1Bibliographic record
- Authors
- Teresa Margarida Pinto Ribeiro Morgado, Jorge Miguel Chaves Sandiães, Helena V. G. Navas
- Year
- 2019
- Venue
- Quality Innovation Prosperity
- Country
- Portugal
- Segment
- Brewing, wine and spirits
- Process family
- Filling and packaging line
- Study type
- Before/after intervention
- Extraction scope
- Full text
- Size
- 1 plants · 1 lines · 9 machines
- Observation period
- —
- Data collection
- not_reported
- Intervention
Show the setting as described by the study
The development of this work was performed in a can filling line of 33 cl and 37.5 cl, having the filling capacity of 60,000 cans per hour.
2Risk of bias
Scored with the rubric of the protocol: 2 low concern, 1 some concerns, 0 high concern.
Total score 8Moderate risk
| Item | Score |
|---|---|
| Is the observed line, machine or plant described well enough to classify its segment, process and equipment?Product, process and equipment are all described. | 2 / 2 |
| Is the observation period long enough and reported?Period not reported. | 0 / 2 |
| How were loss data collected?Interviews, estimates, or method not reported. | 0 / 2 |
| Are OEE, loading time and the loss categories defined explicitly?No definition; metrics are reported as bare numbers. | 0 / 2 |
| Does the loss breakdown account for the total loss it claims to explain?Only the top causes are reported and the unexplained remainder can be computed. | 1 / 2 |
| Is there evidence of selective reporting of favourable results?Observational study, or intervention study that reports baseline and post-intervention data with the same method. | 2 / 2 |
| Are the reported numbers internally consistent?Small inconsistencies (2 to 10 percentage points) or values that cannot be cross-checked. | 1 / 2 |
| Could conflicts of interest or the source of the data bias the result?Academic or independent study, or conflicts declared and unrelated to the result. | 2 / 2 |
3Extracted data
Each datum with its classification and the verbatim quote that states it.
| Reported cause | Loss category | Metric | Value | Extraction |
|---|---|---|---|---|
Product Exchange (Refrigerant)Show verbatim quote (Table 5)Product Exchange (Refrigerant) 66.1 27.0 59.1 | Setup and adjustments | Mean event duration | 66.1 min | Single extractor |
Product Exchange (Beer)Show verbatim quote (Table 5)Product Exchange (Beer) 19.7 6.0 69.5 | Setup and adjustments | Mean event duration | 19.7 min | Single extractor |
Format Exchange (Hs Mp For P12p)Show verbatim quote (Table 5)Format Exchange (Hs Mp For P12p) 89.3 35.9 59.8 | Setup and adjustments | Mean event duration | 89.3 min | Single extractor |
Product Exchange (Refrigerant)Show verbatim quote (Table 5)Product Exchange (Refrigerant) 66.1 27.0 59.1 | Setup and adjustments | Mean event duration | 27.0 min | Single extractor |
Product Exchange (Beer)Show verbatim quote (Table 5)Product Exchange (Beer) 19.7 6.0 69.5 | Setup and adjustments | Mean event duration | 6.00 min | Single extractor |
Format Exchange (Hs Mp For P12p)Show verbatim quote (Table 5)Format Exchange (Hs Mp For P12p) 89.3 35.9 59.8 | Setup and adjustments | Mean event duration | 35.9 min | Single extractor |
Observation units
- Line 94 filling line · Whole line or unspecified equipment · Baseline
- Line 94 filling line · Whole line or unspecified equipment · After intervention