1Bibliographic record
- Authors
- David, G.A., Paulo Monteiro de Carvalho Monson, P. Aguiar, Conceição Junior, P. O., Eduardo P. Godoy, Victória Dutra Kennerly
- Year
- 2024
- Venue
- Congresso Brasileiro de Automática
- Country
- Brazil
- Segment
- Animal feed and pet food
- Process family
- Whole plant or unspecified
- Study type
- Before/after intervention
- Extraction scope
- Full text
- Size
- 1 plants · 1 lines · 2 machines
- Observation period
- 151 days
- Data collection
- automatic_monitoring
- Intervention
Show the setting as described by the study
O monitoramento foi realizado em um ponto crítico de um sistema produtivo responsável pelo transporte de ração animal, cuja indisponibilidade impacta toda a produção anterior.
2Risk of bias
Scored with the rubric of the protocol: 2 low concern, 1 some concerns, 0 high concern.
Total score 14Low risk
| Item | Score |
|---|---|
| Is the observed line, machine or plant described well enough to classify its segment, process and equipment?Product, process and equipment are all described. | 2 / 2 |
| Is the observation period long enough and reported?Period reported and at least 30 days of production (or at least 100 recorded events). | 2 / 2 |
| How were loss data collected?Automatic line monitoring, or systematic logs covering every stop in the period. | 2 / 2 |
| Are OEE, loading time and the loss categories defined explicitly?A standard definition is cited but its application is not shown. | 1 / 2 |
| Does the loss breakdown account for the total loss it claims to explain?The reported causes or categories sum to at least 90% of the stated total, or an explicit "other" class closes the balance. | 2 / 2 |
| Is there evidence of selective reporting of favourable results?Observational study, or intervention study that reports baseline and post-intervention data with the same method. | 2 / 2 |
| Are the reported numbers internally consistent?Small inconsistencies (2 to 10 percentage points) or values that cannot be cross-checked. | 1 / 2 |
| Could conflicts of interest or the source of the data bias the result?Academic or independent study, or conflicts declared and unrelated to the result. | 2 / 2 |
3Extracted data
Each datum with its classification and the verbatim quote that states it.
| Reported cause | Loss category | Metric | Value | Extraction |
|---|---|---|---|---|
Parada Geral (PG)Show verbatim quote (Table 2)Tempo Total de PG(H) 87 178 126 | Not classifiable from the report | Lost time | 87.0 h | Single extractor |
Parada Geral (PG)Show verbatim quote (Table 2)Tempo Total de PG(H) 87 178 126 | Not classifiable from the report | Lost time | 178 h | Single extractor |
Parada Geral (PG)Show verbatim quote (Table 2)Tempo Total de PG(H) 87 178 126 | Not classifiable from the report | Lost time | 126 h | Single extractor |
Parada Geral (PG)Show verbatim quote (Table 2)Nº ocorrências PG 634 589 485 | Not classifiable from the report | Number of events | 634 events | Single extractor |
Parada Geral (PG)Show verbatim quote (Table 2)Nº ocorrências PG 634 589 485 | Not classifiable from the report | Number of events | 589 events | Single extractor |
Parada Geral (PG)Show verbatim quote (Table 2)Nº ocorrências PG 634 589 485 | Not classifiable from the report | Number of events | 485 events | Single extractor |
Paradas por Falha (PF)Show verbatim quote (Table 2)Tempo Total de PF(H) 38 41 46 | Idling and minor stops (micro-stops) | Lost time | 38.0 h | Single extractor |
Paradas por Falha (PF)Show verbatim quote (Table 2)Tempo Total de PF(H) 38 41 46 | Idling and minor stops (micro-stops) | Lost time | 41.0 h | Single extractor |
Paradas por Falha (PF)Show verbatim quote (Table 2)Tempo Total de PF(H) 38 41 46 | Idling and minor stops (micro-stops) | Lost time | 46.0 h | Single extractor |
Paradas por Falha (PF)Show verbatim quote (Table 2)Nº ocorrências PF 277 265 293 | Idling and minor stops (micro-stops) | Number of events | 277 events | Single extractor |
