Mixing and blending
Batch blending of miscible liquids in a baffled stirred tank
In short
Mixing and blending can use at most 97 of every 100 planned hours. The rest goes to limits no plant can avoid.
- 97usable at most
- 3are a physical limit
The three limits that set it
Running time: up to 98 %
The rest are stops imposed by physics or by regulation: cleaning, changeovers, defrosting.
Speed: up to 100 %
How close to its maximum speed it can run without damaging the product or the equipment.
Good product: up to 98 %
Some product falls outside specification even with the process well under control.
Technical detail
Uncertainty intervals, physical models per station and sources, for anyone who wants to check each figure.
1Scenario
A beverage or dairy formulation is prepared in a 10 m3 baffled, flat-bottomed cylindrical tank with liquid height equal to the tank diameter and a single axial-flow impeller. A concentrate (syrup, flavour base) is dosed into water or milk and blended until the composition is uniform within specification; the batch is then pumped out, the tank drains by gravity and the next batch is filled. Incompatible products are separated by a cleaning-in-place.
2Results
- Tank diameter (liquid height equal to diameter)2.34 m
- Impeller speed at the installed power per volume106 [72–199] 1/min
- Impeller Reynolds number724,267 [333,147–1,214,477]
- Impeller tip speed4.26 [3.29–6.42] m/s
- Blend time to 95 % homogeneity with the large impeller (D/T of the best geometry)21.7 [16.0–26.3] s
- Blend time to 95 % homogeneity with the installed impeller24.9 [17.9–30.9] s
- TheoreticalMinimum blend time to the specification homogeneity (large impeller)47.0 [31.9–57.3] s
- TypicalBlend time to the specification homogeneity (installed impeller)54.0 [36.2–67.2] s
- Batch cycle time with the large impeller (fill + blend + discharge + drainage; declared pump flows, no ceiling)45.8 [31.1–59.0] min
- Batch cycle time with the installed impeller (declared pump flows, no ceiling)45.9 [31.2–59.1] min
- Blended volume per hour with the large impeller (declared pump flows: a scenario value, no ceiling)13.1 [10.2–19.3] m³/h
- TypicalBlended volume per hour with the installed impeller13.1 [10.1–19.3] m³/h
- TheoreticalThermodynamic minimum work of blending (ideal mixing is spontaneous)0 kJ/kg
- Blending energy to specification with the large impeller (declared geometry, not a documented BAT)0.00905 [0.00587–0.01690] kJ/kg
- TypicalBlending energy to specification with the installed impeller0.0104 [0.0068–0.0199] kJ/kg
- Initial coefficient of variation of the composition (segregated components)2.23 [1.75–2.94]
- Residual coefficient of variation at the end of the blend0.00333 [0.00180–0.00655]
- TheoreticalMaximum OEE quality factor (share of batches within the composition specification)0.984 [0.869–0.997]
- Mean thickness of the wall film after drainage (Jeffreys)22.6 [15.1–42.1] micrometer
- Liquid left on the wetted walls after drainage0.483 [0.324–0.901] L
- TheoreticalMaximum yield (wall film after drainage only)0.999952 [0.999910–0.999968]
- TypicalYield with heel and line hold-up (declared scenario)0.9970 [0.9941–0.9988]
- TheoreticalMaximum availability (daily minimum cleaning)0.9844 [0.9791–0.9886]
- Availability with declared changeovers (minimum cleaning between incompatible products)0.942 [0.876–0.974]
- TypicalAvailability with typical cleanings between incompatible products0.859 [0.701–0.931]
- TheoreticalPerformance factor against the physics-limited cycle1.00
- TheoreticalPhysics-bounded OEE0.968 [0.855–0.983]
- OEE with declared changeovers0.927 [0.811–0.966]
3Ceilings per dimension
- Theoretical
- Best available technique
- Best documented
- Typical
- TheoreticalMinimum blend time to the specification homogeneity (large impeller)47.0 [31.9–57.3] s
- TypicalBlend time to the specification homogeneity (installed impeller)54.0 [36.2–67.2] s
- TypicalBlended volume per hour with the installed impeller13.1 [10.1–19.3] m³/h
- TheoreticalThermodynamic minimum work of blending (ideal mixing is spontaneous)0 kJ/kg
- TheoreticalDOE bandwidth study: products without significant chemical reactions have a zero thermodynamic minimum energy intensity · Benchmark0 kJ/kg
- TypicalBlending energy to specification with the installed impeller0.0104 [0.0068–0.0199] kJ/kg
- TheoreticalMaximum OEE quality factor (share of batches within the composition specification)0.984 [0.869–0.997]
- TheoreticalMaximum yield (wall film after drainage only)0.999952 [0.999910–0.999968]
- TypicalYield with heel and line hold-up (declared scenario)0.9970 [0.9941–0.9988]
