foratvise
Get Started
Setup and adjustments

Valve Failure

Setup and adjustmentsAvailabilityForming, moulding and depositing

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 55 % of the line's lost time. Reported by 1 of the 76 studies that could observe it (sparse evidence).

What happens

A dosing, pneumatic or hydraulic valve on the forming equipment degrades, sticks or loses sealing integrity, so its position or flow output no longer matches the commanded setpoint. Restoring correct product flow or mould filling requires the valve to be adjusted, recalibrated or replaced before stable production can resume.

What is done about it

Apply preventive maintenance with scheduled inspection and replacement of valve seals, seats and actuators, and verify valve calibration and response as part of the changeover checklist. Where feasible, use quick-change or redundant valve modules so a failing valve can be swapped without extending setup time.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.6% [0.1–1.8%]
Expected share of lost time
0.3% [0.1–1.0%]
Share of lost time when present
55% [42–66%]
Studies / units
76 / 96
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.7% [0.1–2.7%]5 studies
  • Soft drinks, bottled water and juices
    0.7% [0.1–2.6%]11 studies
  • Brewing, wine and spirits
    0.8% [0.1–3.1%]0 studies
  • Bakery and pasta
    0.6% [0.1–2.2%]25 studies
  • Meat, poultry and seafood
    0.8% [0.1–3.0%]3 studies
  • Fruit and vegetable processing
    0.7% [0.1–2.8%]3 studies
  • Grain and oilseed milling
    0.8% [0.1–3.0%]0 studies
  • Sugar and confectionery
    1.0% [0.1–3.6%]8 studies
  • Snacks, coffee, tea and other foods
    0.7% [0.1–2.7%]7 studies
  • Animal feed and pet food
    0.7% [0.1–2.7%]6 studies
  • Food manufacturing (unspecified or mixed)
    0.7% [0.1–2.7%]8 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

A dosing, pneumatic or hydraulic valve on the forming equipment degrades, sticks or loses sealing integrity, so its position or flow output no longer matches the commanded setpoint. Restoring correct product flow or mould filling requires the valve to be adjusted, recalibrated or replaced before stable production can resume.

How it looks in SCADA data

Engineering guidance

SCADA shows a deviation alarm between commanded and actual valve position or flow feedback, repeated actuation cycles without reaching the target state, and an extended machine state logged as adjustment or changeover rather than a short fault. Downstream forming cycle counts stall or show irregular timing while the valve fault is active.

Countermeasure

Engineering guidance

Apply preventive maintenance with scheduled inspection and replacement of valve seals, seats and actuators, and verify valve calibration and response as part of the changeover checklist. Where feasible, use quick-change or redundant valve modules so a failing valve can be swapped without extending setup time.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Share of lost time: 6.00 % · as reported: “breakdown (within changeover)”
    Show verbatim quote
    internal; 83% external; 17% breakdown; 6% Figure 9 Internal vs external activities. Source: own
  2. Mean event duration: 13.0 min · as reported: “Valve failure”
    Show verbatim quote
    Valve failure: 0:13:00