Bottle inspection machine failure
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 58 % of the line's lost time. Reported by 1 of the 79 studies that could observe it (sparse evidence).
What happens
The bottle inspection machine stops due to degradation or loss of function in its mechanical, electrical, pneumatic or control components, such as camera or sensor malfunction, reject actuator jamming, drive or encoder faults, or lighting system failure. These faults prevent the unit from performing empty or filled bottle inspection and require a maintenance intervention to restore function.
What is done about it
Apply preventive and condition-based maintenance to inspection cameras, sensors, lighting and reject actuators, including regular calibration and cleaning schedules. Maintain critical spare parts on hand and implement early-warning diagnostics on drives and control electronics to detect degradation before a functional failure occurs.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.7% [0.1–1.9%]
- Expected share of lost time
- 0.4% [0.1–1.1%]
- Share of lost time when present
- 58% [46–68%]
- Studies / units
- 79 / 101
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.8% [0.1–3.0%]10 studies
- Soft drinks, bottled water and juices0.7% [0.1–2.3%]26 studies
- Brewing, wine and spirits1.1% [0.1–4.0%]12 studies
- Bakery and pasta0.9% [0.1–3.3%]0 studies
- Meat, poultry and seafood0.8% [0.1–3.3%]4 studies
- Fruit and vegetable processing0.8% [0.1–3.0%]4 studies
- Grain and oilseed milling0.8% [0.1–3.2%]3 studies
- Sugar and confectionery0.8% [0.1–3.1%]3 studies
- Snacks, coffee, tea and other foods0.8% [0.1–2.9%]4 studies
- Animal feed and pet food0.8% [0.1–3.1%]4 studies
- Food manufacturing (unspecified or mixed)0.8% [0.1–2.8%]9 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceThe bottle inspection machine stops due to degradation or loss of function in its mechanical, electrical, pneumatic or control components, such as camera or sensor malfunction, reject actuator jamming, drive or encoder faults, or lighting system failure. These faults prevent the unit from performing empty or filled bottle inspection and require a maintenance intervention to restore function.
How it looks in SCADA data
Engineering guidanceSCADA/MES logs show the inspection machine entering a fault or downtime state with associated alarm codes (sensor fault, camera error, reject mechanism jam, drive fault), with stop durations long enough to be flagged as a failure event. Upstream filling or capping stations show blocking and downstream packaging shows starvation while the inspector is down, and reject counters may freeze or spike abnormally before the stop.
Countermeasure
Engineering guidanceApply preventive and condition-based maintenance to inspection cameras, sensors, lighting and reject actuators, including regular calibration and cleaning schedules. Maintain critical spare parts on hand and implement early-warning diagnostics on drives and control electronics to detect degradation before a functional failure occurs.
4Sources
- Study on Preventive Maintenance Strategies of Filling Equipment Based on Reliability-Cantered Maintenance (2021)Open sourceLost time: 485 min · as reported: “BIM”
Show verbatim quote
Total 2540 485 500 560 450 265 225 240 220 5485 224940 2.44%
- Study on Preventive Maintenance Strategies of Filling Equipment Based on Reliability-Cantered Maintenance (2021)Open sourceNumber of events: 21.0 events · as reported: “BIM”
Show verbatim quote
Total 61 21 24 22 17 7 11 10 8 181