- TheoreticalMaximum availability (daily minimum cleaning)0.9844 [0.9791–0.9886]
- TypicalAvailability with typical cleanings between incompatible products0.859 [0.701–0.931]
- TheoreticalPerformance factor against the physics-limited cycle1.00
- TheoreticalPhysics-bounded OEE0.968 [0.855–0.983]
4Loss cascade
- TheoreticalTypicalCycle or residence time47.0 [31.9–57.3] s → 54.0 [36.2–67.2] s (gap 6.99 s)
The time ceilings are blend times to the specification homogeneity; the batch cycle, dominated by the declared fill and discharge pump flows, carries no ceiling. At equal power per volume the blend time scales as (T/D)^(1/3) and does not depend on the impeller type, so a small impeller costs time even though it turns faster. Real blends add what the correlation excludes: density and viscosity differences between concentrate and diluent (a heavy syrup sinks and must be lifted by the flow, which can lengthen the blend several times), dosing while the impeller is uncovered, dead zones under the impeller, and the time of sampling and laboratory release.
- TheoreticalTypicalEnergy per unit of product0 kJ/kg → 0.0104 [0.0068–0.0199] kJ/kg (gap 0.0104 kJ/kg)
Mixing ideal liquids is spontaneous: the Gibbs energy of mixing is negative, so no work is thermodynamically required. Work is needed only to make it fast: the agitator dissipates its whole power as heat by viscous friction. Blending energy is the power times the blend time; at equal power per volume a larger impeller reaches the same homogeneity sooner and therefore spends less energy. The installed impeller needs (T/D)^(1/3) more time at the same power, hence more energy. In practice the agitator often runs during the whole fill and discharge, not only for the blend time, and motor and gearbox losses are added; both multiply the energy without improving the blend.
- TheoreticalTypicalYield0.999952 [0.999910–0.999968] → 0.9970 [0.9941–0.9988] (gap 0.00300)
Physics leaves only the liquid film that clings to the wetted walls after gravity drainage, a few tens of micrometres thick and a fraction of a litre for a 10 m3 tank. The heel left below the outlet, the liquid in the pump, valves and pipes, and the first rinse that pushes the product out are technology: their volume depends on the tank bottom, the outlet position and the line layout, and dominates the loss. Pigging or air push-out of lines and sloped or dished bottoms close this gap.
5Physics-bounded OEE
- Loading time (ideal)1.000
- Availabilityfactor 0.9844 [0.9791–0.9886]0.984 (−0.016)
- Performancefactor 1.000.984 (−0.000)
- Qualityfactor 0.984 [0.869–0.997]0.968 (−0.016)
- Physics-bounded OEE0.968 [0.855–0.983]
6Full derivation
Scope. A beverage or dairy formulation is blended in a 10 m³ baffled, flat-bottomed cylindrical tank with liquid height equal to the tank diameter () and one axial-flow impeller. A concentrate (syrup, flavour base) is dosed into water or milk and blended until the composition is uniform within specification; the batch is pumped out, the tank drains by gravity and the next batch is filled. Symbols and their values, units, uncertainty distributions and sources are listed in the parameter table generated from config/physics/mixing.yaml. Numbers quoted here are point values; the output table gives the Monte Carlo intervals.
1. Mass balance — maximum yield
Blending neither creates nor destroys mass: everything dosed into the tank leaves it as product, except what stays behind when the tank is emptied. The physics of emptying sets a lower bound on that residue: a viscous liquid draining down a vertical wall leaves a film whose thickness decreases with time but never vanishes.
Wall film after drainage (Jeffreys). For a Newtonian liquid of viscosity and density draining under gravity from a vertical wall, the lubrication balance between weight and viscous shear gives a local film thickness, a time after the start of drainage and a distance below the top of the wetted wall,
Averaging over the wetted height :
for a drainage time = 300 s and = 1.5 mPa s. The wetted area is the wall plus the bottom, = 21 m²; the bottom is given the same mean thickness (a declared simplification). The hold-up and the theoretical yield are
Technology. The heel below the outlet and the liquid in pump, valves and pipes (, scenario 30 L) are properties of the installation, not of physics: . The BAT reference document records that product is lost because equipment is difficult to empty before cleaning or a batch change, and reports a normal product loss of 0.5–1.5% for whole dairy plants; that boundary is wider than one tank and is not compared numerically.
