foratvise
Get Started
Equipment failure (breakdowns)

Nylon washer/seal wear and failure

Equipment failure (breakdowns)AvailabilityFilling

In short

It appears in fewer than 1 of every 100 lines studied.

When it appears, it takes on average about 58 % of the line's lost time. Reported by 0 of the 120 studies that could observe it (sparse evidence).

What happens

A small nylon washer or sealing ring used in the filling valve, nozzle or dosing mechanism gradually wears, deforms or cracks under repeated mechanical cycling and contact with product or cleaning agents. Once the washer loses its sealing or cushioning function, the valve or filling head no longer closes, aligns or doses correctly, producing leaks, misalignment or jamming that stops the equipment until the part is replaced.

What is done about it

Establish a preventive replacement schedule for nylon washers and seals based on cycle count or condition inspection rather than waiting for failure, and keep spares readily available at the line. Evaluate upgrading to a more wear-resistant or chemically compatible elastomer or composite material to extend service life.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.4% [0.1–1.1%]
Expected share of lost time
0.2% [0.0–0.7%]
Share of lost time when present
58% [46–68%]
Studies / units
120 / 162
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.4% [0.0–1.7%]18 studies
  • Soft drinks, bottled water and juices
    0.4% [0.0–1.3%]44 studies
  • Brewing, wine and spirits
    0.4% [0.0–1.6%]16 studies
  • Bakery and pasta
    0.5% [0.0–1.9%]0 studies
  • Meat, poultry and seafood
    0.5% [0.0–1.8%]6 studies
  • Fruit and vegetable processing
    0.5% [0.0–1.8%]4 studies
  • Grain and oilseed milling
    0.5% [0.0–1.9%]6 studies
  • Sugar and confectionery
    0.5% [0.0–1.8%]3 studies
  • Snacks, coffee, tea and other foods
    0.5% [0.0–1.8%]6 studies
  • Animal feed and pet food
    0.5% [0.0–1.9%]4 studies
  • Food manufacturing (unspecified or mixed)
    0.4% [0.0–1.7%]13 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

A small nylon washer or sealing ring used in the filling valve, nozzle or dosing mechanism gradually wears, deforms or cracks under repeated mechanical cycling and contact with product or cleaning agents. Once the washer loses its sealing or cushioning function, the valve or filling head no longer closes, aligns or doses correctly, producing leaks, misalignment or jamming that stops the equipment until the part is replaced.

How it looks in SCADA data

Engineering guidance

Appears as unplanned stop events on the filler logged against a specific filling head or valve, often preceded by intermittent dosing or leak alarms before the full stop. Maintenance/work-order records reference washer or seal replacement, and the stop duration is consistent with a manual mechanical repair rather than a jam clearance.

Countermeasure

Engineering guidance

Establish a preventive replacement schedule for nylon washers and seals based on cycle count or condition inspection rather than waiting for failure, and keep spares readily available at the line. Evaluate upgrading to a more wear-resistant or chemically compatible elastomer or composite material to extend service life.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Time between events: 23,756 not reported · as reported: “Nilon Y Wasner”
    Show verbatim quote
    Waktu Kerusakan Weibull MTTF 23756
  2. Mean event duration: 107 not reported · as reported: “Nilon Y Wasner”
    Show verbatim quote
    Waktu Perbaikan Weibull MTTR 107