In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 55 % of the line's lost time. Reported by 1 of the 76 studies that could observe it (sparse evidence).
What happens
A dosing, pneumatic or hydraulic valve on the forming equipment degrades, sticks or loses sealing integrity, so its position or flow output no longer matches the commanded setpoint. Restoring correct product flow or mould filling requires the valve to be adjusted, recalibrated or replaced before stable production can resume.
What is done about it
Apply preventive maintenance with scheduled inspection and replacement of valve seals, seats and actuators, and verify valve calibration and response as part of the changeover checklist. Where feasible, use quick-change or redundant valve modules so a failing valve can be swapped without extending setup time.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.6% [0.1–1.8%]
- Expected share of lost time
- 0.3% [0.1–1.0%]
- Share of lost time when present
- 55% [42–66%]
- Studies / units
- 76 / 96
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.7% [0.1–2.7%]5 studies
- Soft drinks, bottled water and juices0.7% [0.1–2.6%]11 studies
- Brewing, wine and spirits0.8% [0.1–3.1%]0 studies
- Bakery and pasta0.6% [0.1–2.2%]25 studies
- Meat, poultry and seafood0.8% [0.1–3.0%]3 studies
- Fruit and vegetable processing0.7% [0.1–2.8%]3 studies
- Grain and oilseed milling0.8% [0.1–3.0%]0 studies
- Sugar and confectionery1.0% [0.1–3.6%]8 studies
- Snacks, coffee, tea and other foods0.7% [0.1–2.7%]7 studies
- Animal feed and pet food0.7% [0.1–2.7%]6 studies
- Food manufacturing (unspecified or mixed)0.7% [0.1–2.7%]8 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceA dosing, pneumatic or hydraulic valve on the forming equipment degrades, sticks or loses sealing integrity, so its position or flow output no longer matches the commanded setpoint. Restoring correct product flow or mould filling requires the valve to be adjusted, recalibrated or replaced before stable production can resume.
How it looks in SCADA data
Engineering guidanceSCADA shows a deviation alarm between commanded and actual valve position or flow feedback, repeated actuation cycles without reaching the target state, and an extended machine state logged as adjustment or changeover rather than a short fault. Downstream forming cycle counts stall or show irregular timing while the valve fault is active.
Countermeasure
Engineering guidanceApply preventive maintenance with scheduled inspection and replacement of valve seals, seats and actuators, and verify valve calibration and response as part of the changeover checklist. Where feasible, use quick-change or redundant valve modules so a failing valve can be swapped without extending setup time.
4Sources
- CHANGEOVER TIME REDUCTION THROUGH LEAN TOOL “SMED” – A CASE STUDY FROM FOOD SECTOR (2018)Open sourceShare of lost time: 6.00 % · as reported: “breakdown (within changeover)”
Show verbatim quote
internal; 83% external; 17% breakdown; 6% Figure 9 Internal vs external activities. Source: own
- CHANGEOVER TIME REDUCTION THROUGH LEAN TOOL “SMED” – A CASE STUDY FROM FOOD SECTOR (2018)Open sourceMean event duration: 13.0 min · as reported: “Valve failure”
Show verbatim quote
Valve failure: 0:13:00