2. Energy balance — minimum energy per unit of product
Thermodynamic minimum. For an ideal solution the Gibbs energy of mixing is
where and are the amount and mole fraction of each component and the molar gas constant. Every is negative, so is negative for any composition: mixing is spontaneous and could, in principle, deliver work rather than consume it. The thermodynamic minimum work of blending is therefore zero (taking no credit for the recoverable work). Heats of mixing of aqueous sugar solutions are small and are neglected. This agrees with the DOE bandwidth study, which gives a zero thermodynamic minimum to products without significant chemical reactions.
Why energy is spent anyway. Molecular diffusion alone would take far longer than any production schedule: with a diffusion coefficient of order m²/s, the diffusion time over a metre is of the order of decades. The agitator buys speed: its shaft power is entirely dissipated as heat by viscous friction while it stretches and folds the fluid until diffusion can finish the job at small scales. The blending energy per kilogram is
0.0090 kJ/kg with the large impeller and 0.0104 kJ/kg with the installed impeller at 200 W/m³ (Section 3). The installed value is the typical energy ceiling and the theoretical one is zero; the large-impeller value uses a declared geometry, not a documented best available technique, so it is reported without a ceiling label.
3. Rate-limiting step — blend time and minimum batch cycle
Blend-time correlation. In the turbulent regime the time to reach 95% homogeneity, , of a baffled tank with is correlated by Grenville's equation (as presented by Grenville and Nienow, 2003, and Nienow, 1997):
where is the impeller speed, the impeller diameter, the tank diameter and the turbulent power number of the impeller, which links power and speed through
Blend time at given power. Eliminating between the two equations:
The power number cancels: at equal power input the blend time does not depend on the impeller type, only on the geometry and the power. Because , this is equivalent to : four times the power shortens the blend by ; a larger impeller at the same power blends faster. With = 10 m³ ( = 2.34 m) and = 200 W/m³, = 24.9 s with = 0.33 and 21.7 s with = 0.50. The impeller speed (106 min⁻¹), Reynolds number and tip speed (4.3 m/s) are reported to check that the flow is fully turbulent, as the correlation requires.
From 95% to the specification. Treat the decay of non-uniformity as first order: the normalised deviation from the final composition decays as . Since it falls from 1 to 0.05 at , . The coefficient of variation (CoV) of composition across the tank starts, for a concentrate of volume fraction still segregated from the diluent, at
and . The blend is stopped when the residual CoV is the composition tolerance divided by a factor (scenario 3), so that non-uniformity contributes little to the batch error:
Minimum batch cycle. Filling and discharge are limited by the pumps (, ) and the tank must drain for before the next batch:
With 20-minute fills and discharges the blend is a small share of the cycle; the pumps, not the agitator, are the main rate lever. Because the cycle and the rate are set by the declared pump flows, they are scenario values passed through a formula and carry no ceiling label; the physics ceiling of the time dimension is the blend time to specification. Under the common batch convention, fill, discharge and drainage belong to the ideal cycle, so they act through the performance factor (here 1, because the capable process needs no longer cycle) and not through availability. Drainage time trades cycle time against yield: the film thickness falls only as .
4. Process capability — quality ceiling
The composition of a finished batch deviates from target for two independent reasons: the residual non-uniformity at the end of the blend () and the error of the dosed quantities (relative standard deviation , load cells or flow meters), which no amount of mixing can remove. With both normally distributed, the relative composition error has standard deviation
and the share of batches within the tolerance is
with the standard normal distribution function. A batch outside tolerance is corrected rather than destroyed, but it is not right first time and counts as a quality loss. Blending longer cannot raise above : beyond a few the ceiling is set by dosing accuracy.
5. Unavoidable stops — maximum availability
Milk equipment must be cleaned at least once each day used. The minimum duration of the cleaning, , is taken through a parameter link from the cleaning model (output cip_time_min: the physical minimum of the kinetic and displacement phases plus declared hold times). That model is valid for recirculated pipe circuits; the spray cleaning of the tank interior is outside its validity, so the linked duration is a lower bound:
Residues of one product (allergens, colours, flavours) may not be carried into an incompatible one, so the tank is also cleaned after each campaign of compatible batches. That is a decision of the product mix, not physics: with the minimum duration it gives = 0.942, and with the declared typical duration (1 h) the typical availability = 0.859.
