Weighing scale failure (electrical or mechanical)
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 61 % of the line's lost time. Reported by 1 of the 120 studies that could observe it (sparse evidence).
What happens
The weighing scale used to control or verify fill weight loses accurate or stable function due to an electrical fault (load cell, wiring, power supply, controller) or a mechanical fault (worn or jammed weighing mechanism, misalignment, debris), stopping the filling operation until repaired.
What is done about it
Apply preventive maintenance and periodic calibration of load cells and mechanical weighing components, with condition monitoring of signal stability and quick-swap spare modules to restore the scale to specification rapidly.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.6% [0.1–1.5%]
- Expected share of lost time
- 0.3% [0.1–0.9%]
- Share of lost time when present
- 61% [50–72%]
- Studies / units
- 120 / 162
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.6% [0.1–2.1%]18 studies
- Soft drinks, bottled water and juices0.7% [0.1–2.0%]44 studies
- Brewing, wine and spirits0.6% [0.1–2.1%]16 studies
- Bakery and pasta0.7% [0.1–2.6%]0 studies
- Meat, poultry and seafood0.6% [0.1–2.2%]6 studies
- Fruit and vegetable processing0.6% [0.1–2.3%]4 studies
- Grain and oilseed milling0.6% [0.1–2.5%]6 studies
- Sugar and confectionery0.7% [0.1–2.5%]3 studies
- Snacks, coffee, tea and other foods0.6% [0.1–2.3%]6 studies
- Animal feed and pet food0.7% [0.1–2.4%]4 studies
- Food manufacturing (unspecified or mixed)0.6% [0.1–2.4%]13 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceThe weighing scale used to control or verify fill weight loses accurate or stable function due to an electrical fault (load cell, wiring, power supply, controller) or a mechanical fault (worn or jammed weighing mechanism, misalignment, debris), stopping the filling operation until repaired.
How it looks in SCADA data
Engineering guidanceSCADA/MES shows the filler or scale entering a fault or stopped state with an associated electrical or mechanical fault alarm code, erratic or frozen weight readings before the stop, and downstream starvation with upstream blocking while maintenance intervenes.
Countermeasure
Engineering guidanceApply preventive maintenance and periodic calibration of load cells and mechanical weighing components, with condition monitoring of signal stability and quick-swap spare modules to restore the scale to specification rapidly.
4Sources
- Share of lost time: 67.0 % · as reported: “Falha na balança”
Show verbatim quote
a equipe do projeto analisou todos estes dados e pode verificar que os problemas com a balança representavam 67 % das paradas na enchedora, e destes problemas, os elétricos representavam 98 % das paradas enquanto que os mecânicos representavam apenas 2 %.
- Share of lost time: 98.0 % · as reported: “Falha elétrica na balança”
Show verbatim quote
os problemas com a balança representavam 67 % das paradas na enchedora, e destes problemas, os elétricos representavam 98 % das paradas enquanto que os mecânicos representavam apenas 2 %.
- Share of lost time: 2.00 % · as reported: “Falha mecânica na balança”
Show verbatim quote
os problemas com a balança representavam 67 % das paradas na enchedora, e destes problemas, os elétricos representavam 98 % das paradas enquanto que os mecânicos representavam apenas 2 %.