Eingeschlossene Studie
IMPLEMENTATION OF TPM ( TOTAL PRODUCTIVE MAINTENANCE) METHOD ON FILLING LINE 4 MACHINE TO REDUCE REJECTS AND DOWNTIME AT PT.XYZ
1Bibliografische Angaben
- Autoren
- Khusaeri
- Jahr
- 2025
- Publikationsorgan
- JKIE (Journal Knowledge Industrial Engineering)
- Land
- Indonesia
- Segment
- Erfrischungsgetränke, abgefülltes Wasser und Säfte
- Prozessfamilie
- Abfüll- und Verpackungslinie
- Studientyp
- Vorher-nachher-Intervention
- Extraktionsumfang
- Volltext
- Umfang
- 1 Werke · 1 Linien · 1 Maschinen
- Beobachtungszeitraum
- 85 Tage
- Datenerhebung
- manual_logs
- Intervention
Umfeld laut Studie anzeigen
PT. XYZ is one of the manufacturing companies engaged in various kinds of cold drinks (beverages), located in Pasuruan regency.
2Verzerrungsrisiko
Bewertet nach dem Schema des Protokolls: 2 geringe Bedenken, 1 einige Bedenken, 0 hohe Bedenken.
Gesamtpunktzahl 10Mittleres Risiko
| Kriterium | Punkte |
|---|---|
| Is the observed line, machine or plant described well enough to classify its segment, process and equipment?Product or sector is given but the equipment or process is only partly described. | 1 / 2 |
| Is the observation period long enough and reported?Period reported and at least 30 days of production (or at least 100 recorded events). | 2 / 2 |
| How were loss data collected?Manual logs or maintenance records with unknown completeness. | 1 / 2 |
| Are OEE, loading time and the loss categories defined explicitly?A standard definition is cited but its application is not shown. | 1 / 2 |
| Does the loss breakdown account for the total loss it claims to explain?The reported causes or categories sum to at least 90% of the stated total, or an explicit "other" class closes the balance. | 2 / 2 |
| Is there evidence of selective reporting of favourable results?Only post-intervention or only "best period" results are reported. | 0 / 2 |
| Are the reported numbers internally consistent?Small inconsistencies (2 to 10 percentage points) or values that cannot be cross-checked. | 1 / 2 |
| Could conflicts of interest or the source of the data bias the result?Academic or independent study, or conflicts declared and unrelated to the result. | 2 / 2 |
3Extrahierte Daten
Jeder Datenpunkt mit seiner Einordnung und dem wörtlichen Zitat, das ihn belegt.
| Berichtete Ursache | Verlustkategorie | Kennzahl | Wert | Extraktion |
|---|---|---|---|---|
SIP (Sanitation In Place)Wörtliches Zitat anzeigen (Conclusion, point 1 / Table 4.4)In the month February – May 2019 recorded existence minor idling downtime stop at line 4 , namely , CIP ( Cleaning In Place ) 2,509 minutes , SIP ( Sanitation In Place ) 1,943 minutes , stuck stamp on track 484 minutes , bottle stuck in the SIPA 322 divider , tilting was stuck for 277 minutes and the pallet ran out for 93 minutes . | Leerlauf und Kurzstillstände | Verlustzeit | 1.943 min | Durch Schiedsentscheid |
CIP (Cleaning In Place)Wörtliches Zitat anzeigen (Conclusion, point 1 / Table 4.4)In the month February – May 2019 recorded existence minor idling downtime stop at line 4 , namely , CIP ( Cleaning In Place ) 2,509 minutes , SIP ( Sanitation In Place ) 1,943 minutes , stuck stamp on track 484 minutes , bottle stuck in the SIPA 322 divider , tilting was stuck for 277 minutes and the pallet ran out for 93 minutes . | Leerlauf und Kurzstillstände | Verlustzeit | 2.509 min | Durch Schiedsentscheid |
—filling machineWörtliches Zitat anzeigen (Conclusion, point 3)obtained mark availability of 95.05%, the value performance of 82.07% and value Quality by 92.92% so that obtained OEE value of 76.92% | none | Qualität | 92,9 % | Beide Extraktionen übereinstimmend |
—filling machineWörtliches Zitat anzeigen (Conclusion, point 3)obtained mark availability of 95.05%, the value performance of 82.07% and value Quality by 92.92% so that obtained OEE value of 76.92% | none | Leistung | 82,1 % | Beide Extraktionen übereinstimmend |
—filling machineWörtliches Zitat anzeigen (Conclusion, point 3)obtained mark availability of 95.05%, the value performance of 82.07% and value Quality by 92.92% so that obtained OEE value of 76.92% | none | Verfügbarkeit | 95,1 % | Beide Extraktionen übereinstimmend |
—filling machineWörtliches Zitat anzeigen (Conclusion, point 3)obtained mark availability of 95.05%, the value performance of 82.07% and value Quality by 92.92% so that obtained OEE value of 76.92% who are under mark standard international that is 85.40%. | none | OEE | 76,9 % | Beide Extraktionen übereinstimmend |