6. Physics-bounded OEE
Scope of the bound. The theoretical label of means physics-bounded under the declared scenario: the ceiling follows from the physics of the operation for the declared product, equipment and schedule, and it is a bound only conditional on those declarations. It follows the common definition of all models: counts only stops required by regulation or forced by a physical mechanism, at their physical minimum duration, plus the start-up they force; is the ratio of the physics-limited ideal cycle to the cycle of the capable process; is the share of conforming units, and mass losses of conforming product are reported only as yield.
refers to the physics-limited cycle of Section 3. The result is = 0.968, set mainly by dosing accuracy; with the declared cleanings between incompatible products, oee_scenario = 0.927.
7. Assumptions and validity
See the assumption and validity lists generated from the configuration file. The correlation applies to liquids of similar density and viscosity; a heavy syrup that sinks to the bottom needs a buoyancy correction not included here, and its real blend time can be several times longer. The most influential inputs (sensitivity table) are the cleaning duration and the campaign length for OEE, the dosing accuracy and the tolerance for quality, and the pump flows for the cycle time.
References
- Grenville, R. K., Nienow, A. W. (2003). Blending of miscible liquids. In Handbook of Industrial Mixing, Wiley, 507–542. doi:10.1002/0471451452.ch9
- Nienow, A. W. (1997). On impeller circulation and mixing effectiveness in the turbulent flow regime. Chemical Engineering Science, 52, 2557–2565. doi:10.1016/S0009-2509(97)00072-9
- Jeffreys, H. (1930). The draining of a vertical plate. Mathematical Proceedings of the Cambridge Philosophical Society, 26, 204–205. doi:10.1017/s0305004100015437
- European Commission, Joint Research Centre. Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries, 2019.
- U.S. Department of Energy. Bandwidth Study on Energy Use and Potential Energy Saving Opportunities in U.S. Food and Beverage Manufacturing, 2017.
- Bell, I. H., Wronski, J., Quoilin, S., Lemort, V. (2014). Pure and pseudo-pure fluid thermophysical property evaluation and the open-source thermophysical property library CoolProp. Industrial & Engineering Chemistry Research, 53, 2498–2508. doi:10.1021/ie4033999
7Parameters and provenance
- 10 m³
Batch volume
Scenario · Fixed
Declared assumption - 1,040 kg/m³
Density of the blended product
Scenario · Uniform 1,000 to 1,060 kg/m³
Declared assumption - 0.0015 Pa·s
Dynamic viscosity of the blended product (water at 20 °C from IAPWS through CoolProp, 1.0 mPa s, up to three times that value)
Scenario · Uniform 0.001 to 0.003 Pa·s
Declared assumptionCoolProp PropsSI('V','T',293.15,'P',101325,'Water') = 1.0e-3 Pa s; the multiplier for dissolved solids is a declared assumption.
- 200 W/m³
Installed agitator power per unit volume
Scenario · Uniform 100 to 500 W/m³
Declared assumptionDesign choice; declared assumption.
- 1.3
Turbulent power number of the installed impeller (four-blade 45° pitched-blade turbine)
Scenario · Uniform 1.1 to 1.7
Declared assumptionNo open source with a quotable power number was used; declared assumption. At fixed power per volume the blend time does not depend on it; it only sets speed, Reynolds number and tip speed.
- 5.2
Constant of the turbulent blend-time correlation N theta95 = C Np^(-1/3) (T/D)^2 for H = T
Property · Fixed
Reference onlyLiterature constant (closed-access source, cited as reference only): Grenville correlation as presented by Grenville and Nienow (2003), doi:10.1002/0471451452.ch9, and Nienow (1997), doi:10.1016/S0009-2509(97)00072-9; derivation in physics_docs/mixing.en.md, section 3.
- 0.33
Impeller-to-tank diameter ratio installed
Scenario · Uniform 0.25 to 0.4
Declared assumption - 0.5
Largest impeller-to-tank diameter ratio considered for the best geometry
Scenario · Fixed
Declared assumptionDeclared design limit of the comparison; larger impellers reduce blend time and energy at equal power per volume.