Paradas por Falha (PF)Show verbatim quote (Table 2)Nº ocorrências PF 277 265 293 | Idling and minor stops (micro-stops) | Number of events | 265 events | Single extractor |
Paradas por Falha (PF)Show verbatim quote (Table 2)Nº ocorrências PF 277 265 293 | Idling and minor stops (micro-stops) | Number of events | 293 events | Single extractor |
Paradas para Reparo (PR)Show verbatim quote (Table 2)Tempo Total de PR(H) 28 121 71 | Equipment failure (breakdowns) | Lost time | 28.0 h | Single extractor |
Paradas para Reparo (PR)Show verbatim quote (Table 2)Tempo Total de PR(H) 28 121 71 | Equipment failure (breakdowns) | Lost time | 121 h | Single extractor |
Paradas para Reparo (PR)Show verbatim quote (Table 2)Tempo Total de PR(H) 28 121 71 | Equipment failure (breakdowns) | Lost time | 71.0 h | Single extractor |
Paradas para Reparo (PR)Show verbatim quote (Table 2)Nº ocorrências PR 26 77 53 | Equipment failure (breakdowns) | Number of events | 26.0 events | Single extractor |
Paradas para Reparo (PR)Show verbatim quote (Table 2)Nº ocorrências PR 26 77 53 | Equipment failure (breakdowns) | Number of events | 77.0 events | Single extractor |
Paradas para Reparo (PR)Show verbatim quote (Table 2)Nº ocorrências PR 26 77 53 | Equipment failure (breakdowns) | Number of events | 53.0 events | Single extractor |
—Show verbatim quote (Table 2)MTBF 1,44 1,74 1,64 | Equipment failure (breakdowns) | Time between events | 1.44 h | Single extractor |
—Show verbatim quote (Table 2)MTBF 1,44 1,74 1,64 | Equipment failure (breakdowns) | Time between events | 1.74 h | Single extractor |
—Show verbatim quote (Table 2)MTBF 1,44 1,74 1,64 | Equipment failure (breakdowns) | Time between events | 1.64 h | Single extractor |
—Show verbatim quote (Table 2)MTTR 1,11 1,00 1,04 | Equipment failure (breakdowns) | Mean event duration | 1.11 h | Single extractor |
—Show verbatim quote (Table 2)MTTR 1,11 1,00 1,04 | Equipment failure (breakdowns) | Mean event duration | 1.00 h | Single extractor |
—Show verbatim quote (Table 2)MTTR 1,11 1,00 1,04 | Equipment failure (breakdowns) | Mean event duration | 1.04 h | Single extractor |
—Show verbatim quote (Table 2)Disponibilidade(%) 56,5 65,1 61,3 | none | Availability | 56.5 % | Single extractor |
—Show verbatim quote (Table 2)Disponibilidade(%) 56,5 65,1 61,3 | none | Availability | 65.1 % | Single extractor |
—Show verbatim quote (Table 2)Disponibilidade(%) 56,5 65,1 61,3 | none | Availability | 61.3 % | Single extractor |
—Show verbatim quote (Table 2)Rendimento(%) 83 76 81 | none | Performance | 83.0 % | Single extractor |
—Show verbatim quote (Table 2)Rendimento(%) 83 76 81 | none | Performance | 76.0 % | Single extractor |
—Show verbatim quote (Table 2)Rendimento(%) 83 76 81 | none | Performance | 81.0 % | Single extractor |
Parada Geral (PG)Show verbatim quote (Table 3)Tempo Total de PG(H) 87 178 126 135 123 30 651 | Not classifiable from the report | Lost time | 135 h | Single extractor |
Parada Geral (PG)Show verbatim quote (Table 3)Tempo Total de PG(H) 87 178 126 135 123 30 651 | Not classifiable from the report | Lost time | 123 h | Single extractor |
Parada Geral (PG)Show verbatim quote (Table 3)Tempo Total de PG(H) 87 178 126 135 123 30 651 | Not classifiable from the report | Lost time | 30.0 h | Single extractor |
Parada Geral (PG)Show verbatim quote (Table 3)Nº ocorrências PG 634 589 485 578 650 126 3062 | Not classifiable from the report | Number of events | 578 events | Single extractor |
Parada Geral (PG)Show verbatim quote (Table 3)Nº ocorrências PG 634 589 485 578 650 126 3062 | Not classifiable from the report | Number of events | 650 events | Single extractor |
Parada Geral (PG)Show verbatim quote (Table 3)Nº ocorrências PG 634 589 485 578 650 126 3062 | Not classifiable from the report | Number of events | 126 events | Single extractor |
