Storage silo equipment failure (bulk raw material)
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 58 % of the line's lost time. Reported by 1 of the 127 studies that could observe it (sparse evidence).
What happens
Bulk raw material storage silos lose function when discharge gates, screw or chain conveyors, aeration fans, level probes or structural fittings break down or seize, interrupting the flow of grain or meal to downstream processing. Material bridging, rat-holing or mechanical jamming inside the silo can also stop discharge even without a component breakdown, requiring maintenance intervention to clear.
What is done about it
Apply preventive and predictive maintenance to discharge gates, conveyors, aeration systems and level instrumentation, and install bridge-breakers, vibrators or flow aids to prevent material bridging. Standardize inspection routines and spare-parts availability for critical silo components, and use redundant level sensing to detect incipient discharge problems before they escalate to a stoppage.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.6% [0.1–1.6%]
- Expected share of lost time
- 0.3% [0.1–0.9%]
- Share of lost time when present
- 58% [46–68%]
- Studies / units
- 127 / 161
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.7% [0.1–2.5%]13 studies
- Soft drinks, bottled water and juices0.6% [0.1–2.1%]26 studies
- Brewing, wine and spirits0.6% [0.1–2.3%]11 studies
- Bakery and pasta0.6% [0.1–2.2%]24 studies
- Meat, poultry and seafood0.7% [0.1–2.4%]9 studies
- Fruit and vegetable processing0.7% [0.1–2.5%]7 studies
- Grain and oilseed milling0.7% [0.1–2.3%]6 studies
- Sugar and confectionery0.7% [0.1–2.5%]9 studies
- Snacks, coffee, tea and other foods0.6% [0.1–2.3%]5 studies
- Animal feed and pet food1.0% [0.1–3.6%]7 studies
- Food manufacturing (unspecified or mixed)0.7% [0.1–2.5%]10 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceBulk raw material storage silos lose function when discharge gates, screw or chain conveyors, aeration fans, level probes or structural fittings break down or seize, interrupting the flow of grain or meal to downstream processing. Material bridging, rat-holing or mechanical jamming inside the silo can also stop discharge even without a component breakdown, requiring maintenance intervention to clear.
How it looks in SCADA data
Engineering guidanceSCADA/MES shows the storage sector or silo discharge equipment in a fault or stopped state, with level sensors reporting flat or erratic readings and discharge motor or conveyor amperage dropping to zero despite a demand signal. Downstream receiving equipment registers starvation (infeed empty, waiting for material) while the maintenance log records a corrective work order against the silo asset.
Countermeasure
Engineering guidanceApply preventive and predictive maintenance to discharge gates, conveyors, aeration systems and level instrumentation, and install bridge-breakers, vibrators or flow aids to prevent material bridging. Standardize inspection routines and spare-parts availability for critical silo components, and use redundant level sensing to detect incipient discharge problems before they escalate to a stoppage.
4Sources
- IMPACT OF FACILITY MAINTENANCE SYSTEM ON PRODUCT PHYSICAL LOSSES IN A POULTRY FEED MILL UNIT (2011)Open sourceLost time: 6.77 Kg.h-1 · as reported: “Storage sector (corn grains)”
Show verbatim quote
Storage 1058 0.006 ± 0.002 6.771 ± 2.116 Kg 15.11
- IMPACT OF FACILITY MAINTENANCE SYSTEM ON PRODUCT PHYSICAL LOSSES IN A POULTRY FEED MILL UNIT (2011)Open sourceLost time: 12.9 Kg.h-1 · as reported: “Storage sector (soybean meal)”
Show verbatim quote
Storage 695 0.036 ± 0.005 12.916 ± 1.790 Kg 78.11