foratvise
Get Started
Setup and adjustments

Equipment calibration/adjustment error

Setup and adjustmentsAvailabilityWhole line or unspecified equipment

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 57 % of the line's lost time. Reported by 2 of the 127 studies that could observe it (limited evidence).

What happens

An operator or technician sets machine parameters, sensors or mechanical references incorrectly during changeover or routine adjustment, often because the task was assigned to personnel without the right skill or because no standard procedure was followed. The resulting mis-calibration leaves the equipment running outside its intended operating window, so the line stops or must be readjusted before stable production resumes.

What is done about it

Define and enforce standardized calibration/adjustment procedures with checklists and reference setpoints, assign the task only to trained and qualified personnel, and use quick-set tools or automated calibration routines to reduce dependence on manual judgement. Verify setup against a reference standard before releasing the line to run.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.7% [0.2–1.7%]
Expected share of lost time
0.4% [0.1–1.0%]
Share of lost time when present
57% [44–67%]
Studies / units
127 / 161
Evidence grade
C

Grade C: 2 to 4 studies, or an interval wider than 0.35.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.8% [0.1–2.7%]13 studies
  • Soft drinks, bottled water and juices
    0.7% [0.1–2.2%]26 studies
  • Brewing, wine and spirits
    0.8% [0.1–2.7%]11 studies
  • Bakery and pasta
    1.0% [0.1–3.1%]24 studies
  • Meat, poultry and seafood
    0.8% [0.1–2.7%]9 studies
  • Fruit and vegetable processing
    0.8% [0.1–3.0%]7 studies
  • Grain and oilseed milling
    0.8% [0.1–2.9%]6 studies
  • Sugar and confectionery
    0.8% [0.1–2.5%]9 studies
  • Snacks, coffee, tea and other foods
    1.1% [0.1–3.8%]5 studies
  • Animal feed and pet food
    0.8% [0.1–2.8%]7 studies
  • Food manufacturing (unspecified or mixed)
    0.8% [0.1–2.8%]10 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

An operator or technician sets machine parameters, sensors or mechanical references incorrectly during changeover or routine adjustment, often because the task was assigned to personnel without the right skill or because no standard procedure was followed. The resulting mis-calibration leaves the equipment running outside its intended operating window, so the line stops or must be readjusted before stable production resumes.

How it looks in SCADA data

Engineering guidance

Extended time in setup/adjustment or minor-stop machine states right after a changeover or shift handover, repeated short stops with the same alarm code, or parameter values (position, pressure, speed, timing) drifting outside tolerance bands recorded by the control system. Correlated starvation/blocking of upstream or downstream stations often follows the affected unit.

Countermeasure

Engineering guidance

Define and enforce standardized calibration/adjustment procedures with checklists and reference setpoints, assign the task only to trained and qualified personnel, and use quick-set tools or automated calibration routines to reduce dependence on manual judgement. Verify setup against a reference standard before releasing the line to run.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Lost time: 17.0 h · as reported: “Error en calibración/ajuste del equipo”
    Show verbatim quote
    Error en calibracion/ajuste del equipo 16.95 16%
  2. Share of lost time: 16.0 % · as reported: “Error en calibración/ajuste del equipo”
    Show verbatim quote
    Error en calibracion/ajuste del equipo 16.95 16%
  3. Share of lost time: 2.29 % · as reported: “Deficiente calibración de equipos”
    Show verbatim quote
    Deficiente calibración de equipos 533.28 2.29% 96.63%
  4. Lost time: 533 min · as reported: “Deficiente calibración de equipos”
    Show verbatim quote
    Deficiente calibración de equipos 533.28 2.29% 96.63%
  5. Share of lost time: 21.0 % · as reported: “Deficiente asignación de tareas”
    Show verbatim quote
    Deficiente asignación de tareas 4886.52 21.02% 60.87%
  6. Lost time: 4,887 min · as reported: “Deficiente asignación de tareas”
    Show verbatim quote
    Deficiente asignación de tareas 4886.52 21.02% 60.87%