Paradas por Falha (PF)Show verbatim quote (Table 3)Tempo Total de PF(H) 38 41 46 45 46 09 217 | Idling and minor stops (micro-stops) | Lost time | 45.0 h | Single extractor |
Paradas por Falha (PF)Show verbatim quote (Table 3)Tempo Total de PF(H) 38 41 46 45 46 09 217 | Idling and minor stops (micro-stops) | Lost time | 46.0 h | Single extractor |
Paradas por Falha (PF)Show verbatim quote (Table 3)Tempo Total de PF(H) 38 41 46 45 46 09 217 | Idling and minor stops (micro-stops) | Lost time | 9.00 h | Single extractor |
Paradas por Falha (PF)Show verbatim quote (Table 3)Nº ocorrências PF 277 265 293 294 299 60 1488 | Idling and minor stops (micro-stops) | Number of events | 294 events | Single extractor |
Paradas por Falha (PF)Show verbatim quote (Table 3)Nº ocorrências PF 277 265 293 294 299 60 1488 | Idling and minor stops (micro-stops) | Number of events | 299 events | Single extractor |
Paradas por Falha (PF)Show verbatim quote (Table 3)Nº ocorrências PF 277 265 293 294 299 60 1488 | Idling and minor stops (micro-stops) | Number of events | 60.0 events | Single extractor |
Paradas para Reparo (PR)Show verbatim quote (Table 3)Tempo Total de PR (H) 28 121 71 75 58 17 355 | Equipment failure (breakdowns) | Lost time | 75.0 h | Single extractor |
Paradas para Reparo (PR)Show verbatim quote (Table 3)Tempo Total de PR (H) 28 121 71 75 58 17 355 | Equipment failure (breakdowns) | Lost time | 58.0 h | Single extractor |
Paradas para Reparo (PR)Show verbatim quote (Table 3)Tempo Total de PR (H) 28 121 71 75 58 17 355 | Equipment failure (breakdowns) | Lost time | 17.0 h | Single extractor |
Paradas para Reparo (PR)Show verbatim quote (Table 3)Nº ocorrências PR 26 77 53 59 70 16 301 | Equipment failure (breakdowns) | Number of events | 59.0 events | Single extractor |
Paradas para Reparo (PR)Show verbatim quote (Table 3)Nº ocorrências PR 26 77 53 59 70 16 301 | Equipment failure (breakdowns) | Number of events | 70.0 events | Single extractor |
Paradas para Reparo (PR)Show verbatim quote (Table 3)Nº ocorrências PR 26 77 53 59 70 16 301 | Equipment failure (breakdowns) | Number of events | 16.0 events | Single extractor |
—Show verbatim quote (Table 3)MTBF 1,44 1,74 1,64 1,56 1,73 1,34 1,58 | Equipment failure (breakdowns) | Time between events | 1.56 h | Single extractor |
—Show verbatim quote (Table 3)MTBF 1,44 1,74 1,64 1,56 1,73 1,34 1,58 | Equipment failure (breakdowns) | Time between events | 1.73 h | Single extractor |
—Show verbatim quote (Table 3)MTBF 1,44 1,74 1,64 1,56 1,73 1,34 1,58 | Equipment failure (breakdowns) | Time between events | 1.34 h | Single extractor |
—Show verbatim quote (Table 3)MTTR 1,11 1,00 1,04 1,28 0,84 1,11 1,06 | Equipment failure (breakdowns) | Mean event duration | 1.28 h | Single extractor |
—Show verbatim quote (Table 3)MTTR 1,11 1,00 1,04 1,28 0,84 1,11 1,06 | Equipment failure (breakdowns) | Mean event duration | 0.840 h | Single extractor |
—Show verbatim quote (Table 3)MTTR 1,11 1,00 1,04 1,28 0,84 1,11 1,06 | Equipment failure (breakdowns) | Mean event duration | 1.11 h | Single extractor |
—Show verbatim quote (Table 3)Disponibilidade (%) 56,5 65,1 61,3 54.9 67,3 54,7 60,9 | none | Availability | 54.9 % | Single extractor |
—Show verbatim quote (Table 3)Disponibilidade (%) 56,5 65,1 61,3 54.9 67,3 54,7 60,9 | none | Availability | 67.3 % | Single extractor |
—Show verbatim quote (Table 3)Disponibilidade (%) 56,5 65,1 61,3 54.9 67,3 54,7 60,9 | none | Availability | 54.7 % | Single extractor |
—Show verbatim quote (Table 3)Rendimento (%) 83 76 81 80 80 74 80,2 | none | Performance | 80.0 % | Single extractor |
—Show verbatim quote (Table 3)Rendimento (%) 83 76 81 80 80 74 80,2 | none | Performance | 74.0 % | Single extractor |
Observation units
- Transport line (Nov 2020 - Jan 2021, baseline, before new PCM) · Conveying and accumulation · Baseline
- Transport line (Feb-Apr 2021, post new PCM) · Conveying and accumulation · After intervention