Tray-forming clamp/finger mechanism fault
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 57 % of the line's lost time. Reported by 2 of the 112 studies that could observe it (limited evidence).
What happens
The tray former uses a set of mechanical fingers or clamps to hold, fold and release the tray blank while it is shaped; wear, misalignment or jamming of these clamping parts prevents correct closing or opening of the finger assembly. When the clamps cannot release or re-engage properly the forming cycle stalls or produces a malformed tray, and the mechanism must be freed and reset before production can resume.
What is done about it
Inspect and replace worn clamp fingers, bushings or springs, verify alignment and free travel of the clamping assembly, and lubricate pivot points according to the maintenance plan. Review and adjust the clamp open/close timing and sensor calibration, and include the finger mechanism in preventive maintenance to detect wear before it causes stoppages.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.7% [0.2–1.9%]
- Expected share of lost time
- 0.4% [0.1–1.1%]
- Share of lost time when present
- 57% [47–67%]
- Studies / units
- 112 / 155
- Evidence grade
- C
Grade C: 2 to 4 studies, or an interval wider than 0.35.
2Probability by segment
- Dairy products0.8% [0.1–2.8%]14 studies
- Soft drinks, bottled water and juices1.3% [0.2–3.7%]33 studies
- Brewing, wine and spirits0.8% [0.1–2.6%]14 studies
- Bakery and pasta0.9% [0.1–3.0%]6 studies
- Meat, poultry and seafood0.9% [0.1–3.1%]6 studies
- Fruit and vegetable processing0.9% [0.1–3.3%]4 studies
- Grain and oilseed milling0.9% [0.1–3.0%]4 studies
- Sugar and confectionery0.9% [0.1–3.3%]4 studies
- Snacks, coffee, tea and other foods0.8% [0.1–3.0%]8 studies
- Animal feed and pet food0.9% [0.1–2.9%]5 studies
- Food manufacturing (unspecified or mixed)0.8% [0.1–2.7%]14 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceThe tray former uses a set of mechanical fingers or clamps to hold, fold and release the tray blank while it is shaped; wear, misalignment or jamming of these clamping parts prevents correct closing or opening of the finger assembly. When the clamps cannot release or re-engage properly the forming cycle stalls or produces a malformed tray, and the mechanism must be freed and reset before production can resume.
How it looks in SCADA data
Engineering guidanceMES/SCADA logs show the tray-forming station in fault or stopped state with clamp or finger position sensors outside their expected end-of-travel values, often paired with a cycle-fault or jam alarm specific to the forming axis. Repeated short stop codes on the same station, sometimes followed by a longer maintenance-type stop, indicate recurring clamp engagement or release problems.
Countermeasure
Engineering guidanceInspect and replace worn clamp fingers, bushings or springs, verify alignment and free travel of the clamping assembly, and lubricate pivot points according to the maintenance plan. Review and adjust the clamp open/close timing and sensor calibration, and include the finger mechanism in preventive maintenance to detect wear before it causes stoppages.
4Sources
- การปรับปรุงแผนการบำรุงรักษาเชิงป้องกันเครื่องจักรของสายการผลิตเครื่องดื่มบรรจุภัณฑ์ชนิดกระป๋อง (2026)Open sourceNumber of events: 82.0 events · as reported: “Tray forming system”
Show verbatim quote
จากการวิเคราะห์ข้อมูลในตารางที่ 3 พบว่าปัญหาหลักมาจากกลุ่มระบบจัดการขึ้นรูปถาด ซึ่งมีความถี่ความขัดข้องสูงถึง 82 ครั้ง คิดเป็นร้อยละ 65.60 ของปัญหาทั้งหมด
- การปรับปรุงแผนการบำรุงรักษาเชิงป้องกันเครื่องจักรของสายการผลิตเครื่องดื่มบรรจุภัณฑ์ชนิดกระป๋อง (2026)Open sourceShare of loss events: 65.6 % · as reported: “Tray forming system”
Show verbatim quote
จากการวิเคราะห์ข้อมูลในตารางที่ 3 พบว่าปัญหาหลักมาจากกลุ่มระบบจัดการขึ้นรูปถาด ซึ่งมีความถี่ความขัดข้องสูงถึง 82 ครั้ง คิดเป็นร้อยละ 65.60 ของปัญหาทั้งหมด
- การเพิ่มประสิทธิภาพกระบวนการบรรจุหีบห่อขวดน้ำอัดลม: การลดเวลาการ เปลี่ยนอะไหล่และการปรับตั้งค่าเครื่องจักรในสายการผลิต PET5 (2025)Open sourceLost time: 10.0 min · as reported: “Releasing the finger parts clamping system”
Show verbatim quote
ปลดล็อคระบบจับยึด (Finger Parts) ในเครื่องพารามิเตอร์ 1 10