foratvise
Get Started
Equipment failure (breakdowns)

Bottle inspection machine failure

Equipment failure (breakdowns)AvailabilityInspection and checkweighing

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 58 % of the line's lost time. Reported by 1 of the 79 studies that could observe it (sparse evidence).

What happens

The bottle inspection machine stops due to degradation or loss of function in its mechanical, electrical, pneumatic or control components, such as camera or sensor malfunction, reject actuator jamming, drive or encoder faults, or lighting system failure. These faults prevent the unit from performing empty or filled bottle inspection and require a maintenance intervention to restore function.

What is done about it

Apply preventive and condition-based maintenance to inspection cameras, sensors, lighting and reject actuators, including regular calibration and cleaning schedules. Maintain critical spare parts on hand and implement early-warning diagnostics on drives and control electronics to detect degradation before a functional failure occurs.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.7% [0.1–1.9%]
Expected share of lost time
0.4% [0.1–1.1%]
Share of lost time when present
58% [46–68%]
Studies / units
79 / 101
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.8% [0.1–3.0%]10 studies
  • Soft drinks, bottled water and juices
    0.7% [0.1–2.3%]26 studies
  • Brewing, wine and spirits
    1.1% [0.1–4.0%]12 studies
  • Bakery and pasta
    0.9% [0.1–3.3%]0 studies
  • Meat, poultry and seafood
    0.8% [0.1–3.3%]4 studies
  • Fruit and vegetable processing
    0.8% [0.1–3.0%]4 studies
  • Grain and oilseed milling
    0.8% [0.1–3.2%]3 studies
  • Sugar and confectionery
    0.8% [0.1–3.1%]3 studies
  • Snacks, coffee, tea and other foods
    0.8% [0.1–2.9%]4 studies
  • Animal feed and pet food
    0.8% [0.1–3.1%]4 studies
  • Food manufacturing (unspecified or mixed)
    0.8% [0.1–2.8%]9 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

The bottle inspection machine stops due to degradation or loss of function in its mechanical, electrical, pneumatic or control components, such as camera or sensor malfunction, reject actuator jamming, drive or encoder faults, or lighting system failure. These faults prevent the unit from performing empty or filled bottle inspection and require a maintenance intervention to restore function.

How it looks in SCADA data

Engineering guidance

SCADA/MES logs show the inspection machine entering a fault or downtime state with associated alarm codes (sensor fault, camera error, reject mechanism jam, drive fault), with stop durations long enough to be flagged as a failure event. Upstream filling or capping stations show blocking and downstream packaging shows starvation while the inspector is down, and reject counters may freeze or spike abnormally before the stop.

Countermeasure

Engineering guidance

Apply preventive and condition-based maintenance to inspection cameras, sensors, lighting and reject actuators, including regular calibration and cleaning schedules. Maintain critical spare parts on hand and implement early-warning diagnostics on drives and control electronics to detect degradation before a functional failure occurs.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Lost time: 485 min · as reported: “BIM”
    Show verbatim quote
    Total 2540 485 500 560 450 265 225 240 220 5485 224940 2.44%
  2. Number of events: 21.0 events · as reported: “BIM”
    Show verbatim quote
    Total 61 21 24 22 17 7 11 10 8 181