stop.
Countermeasure
Engineering guidancePerform periodic inspection and readjustment of the worm gear and valve-drive timing, tightening fasteners and resetting cam/gear phase to specification, and replace worn gear, bushing or bearing components proactively. Include timing-chain or gear-train alignment checks in the preventive-maintenance plan and verify synchronization with the container-indexing reference after any adjustment.
4Sources
- Share of lost time: 50.7 % · as reported: “synching and worm adjustment issues”
Show verbatim quote
The filling machine caused 50.7% of downtime, primarily due to synching and worm adjustment issues.