foratvise
Get Started
Equipment failure (breakdowns)

Mixer equipment failure

Equipment failure (breakdowns)AvailabilityMixing and blending

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 58 % of the line's lost time. Reported by 1 of the 31 studies that could observe it (sparse evidence).

What happens

Unplanned stoppage of the mixer arises from mechanical or electrical degradation of components such as the drive motor, gearbox, agitator shaft, bearings or seals, which lose function under the loads and duty cycles of continuous or batch mixing. The failure forces the mixer out of production until maintenance personnel diagnose and repair the faulty component.

What is done about it

Typical countermeasures include a preventive and condition-based maintenance program with vibration, temperature and current monitoring on the drive train, scheduled replacement of bearings and seals before end of life, and lubrication and alignment checks. Where criticality justifies it, standby capacity or rapid-swap components reduce the production impact of a failure.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
1.0% [0.2–3.0%]
Expected share of lost time
0.6% [0.1–1.7%]
Share of lost time when present
58% [47–68%]
Studies / units
31 / 40
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    1.2% [0.1–4.5%]6 studies
  • Soft drinks, bottled water and juices
    1.2% [0.1–4.8%]2 studies
  • Brewing, wine and spirits
    1.2% [0.1–4.9%]0 studies
  • Bakery and pasta
    1.1% [0.1–4.0%]2 studies
  • Meat, poultry and seafood
    1.2% [0.1–4.8%]1 study
  • Fruit and vegetable processing
    1.2% [0.1–4.6%]2 studies
  • Grain and oilseed milling
    1.2% [0.1–5.0%]0 studies
  • Sugar and confectionery
    1.2% [0.1–4.6%]3 studies
  • Snacks, coffee, tea and other foods
    1.1% [0.1–4.3%]3 studies
  • Animal feed and pet food
    1.6% [0.2–6.0%]5 studies
  • Food manufacturing (unspecified or mixed)
    1.1% [0.1–4.4%]7 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

Unplanned stoppage of the mixer arises from mechanical or electrical degradation of components such as the drive motor, gearbox, agitator shaft, bearings or seals, which lose function under the loads and duty cycles of continuous or batch mixing. The failure forces the mixer out of production until maintenance personnel diagnose and repair the faulty component.

How it looks in SCADA data

Engineering guidance

SCADA/MES data show the mixer transitioning to a fault or stopped machine state with an associated alarm code (overload, overcurrent, high vibration, high temperature or torque deviation), and motor current or torque signals deviating from the normal mixing profile before the trip. Upstream and downstream equipment subsequently show starvation or blocking state durations correlated with the mixer downtime.

Countermeasure

Engineering guidance

Typical countermeasures include a preventive and condition-based maintenance program with vibration, temperature and current monitoring on the drive train, scheduled replacement of bearings and seals before end of life, and lubrication and alignment checks. Where criticality justifies it, standby capacity or rapid-swap components reduce the production impact of a failure.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Lost time: 0.195 Kg.h-1 · as reported: “Mixing (all products)”
    Show verbatim quote
    1Mixing 2.50 0.078 ± 0.020 0.195 ± 0.050 Kg 2.43