Included study
Penerapan Metode Total Productive Maintenance Dan Overall Equipment Effectiveness Pada Mesin Sterilizer Di PT. Tri Cahaya Sawit
1Bibliographic record
- Authors
- Roy Aldo Sihombing, Zefanya Situmorang, Jusra Tampubolon Tampubolon
- Year
- 2025
- Venue
- SPROCKET JOURNAL OF MECHANICAL ENGINEERING
- Country
- Indonesia
- Segment
- Grain and oilseed milling
- Process family
- Thermal processing
- Study type
- Before/after intervention
- Extraction scope
- Full text
- Size
- 1 plants · 1 lines · 1 machines
- Observation period
- 122 days
- Data collection
- manual_logs
- Intervention
Show the setting as described by the study
Salah satu mesin vital dalam proses tersebut adalah mesin sterilizer yang berfungsi untuk menghentikan aktivitas enzim, melunakkan buah, dan mempermudah perontokan tandan.
2Risk of bias
Scored with the rubric of the protocol: 2 low concern, 1 some concerns, 0 high concern.
Total score 11Moderate risk
| Item | Score |
|---|---|
| Is the observed line, machine or plant described well enough to classify its segment, process and equipment?Product, process and equipment are all described. | 2 / 2 |
| Is the observation period long enough and reported?Period reported but shorter than 30 days, or only the number of shifts is given. | 1 / 2 |
| How were loss data collected?Manual logs or maintenance records with unknown completeness. | 1 / 2 |
| Are OEE, loading time and the loss categories defined explicitly?A standard definition is cited but its application is not shown. | 1 / 2 |
| Does the loss breakdown account for the total loss it claims to explain?Only selected causes are reported and the total is unknown. | 0 / 2 |
| Is there evidence of selective reporting of favourable results?Observational study, or intervention study that reports baseline and post-intervention data with the same method. | 2 / 2 |
| Are the reported numbers internally consistent?Recomputed totals, shares and OEE factors agree with the reported values within 2 percentage points. | 2 / 2 |
| Could conflicts of interest or the source of the data bias the result?Academic or independent study, or conflicts declared and unrelated to the result. | 2 / 2 |
3Extracted data
Each datum with its classification and the verbatim quote that states it.
| Reported cause | Loss category | Metric | Value | Extraction |
|---|---|---|---|---|
—sterilizerShow verbatim quote (Section 3.2 Pembahasan)Availability Rate meningkat dari 92,67% menjadi 93,25%. | none | Availability | 93.3 % | Both extractors agreed |
—sterilizerShow verbatim quote (Section 3.2 Pembahasan)Performance Rate yang sebelumnya tidak memenuhi standar (91,87%) berhasil meningkat menjadi 95,42%. | none | Performance | 95.4 % | Both extractors agreed |
—sterilizerShow verbatim quote (Section 3.2 Pembahasan)Quality Rate juga menunjukkan peningkatan signifikan, dari 97,43% menjadi 99,12%, melebihi standar mutu industri. | none | Quality | 99.1 % | Both extractors agreed |
—sterilizerShow verbatim quote (Abstract)Hasil pengukuran menunjukkan nilai rata-rata OEE sebesar 82,5%, dengan availability rate 92,67%, performance rate 91,87%, dan quality rate 97,43%. | none | Availability | 92.7 % | Both extractors agreed |
—sterilizerShow verbatim quote (Abstract)Hasil pengukuran menunjukkan nilai rata-rata OEE sebesar 82,5%, dengan availability rate 92,67%, performance rate 91,87%, dan quality rate 97,43%. | none | Performance | 91.9 % | Both extractors agreed |
—sterilizerShow verbatim quote (Abstract)Hasil pengukuran menunjukkan nilai rata-rata OEE sebesar 82,5%, dengan availability rate 92,67%, performance rate 91,87%, dan quality rate 97,43%. | none | Quality | 97.4 % | Both extractors agreed |
—sterilizerShow verbatim quote (Section 3.2 Pembahasan)Nilai OEE Total meningkat dari 83,21% menjadi 88,13%, yang berarti mesin sterilizer telah mencapai dan melampaui standar internasional minimum (≥ 85%) untuk efektivitas peralatan. | none | OEE | 88.1 % | Both extractors agreed |
—sterilizerShow verbatim quote (Section 3.2 Pembahasan)Nilai OEE Total meningkat dari 83,21% menjadi 88,13%, yang berarti mesin sterilizer telah mencapai dan melampaui standar internasional minimum (≥ 85%) untuk efektivitas peralatan. | none | OEE | 83.2 % | Both extractors agreed |
—sterilizerShow verbatim quote (Abstract)Hasil pengukuran menunjukkan nilai rata-rata OEE sebesar 82,5%, dengan availability rate 92,67%, performance rate 91,87%, dan quality rate 97,43%. | none | OEE | 82.5 % | Single extractor |
downtimesterilizerShow verbatim quote (Section 1 Pendahuluan)tercatat bahwa mesin sterilizer mengalami downtime rata-rata 47 jam per bulan, dengan jumlah gangguan teknis mencapai 6–8 kali per bulan. | Equipment failure (breakdowns) | Lost time | 47.0 h/month | Single extractor |
Observation units
- Sterilizer · Sterilization (retort, UHT) · After intervention
- Sterilizer · Sterilization (retort, UHT) · Baseline