- 0.167
Volume fraction of the dosed concentrate in the batch
Scenario · Uniform 0.1 to 0.25
Declared assumption - 0.01
Composition tolerance of the specification, relative to target (e.g. dissolved solids)
Scenario · Uniform 0.005 to 0.02
Declared assumption - 3
Ratio between tolerance and residual non-uniformity at which the blend is stopped
Scenario · Fixed
Declared assumptionOperating choice.
- 0.0025
Relative standard deviation of the dosed quantities (load cells or flow meters)
Scenario · Uniform 0.001 to 0.004
Declared assumption - 30 m³/h
Flow rate of the filling pumps
Scenario · Uniform 20 to 50 m³/h
Declared assumption - 30 m³/h
Flow rate of the discharge pump
Scenario · Uniform 20 to 50 m³/h
Declared assumption - 300 s
Gravity drainage time after the pump loses suction
Scenario · Uniform 120 to 600 s
Declared assumption - 30 L
Heel and line hold-up left in tank bottom, outlet, pump and pipes
Scenario · Uniform 10 to 60 L
Declared assumption - 8
Batches of compatible products between two cleanings
Scenario · Uniform 4 to 16
Declared assumption - 1 h
Duration of a typical cleaning-in-place of the tank between incompatible products
Scenario · Uniform 0.75 to 1.5 h
Declared assumptionDeclared typical programme, used for the typical availability.
- 0.374294 h
Minimum duration of the cleaning-in-place: physical minimum of the kinetic and displacement phases plus declared hold times (output cip_time_min of the cleaning model)
Property · Triangular 0.242184, 0.374294, 0.536161 h
ComputedOutput `cip_time_min` of the cleaning model: 22.46 min [14.53, 32.17].
- 24 h
Maximum interval between two cleanings of milk equipment (dairy formulations)
Regulatory · Fixed
Verified quoteShow verbatim quote
all equipment is thoroughly cleaned at least once each day usedGrade "A" Pasteurized Milk Ordinance, 2023 Revision (opens in a new tab). U.S. Department of Health and Human Services, Public Health Service, Food and Drug Administration, 2023. p. 98. PMO 2023 Revision
8Benchmarks
| Benchmark | Ceiling | Value | Provenance |
|---|---|---|---|
DOE bandwidth study: products without significant chemical reactions have a zero thermodynamic minimum energy intensityShow verbatim quoteMost food and beverage products have a zero TM energy intensity because there are no significant chemical reactions involved.Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Food and Beverage Manufacturing (opens in a new tab). U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Advanced Manufacturing Office, 2017. p. 41. DOE/EE-1571; OSTI ID 1512366 | Theoretical | 0 kJ/kg | Verified quote |
Normal product loss in milk manufacture, percent of product (whole dairy, cleaning, start-up and changeover run-off included; wider boundary than one tank)Show verbatim quoteProduct loss during milk manufacture can be as high as 3–4 %, with normally 0.5–1.5 % of the product being wasted.Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 395. EUR 29978 EN; JRC118627; doi:10.2760/243911 | Typical | 0.5 % | Verified quote |
9Unavoidable stops
- Cleaning at least once per day of use (milk equipment)Verified quote
Hygiene regulation for milk equipment; minimum duration from the cleaning model.
Show verbatim quote
all equipment is thoroughly cleaned at least once each day usedGrade "A" Pasteurized Milk Ordinance, 2023 Revision (opens in a new tab). U.S. Department of Health and Human Services, Public Health Service, Food and Drug Administration, 2023. p. 98. PMO 2023 Revision
- Cleaning between incompatible products (scenario stop: availability_scenario and typical availability only)Verified quote
Residues of one product (allergens, colours, flavours) cannot be carried into an incompatible one; the BAT reference document records the product lost because equipment is difficult to empty before cleaning or a batch change. Interval and duration are declared scenario values.
Show verbatim quote
Product loss to waste water caused by difficulties of emptying the equipment before cleaning/shift of production batch.Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 536. EUR 29978 EN; JRC118627; doi:10.2760/243911
10Assumptions
- Availability: the only physically or legally required stop is the daily cleaning of milk equipment, at the minimum duration of the cleaning model. That model is valid for recirculated pipe circuits; the spray cleaning of the tank interior is outside its validity, so the linked duration is a lower bound. Cleanings between incompatible products are a product-mix decision: they enter availability_scenario (at the minimum duration) and the typical availability (at the declared typical duration). Fill, discharge and drainage belong to the ideal batch cycle (common batch convention), so they do not reduce availability.
