Underfill / short fill volume
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 47 % of the line's lost time. Reported by 2 of the 76 studies that could observe it (sparse evidence).
What happens
During blow-moulding/forming and filling of containers, the dosed or blown volume falls below the target specification because of worn dosing components, incorrect valve timing, pressure or temperature drift in the forming station, or variability in preform/parison wall thickness that changes the final container capacity. The result is finished units whose liquid or product content is below the declared or required volume, detected as a first-pass quality defect rather than a machine stoppage.
What is done about it
Calibrate and verify dosing valves, nozzles or volumetric cylinders against a reference standard, adjust forming pressure/temperature profiles to the preform specification, and tighten statistical process control limits on fill volume with automatic line stop or rework diversion when drift is detected. Preventive replacement of worn sealing and metering parts reduces recurrence.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.7% [0.1–2.1%]
- Expected share of lost time
- 0.3% [0.1–1.0%]
- Share of lost time when present
- 47% [35–59%]
- Studies / units
- 76 / 96
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.8% [0.1–3.0%]5 studies
- Soft drinks, bottled water and juices1.1% [0.1–4.2%]11 studies
- Brewing, wine and spirits0.9% [0.1–3.4%]0 studies
- Bakery and pasta0.7% [0.1–2.5%]25 studies
- Meat, poultry and seafood0.9% [0.1–3.2%]3 studies
- Fruit and vegetable processing0.8% [0.1–3.2%]3 studies
- Grain and oilseed milling0.9% [0.1–3.2%]0 studies
- Sugar and confectionery0.8% [0.1–2.9%]8 studies
- Snacks, coffee, tea and other foods0.8% [0.1–3.0%]7 studies
- Animal feed and pet food0.8% [0.1–3.1%]6 studies
- Food manufacturing (unspecified or mixed)0.8% [0.1–3.1%]8 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceDuring blow-moulding/forming and filling of containers, the dosed or blown volume falls below the target specification because of worn dosing components, incorrect valve timing, pressure or temperature drift in the forming station, or variability in preform/parison wall thickness that changes the final container capacity. The result is finished units whose liquid or product content is below the declared or required volume, detected as a first-pass quality defect rather than a machine stoppage.
How it looks in SCADA data
Engineering guidanceMES/SCADA shows normal machine running states (no downtime event) combined with checkweigher or volume-sensor readings trending below the lower control limit, rising reject or downgrade counters on the inspection station, and recurring low-fill alarms without an associated stop code. Statistical process data (fill-volume trend charts) typically show a gradual drift rather than a step change.
Countermeasure
Engineering guidanceCalibrate and verify dosing valves, nozzles or volumetric cylinders against a reference standard, adjust forming pressure/temperature profiles to the preform specification, and tighten statistical process control limits on fill volume with automatic line stop or rework diversion when drift is detected. Preventive replacement of worn sealing and metering parts reduces recurrence.
4Sources
- Defect rate: 7.00 % · as reported: “Volume Kurang”
Show verbatim quote
Volume Kurang 24007 7% 96%
- Number of events: 24,007 units · as reported: “Volume Kurang”
Show verbatim quote
Volume Kurang | 24007 | 7% | 96%
- Share of loss events: 7.00 % · as reported: “Volume Kurang”
Show verbatim quote
Volume Kurang | 24007 | 7% | 96%