foratvise
Get Started
Equipment failure (breakdowns)

Filling sensor failure (electrical/photoelectric)

Equipment failure (breakdowns)AvailabilityFilling

In short

It appears in fewer than 1 of every 100 lines studied.

When it appears, it takes on average about 57 % of the line's lost time. Reported by 0 of the 120 studies that could observe it (sparse evidence).

What happens

A level, position or photoelectric sensor used to control or supervise the filling process degrades, becomes misaligned, soiled or electrically faulty and stops delivering a reliable signal to the control system. The filler then cannot confirm container presence, fill level or valve position and the line is stopped until the sensor is repaired or replaced.

What is done about it

Apply a preventive maintenance schedule that includes cleaning, alignment checking and functional testing of filling sensors, and replace units showing drift or intermittent faults before they fail completely. Standardize sensor specifications and mounting brackets to simplify replacement, and add diagnostic self-test or redundancy where the sensor is critical to safety or product quality.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.4% [0.1–1.1%]
Expected share of lost time
0.2% [0.0–0.6%]
Share of lost time when present
57% [45–67%]
Studies / units
120 / 162
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.4% [0.0–1.7%]18 studies
  • Soft drinks, bottled water and juices
    0.4% [0.0–1.3%]44 studies
  • Brewing, wine and spirits
    0.4% [0.0–1.7%]16 studies
  • Bakery and pasta
    0.5% [0.0–1.9%]0 studies
  • Meat, poultry and seafood
    0.5% [0.0–1.8%]6 studies
  • Fruit and vegetable processing
    0.5% [0.0–1.8%]4 studies
  • Grain and oilseed milling
    0.5% [0.0–1.8%]6 studies
  • Sugar and confectionery
    0.5% [0.0–1.7%]3 studies
  • Snacks, coffee, tea and other foods
    0.5% [0.0–1.7%]6 studies
  • Animal feed and pet food
    0.4% [0.0–1.7%]4 studies
  • Food manufacturing (unspecified or mixed)
    0.4% [0.0–1.6%]13 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

A level, position or photoelectric sensor used to control or supervise the filling process degrades, becomes misaligned, soiled or electrically faulty and stops delivering a reliable signal to the control system. The filler then cannot confirm container presence, fill level or valve position and the line is stopped until the sensor is repaired or replaced.

How it looks in SCADA data

Engineering guidance

SCADA/MES logs show a sensor fault or out-of-range signal alarm on the filling station coinciding with a machine downstate, often with repeated intermittent fault/clear cycles before the final stop; the equivalent fault code or I/O status bit for the electrical or photoelectric input remains active for the duration of the stop. Fill count and cycle timers freeze while downstream and upstream buffers show no corresponding material flow issue.

Countermeasure

Engineering guidance

Apply a preventive maintenance schedule that includes cleaning, alignment checking and functional testing of filling sensors, and replace units showing drift or intermittent faults before they fail completely. Standardize sensor specifications and mounting brackets to simplify replacement, and add diagnostic self-test or redundancy where the sensor is critical to safety or product quality.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Lost time: 45.0 min · as reported: “Electrical sensor”
    Show verbatim quote
    Electrical sensor 2 45 107 3228 95.53 91.81
  2. Number of events: 2.00 events · as reported: “Electrical sensor”
    Show verbatim quote
    Electrical sensor 2 45 107 3228 95.53 91.81
  3. Time between events: 27.6 not reported · as reported: “Photoelectric Sensor”
    Show verbatim quote
    Waktu Kerusakan Lognormal MTTF 27,633
  4. Mean event duration: 200 not reported · as reported: “Photoelectric Sensor”
    Show verbatim quote
    Waktu Perbaikan Weibull MTTR 199,8096