- Fully turbulent flow in a baffled vessel with H = T and a single impeller; the blend-time correlation applies to liquids of similar density and viscosity.
- Non-uniformity decays exponentially (first order) with a rate constant fixed by the 95 % blend time: k = ln 20 / theta95; the coefficient of variation follows the same decay from its segregated initial value.
- The blend is stopped when the residual coefficient of variation is the tolerance divided by z_h; dosing errors are independent and normally distributed; a batch outside tolerance is counted as a quality loss (it is corrected, not destroyed).
- Wall film after drainage follows Jeffreys' solution for a Newtonian liquid on a vertical plate; the bottom is assigned the same mean film thickness.
- Mixing is treated as ideal (no heat of mixing, no reaction); the thermodynamic minimum work is zero.
11Range of validity
- Low-viscosity miscible liquids (up to a few mPa s) in baffled tanks with one axial or radial impeller, impeller Reynolds number above 10 000.
- Concentrates whose density differs strongly from the diluent need a correction for buoyancy that is not included.
12Sensitivity
- Ratio between tolerance and residual non-uniformity at which the blend is stoppedelasticity +0.071Spearman ρ —
- Composition tolerance of the specification, relative to target (e.g. dissolved solids)elasticity +0.040Spearman ρ +0.66
- Relative standard deviation of the dosed quantities (load cells or flow meters)elasticity -0.039Spearman ρ -0.63
- Maximum interval between two cleanings of milk equipment (dairy formulations)elasticity +0.016Spearman ρ —
- Minimum duration of the cleaning-in-place: physical minimum of the kinetic and displacement phases plus declared hold times (output cip_time_min of the cleaning model)elasticity -0.016Spearman ρ -0.27
- Output rises with the parameter
- Output falls with the parameter
13Validation checks
- Dimensional analysis28 outputs converted to their declared unitsPassed
- Every cited value verified against its source5 verified, 0 failedPassed
- No documented value beats the theoretical limitPassed
- Ceilings in physical orderPassed
- Fractions within 0 and 1Passed
14Causes of loss in this operation
- Syrup batching changeover and setup timeSetup and adjustments1.3% [0.3–3.8%]C31 studies
- Manual cleaning of mixing equipment during changeoverSetup and adjustments1.3% [0.2–3.7%]C31 studies
- HFCS transfer pump flow below design capacityReduced speed1.2% [0.2–3.7%]D31 studies
- Tumbler shaft/body breakageEquipment failure (breakdowns)1.0% [0.2–3.1%]D31 studies
- Mixer equipment failureEquipment failure (breakdowns)1.0% [0.2–3.0%]D31 studies
- Ingredient dosing station failure or jamEquipment failure (breakdowns)1.0% [0.2–3.1%]D31 studies
- Color deviation defectProcess defects (scrap and rework)0.9% [0.2–2.8%]D31 studies
- Raw material verification and staging during changeoverSetup and adjustments0.8% [0.1–2.5%]D31 studies
- Manual raw material weighing and transfer to mixing stageSetup and adjustments0.8% [0.1–2.7%]D31 studies
- Machine start-up and shutdown procedure timeSetup and adjustments0.8% [0.1–2.7%]D31 studies
- Manual Pallet Transport Delay to Machine FloorSetup and adjustments0.8% [0.1–2.5%]D31 studies
- Bag breaker cleaning changeoverSetup and adjustments0.8% [0.1–2.6%]D31 studies
- Ingredient mixing errorProcess defects (scrap and rework)0.5% [0.1–1.8%]D31 studies
- Blender wall scrape-downIdling and minor stops (micro-stops)0.5% [0.1–1.7%]D31 studies
15References
- Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 395. EUR 29978 EN; JRC118627; doi:10.2760/243911
- Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Food and Beverage Manufacturing (opens in a new tab). U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Advanced Manufacturing Office, 2017. p. 41. DOE/EE-1571; OSTI ID 1512366
- doi:10.1002/0471451452.ch9 — Blending of miscible liquids (turbulent blend-time correlation).
- doi:10.1016/S0009-2509(97)00072-9 — Impeller circulation and mixing effectiveness in turbulent flow.
- doi:10.1017/s0305004100015437 — Drainage of a liquid film on a vertical plate.
- doi:10.1021/ie4033999 — Thermophysical property library (CoolProp).