Deflector position adjustment
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 56 % of the line's lost time. Reported by 1 of the 43 studies that could observe it (sparse evidence).
What happens
When a product or format change occurs, the deflector plate inside the milling (fibrizer) unit must be repositioned or re-angled to suit the new feed characteristics, so the equipment is taken out of production while operators manually loosen, move and re-secure the deflector and verify the new setting before resuming the run.
What is done about it
Apply SMED principles to the deflector adjustment: install calibrated scales, quick-release clamps or pre-set stops for each product format, and where feasible replace manual positioning with a motorized or guided actuator so the setting can be changed and verified without extended manual intervention.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.8% [0.1–2.3%]
- Expected share of lost time
- 0.4% [0.1–1.3%]
- Share of lost time when present
- 56% [43–67%]
- Studies / units
- 43 / 48
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.9% [0.1–3.7%]5 studies
- Soft drinks, bottled water and juices0.9% [0.1–3.8%]1 study
- Brewing, wine and spirits1.0% [0.1–4.0%]0 studies
- Bakery and pasta1.0% [0.1–3.8%]0 studies
- Meat, poultry and seafood1.0% [0.1–3.8%]0 studies
- Fruit and vegetable processing0.9% [0.1–3.5%]2 studies
- Grain and oilseed milling0.9% [0.1–3.6%]7 studies
- Sugar and confectionery1.3% [0.1–4.5%]10 studies
- Snacks, coffee, tea and other foods0.9% [0.1–3.3%]5 studies
- Animal feed and pet food0.9% [0.1–3.4%]6 studies
- Food manufacturing (unspecified or mixed)0.9% [0.1–3.3%]7 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceWhen a product or format change occurs, the deflector plate inside the milling (fibrizer) unit must be repositioned or re-angled to suit the new feed characteristics, so the equipment is taken out of production while operators manually loosen, move and re-secure the deflector and verify the new setting before resuming the run.
How it looks in SCADA data
Engineering guidanceThe line shows an extended setup or manual-mode state on the milling station with the drive motor stopped and zero throughput counts, often preceded by a changeover or product-code change event; the state duration is longer and more variable than typical minor stops, with no fault alarm raised.
Countermeasure
Engineering guidanceApply SMED principles to the deflector adjustment: install calibrated scales, quick-release clamps or pre-set stops for each product format, and where feasible replace manual positioning with a motorized or guided actuator so the setting can be changed and verified without extended manual intervention.
4Sources
- Evaluasi Kinerja Mesin Giling Menggunakan Metode OEE dalam Upaya Pengurangan Six Big Losses di PT PG Candi Baru Sidoarjo (2025)Open sourceLost time: 5.94 h · as reported: “Setup and Adjustment”
Show verbatim quote
Jumlah 5,94 5,94 0,00 0,00 0,00 16,20