foratvise
Get Started

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 64 % of the line's lost time. Reported by 1 of the 131 studies that could observe it (sparse evidence).

What happens

Fouling, scaling or wear inside the boiler reduces heat transfer efficiency and the stability of steam pressure and temperature delivered to the plant. Downstream thermal unit operations then have to run below their design rate to stay within process limits, and product processed under unstable steam conditions can fail quality checks and require rework.

What is done about it

Apply a preventive cleaning, descaling and water-treatment program for the boiler, and monitor heat transfer and combustion efficiency trends to schedule interventions before performance drifts outside acceptable limits. Stabilize steam header control loops and size buffer capacity so downstream processes are decoupled from short-term boiler fluctuations.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.7% [0.1–1.8%]
Expected share of lost time
0.4% [0.1–1.1%]
Share of lost time when present
64% [51–76%]
Studies / units
131 / 165
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.8% [0.1–2.7%]13 studies
  • Soft drinks, bottled water and juices
    0.7% [0.1–2.3%]26 studies
  • Brewing, wine and spirits
    0.7% [0.1–2.5%]12 studies
  • Bakery and pasta
    0.7% [0.1–2.3%]25 studies
  • Meat, poultry and seafood
    0.8% [0.1–2.7%]9 studies
  • Fruit and vegetable processing
    0.8% [0.1–2.8%]7 studies
  • Grain and oilseed milling
    1.1% [0.1–3.7%]7 studies
  • Sugar and confectionery
    0.7% [0.1–2.6%]9 studies
  • Snacks, coffee, tea and other foods
    0.7% [0.1–2.9%]5 studies
  • Animal feed and pet food
    0.8% [0.1–2.6%]7 studies
  • Food manufacturing (unspecified or mixed)
    0.7% [0.1–2.4%]11 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

Fouling, scaling or wear inside the boiler reduces heat transfer efficiency and the stability of steam pressure and temperature delivered to the plant. Downstream thermal unit operations then have to run below their design rate to stay within process limits, and product processed under unstable steam conditions can fail quality checks and require rework.

How it looks in SCADA data

Engineering guidance

SCADA shows steam header pressure or temperature drifting or oscillating outside setpoint, boiler firing rate or fuel consumption rising without a matching increase in steam output, and line speed setpoints reduced on downstream equipment that track these utility signals. MES quality data shows correlated upticks in rework or downgrade events on batches processed during periods of unstable steam supply.

Countermeasure

Engineering guidance

Apply a preventive cleaning, descaling and water-treatment program for the boiler, and monitor heat transfer and combustion efficiency trends to schedule interventions before performance drifts outside acceptable limits. Stabilize steam header control loops and size buffer capacity so downstream processes are decoupled from short-term boiler fluctuations.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Share of lost time: 0 % · as reported: “rework losses”
    Show verbatim quote
    From the analysis of the six big losses, it is known that the causes of the low OEE value are reduced speed losses by 79.01%, breakdown by 9.17%, idling minor stoppages 0.62%, setup and adjustment 0.67%, scrap/yield losses 10.51% and rework losses 0%.
  2. Share of lost time: 79.0 % · as reported: “reduced speed losses”
    Show verbatim quote
    From the analysis of the six big losses, it is known that the causes of the low OEE value are reduced speed losses by 79.01%, breakdown by 9.17%, idling minor stoppages 0.62%, setup and adjustment 0.67%, scrap/yield losses 10.51% and rework losses 0%.