foratvise
Get Started
Equipment failure (breakdowns)

Generic steam turbine performance loss (mixed causes)

Equipment failure (breakdowns)AvailabilityUtilities (steam, compressed air, chilled water, power)

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 58 % of the line's lost time. Reported by 1 of the 131 studies that could observe it (sparse evidence).

What happens

The steam turbine that drives utility generation experiences a mix of wear-related and organizational disturbances: blade or seal erosion and bearing wear reduce rotational efficiency, lubrication and governor adjustments are needed after stoppages, minor sensor or valve glitches interrupt steady operation, and start-up warm-up before the rotor reaches stable speed generates off-spec output. Because these mechanisms are not separated in the source records, the turbine is reported under several different loss headings without a single dominant physical driver.

What is done about it

Implement condition-based maintenance on blades, seals and bearings with vibration and temperature monitoring, standardize start-up warm-up ramps to shorten the unstable window, and separate the different loss contributors in the data collection system so each mechanism can be tracked and addressed independently rather than lumped under one generic turbine loss entry.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.6% [0.1–1.5%]
Expected share of lost time
0.3% [0.1–0.9%]
Share of lost time when present
58% [48–68%]
Studies / units
131 / 165
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.6% [0.1–2.2%]13 studies
  • Soft drinks, bottled water and juices
    0.6% [0.1–1.9%]26 studies
  • Brewing, wine and spirits
    0.6% [0.1–2.2%]12 studies
  • Bakery and pasta
    0.6% [0.1–1.9%]25 studies
  • Meat, poultry and seafood
    0.6% [0.1–2.4%]9 studies
  • Fruit and vegetable processing
    0.7% [0.1–2.5%]7 studies
  • Grain and oilseed milling
    0.6% [0.1–2.3%]7 studies
  • Sugar and confectionery
    0.6% [0.1–2.3%]9 studies
  • Snacks, coffee, tea and other foods
    0.6% [0.1–2.3%]5 studies
  • Animal feed and pet food
    0.6% [0.1–2.3%]7 studies
  • Food manufacturing (unspecified or mixed)
    1.0% [0.1–3.5%]11 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

The steam turbine that drives utility generation experiences a mix of wear-related and organizational disturbances: blade or seal erosion and bearing wear reduce rotational efficiency, lubrication and governor adjustments are needed after stoppages, minor sensor or valve glitches interrupt steady operation, and start-up warm-up before the rotor reaches stable speed generates off-spec output. Because these mechanisms are not separated in the source records, the turbine is reported under several different loss headings without a single dominant physical driver.

How it looks in SCADA data

Engineering guidance

SCADA/MES shows the turbine alternating between running, idle, fault and warm-up states without a consistent pattern: rotational speed trends below setpoint, intermittent short stops logged as minor stoppages, occasional fault alarms tied to maintenance work orders, and output quality flags clustered around start-up periods. No single alarm code or state duration dominates the historian trace.

Countermeasure

Engineering guidance

Implement condition-based maintenance on blades, seals and bearings with vibration and temperature monitoring, standardize start-up warm-up ramps to shorten the unstable window, and separate the different loss contributors in the data collection system so each mechanism can be tracked and addressed independently rather than lumped under one generic turbine loss entry.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Share of lost time: 85.4 % · as reported: “gangguan kecil dan waktu nganggur”
    Show verbatim quote
    Nilai gangguan kecil dan waktu nganggur 85,44 % dengan total waktu 2449,54 jam
  2. Lost time: 2,450 jam · as reported: “gangguan kecil dan waktu nganggur”
    Show verbatim quote
    Nilai gangguan kecil dan waktu nganggur 85,44 % dengan total waktu 2449,54 jam
  3. Share of lost time: 2.52 % · as reported: “Cacat produk dalam proses”
    Show verbatim quote
    hasilCacat produk dalam proses2,52 % dengan total waktu 72,12 jam
  4. Lost time: 72.1 jam · as reported: “Cacat produk dalam proses”
    Show verbatim quote
    hasilCacat produk dalam proses2,52 % dengan total waktu 72,12 jam
  5. Share of lost time: 11.6 % · as reported: “Kecepatan rendah”
    Show verbatim quote
    hasilKecepatan rendah 11,58 % dengan total waktu 331,88 jam
  6. Lost time: 332 jam · as reported: “Kecepatan rendah”
    Show verbatim quote
    hasilKecepatan rendah 11,58 % dengan total waktu 331,88 jam
  7. Share of lost time: 0.380 % · as reported: “Kerusakan peralatan”
    Show verbatim quote
    hasil Kerusakan peralatan0,38 % dengan total waktu 11 jam
  8. Lost time: 11.0 jam · as reported: “Kerusakan peralatan”
    Show verbatim quote
    hasil Kerusakan peralatan0,38 % dengan total waktu 11 jam
  9. Share of lost time: 0.0800 % · as reported: “Persiapan peralatan”
    Show verbatim quote
    hasil Persiapan peralatan 0,08 % dengan total waktu 2,41 jam
  10. Lost time: 2.41 jam · as reported: “Persiapan peralatan”
    Show verbatim quote
    hasil Persiapan peralatan 0,08 % dengan total waktu 2,41 jam
  11. Share of lost time: 0 % · as reported: “Hasil rendah”
    Show verbatim quote
    hasil Hasil rendah 0