Jam/blockage at coding or sealing station
In short
It appears in fewer than 1 of every 100 lines studied.
When it appears, it takes on average about 57 % of the line's lost time. Reported by 0 of the 120 studies that could observe it (sparse evidence).
What happens
Packaging material, product residue or a misaligned component becomes physically lodged in the coding head or the sealing jaws, preventing the mechanism from cycling and forcing the station into a blocked state. The obstruction is usually mechanical rather than a control fault, so the line stops until the blockage is manually cleared and the mechanism is reset.
What is done about it
Clear the physical obstruction, inspect and realign the coding head or sealing jaws, and verify material feed guides and tension settings. Implement a preventive maintenance routine to check wear parts and sensor cleanliness at these stations to reduce recurrence of blockages.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.4% [0.1–1.1%]
- Expected share of lost time
- 0.2% [0.0–0.6%]
- Share of lost time when present
- 57% [46–67%]
- Studies / units
- 120 / 162
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.4% [0.0–1.6%]18 studies
- Soft drinks, bottled water and juices0.4% [0.0–1.3%]44 studies
- Brewing, wine and spirits0.4% [0.0–1.5%]16 studies
- Bakery and pasta0.5% [0.0–1.9%]0 studies
- Meat, poultry and seafood0.5% [0.0–1.9%]6 studies
- Fruit and vegetable processing0.5% [0.0–1.7%]4 studies
- Grain and oilseed milling0.5% [0.0–1.8%]6 studies
- Sugar and confectionery0.5% [0.0–1.8%]3 studies
- Snacks, coffee, tea and other foods0.5% [0.0–1.7%]6 studies
- Animal feed and pet food0.5% [0.0–1.8%]4 studies
- Food manufacturing (unspecified or mixed)0.4% [0.0–1.7%]13 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidancePackaging material, product residue or a misaligned component becomes physically lodged in the coding head or the sealing jaws, preventing the mechanism from cycling and forcing the station into a blocked state. The obstruction is usually mechanical rather than a control fault, so the line stops until the blockage is manually cleared and the mechanism is reset.
How it looks in SCADA data
Engineering guidanceThe coding or sealing station reports a fault or blocked-state alarm, the machine status transitions to stopped with the specific station flagged, and cycle counters freeze while upstream stations continue running, causing blocking of upstream equipment and starvation downstream. Repeated short bursts of the same alarm code at that station are typical before a full stoppage.
Countermeasure
Engineering guidanceClear the physical obstruction, inspect and realign the coding head or sealing jaws, and verify material feed guides and tension settings. Implement a preventive maintenance routine to check wear parts and sensor cleanliness at these stations to reduce recurrence of blockages.
4Sources
- Integration of Overall Equipment Effectiveness and Six Sigma Approach to Minimize Product Defect and Machine Downtime (2023)Open sourceNumber of events: 1.00 events · as reported: “Block Sealing”
Show verbatim quote
Block Sealing 1
- Integration of Overall Equipment Effectiveness and Six Sigma Approach to Minimize Product Defect and Machine Downtime (2023)Open sourceNumber of events: 5.00 events · as reported: “Block Coding”
Show verbatim quote
Block Coding 5