stuck stamp on trackfilling machine (stamp/cap applicator)Wörtliches Zitat anzeigen (Conclusion, point 1 / Table 4.4)In the month February – May 2019 recorded existence minor idling downtime stop at line 4 , namely , CIP ( Cleaning In Place ) 2,509 minutes , SIP ( Sanitation In Place ) 1,943 minutes , stuck stamp on track 484 minutes , bottle stuck in the SIPA 322 divider , tilting was stuck for 277 minutes and the pallet ran out for 93 minutes . | Leerlauf und Kurzstillstände | Verlustzeit | 484 min | Durch Schiedsentscheid |
bottle stuck in the SIPA dividerSIPA dividerWörtliches Zitat anzeigen (Conclusion, point 1 / Table 4.4)In the month February – May 2019 recorded existence minor idling downtime stop at line 4 , namely , CIP ( Cleaning In Place ) 2,509 minutes , SIP ( Sanitation In Place ) 1,943 minutes , stuck stamp on track 484 minutes , bottle stuck in the SIPA 322 divider , tilting was stuck for 277 minutes and the pallet ran out for 93 minutes . | Leerlauf und Kurzstillstände | Verlustzeit | 322 min | Einfache Extraktion |
tilting was stucktilting slotWörtliches Zitat anzeigen (Conclusion, point 1 / Table 4.4)In the month February – May 2019 recorded existence minor idling downtime stop at line 4 , namely , CIP ( Cleaning In Place ) 2,509 minutes , SIP ( Sanitation In Place ) 1,943 minutes , stuck stamp on track 484 minutes , bottle stuck in the SIPA 322 divider , tilting was stuck for 277 minutes and the pallet ran out for 93 minutes . | Leerlauf und Kurzstillstände | Verlustzeit | 277 min | Einfache Extraktion |
pallet ran outWörtliches Zitat anzeigen (Conclusion, point 1 / Table 4.4)In the month February – May 2019 recorded existence minor idling downtime stop at line 4 , namely , CIP ( Cleaning In Place ) 2,509 minutes , SIP ( Sanitation In Place ) 1,943 minutes , stuck stamp on track 484 minutes , bottle stuck in the SIPA 322 divider , tilting was stuck for 277 minutes and the pallet ran out for 93 minutes . | Leerlauf und Kurzstillstände | Verlustzeit | 93,0 min | Einfache Extraktion |
D1 type fillingfilling machine line 4Wörtliches Zitat anzeigen (Conclusion, point 2)waste defect D1 type filling of 967 pcs, slanted lid of 1,586 pcs, folded TE of 5,204 pcs, closed perched 479 pcs, broken bride 5,551 pcs and without closed 12,279 pcs. | Prozessfehler (Ausschuss und Nacharbeit) | Anzahl der Ereignisse | 967 pcs | Einfache Extraktion |
slanted lidfilling machine line 4Wörtliches Zitat anzeigen (Conclusion, point 2)waste defect D1 type filling of 967 pcs, slanted lid of 1,586 pcs, folded TE of 5,204 pcs, closed perched 479 pcs, broken bride 5,551 pcs and without closed 12,279 pcs. | Prozessfehler (Ausschuss und Nacharbeit) | Anzahl der Ereignisse | 1.586 pcs | Einfache Extraktion |
folded TEfilling machine line 4Wörtliches Zitat anzeigen (Conclusion, point 2)waste defect D1 type filling of 967 pcs, slanted lid of 1,586 pcs, folded TE of 5,204 pcs, closed perched 479 pcs, broken bride 5,551 pcs and without closed 12,279 pcs. | Prozessfehler (Ausschuss und Nacharbeit) | Anzahl der Ereignisse | 5.204 pcs | Einfache Extraktion |
closed perchedfilling machine line 4Wörtliches Zitat anzeigen (Conclusion, point 2)waste defect D1 type filling of 967 pcs, slanted lid of 1,586 pcs, folded TE of 5,204 pcs, closed perched 479 pcs, broken bride 5,551 pcs and without closed 12,279 pcs. | Prozessfehler (Ausschuss und Nacharbeit) | Anzahl der Ereignisse | 479 pcs | Einfache Extraktion |
broken bridefilling machine line 4Wörtliches Zitat anzeigen (Conclusion, point 2)waste defect D1 type filling of 967 pcs, slanted lid of 1,586 pcs, folded TE of 5,204 pcs, closed perched 479 pcs, broken bride 5,551 pcs and without closed 12,279 pcs. | Prozessfehler (Ausschuss und Nacharbeit) | Anzahl der Ereignisse | 5.551 pcs | Einfache Extraktion |
without closedfilling machine line 4Wörtliches Zitat anzeigen (Conclusion, point 2)waste defect D1 type filling of 967 pcs, slanted lid of 1,586 pcs, folded TE of 5,204 pcs, closed perched 479 pcs, broken bride 5,551 pcs and without closed 12,279 pcs. | Prozessfehler (Ausschuss und Nacharbeit) | Anzahl der Ereignisse | 12.279 pcs | Einfache Extraktion |
without closefilling machine line 4Wörtliches Zitat anzeigen (Section 4, below Table 4.1)Example : reject without close in week 48 = 2821/11775x100%=1.938089172=1.9% | Prozessfehler (Ausschuss und Nacharbeit) | Anteil an den Verlustereignissen | 1,90 % | Einfache Extraktion |
Beobachtungseinheiten
- Line 4 filling machine · Abfüllen · Ausgangslage