foratvise
Get Started
Equipment failure (breakdowns)

Rotary conveyor dry-run failure

Equipment failure (breakdowns)AvailabilityConveying and accumulation

In short

It appears in fewer than 1 of every 100 lines studied.

When it appears, it takes on average about 57 % of the line's lost time. Reported by 0 of the 86 studies that could observe it (sparse evidence).

What happens

A rotary conveying element (turntable, rotary accumulator or star-wheel) continues to turn while no containers are present on it, so the drive train and bearings run unloaded for a sustained period. The lack of product load changes friction and vibration patterns, accelerating wear or overheating of the drive, gearbox or bearings until the unit trips or breaks down and requires repair.

What is done about it

Interlock the rotary drive to reduce speed or stop automatically when container presence sensors confirm the unit is running empty beyond a set interval, and route an alert to the operator before damage occurs. Complement this with preventive lubrication and vibration/current monitoring of the drive and bearings to catch early degradation from repeated empty-running cycles.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.4% [0.1–1.3%]
Expected share of lost time
0.3% [0.0–0.7%]
Share of lost time when present
57% [46–68%]
Studies / units
86 / 112
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.5% [0.0–1.9%]11 studies
  • Soft drinks, bottled water and juices
    0.5% [0.0–1.6%]28 studies
  • Brewing, wine and spirits
    0.5% [0.0–1.8%]12 studies
  • Bakery and pasta
    0.5% [0.1–2.0%]0 studies
  • Meat, poultry and seafood
    0.5% [0.1–1.9%]5 studies
  • Fruit and vegetable processing
    0.5% [0.0–2.2%]4 studies
  • Grain and oilseed milling
    0.5% [0.0–2.1%]4 studies
  • Sugar and confectionery
    0.5% [0.0–2.0%]4 studies
  • Snacks, coffee, tea and other foods
    0.5% [0.0–2.1%]4 studies
  • Animal feed and pet food
    0.6% [0.0–2.3%]5 studies
  • Food manufacturing (unspecified or mixed)
    0.5% [0.0–2.0%]9 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

A rotary conveying element (turntable, rotary accumulator or star-wheel) continues to turn while no containers are present on it, so the drive train and bearings run unloaded for a sustained period. The lack of product load changes friction and vibration patterns, accelerating wear or overheating of the drive, gearbox or bearings until the unit trips or breaks down and requires repair.

How it looks in SCADA data

Engineering guidance

MES/SCADA shows the rotary unit's run signal active with container presence sensors reporting empty for an extended span, followed by a fault alarm (overload, overcurrent or high vibration) and a change to a fault/stopped machine state. Upstream or downstream equipment may show starvation or blocking around the same timeframe, and the fault recurs intermittently before a sustained unplanned stop.

Countermeasure

Engineering guidance

Interlock the rotary drive to reduce speed or stop automatically when container presence sensors confirm the unit is running empty beyond a set interval, and route an alert to the operator before damage occurs. Complement this with preventive lubrication and vibration/current monitoring of the drive and bearings to catch early degradation from repeated empty-running cycles.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Lost time: 205 min · as reported: “rotary empty”
    Show verbatim quote
    rotary empty 14 205 295 5387 88.32 85.89
  2. Number of events: 14.0 events · as reported: “rotary empty”
    Show verbatim quote
    rotary empty 14 205 295 5387 88.32 85.89