In short
It appears in fewer than 1 of every 100 lines studied.
When it appears, it takes on average about 56 % of the line's lost time. Reported by 0 of the 120 studies that could observe it (sparse evidence).
What happens
During a changeover or startup the filling valve or fill-volume unit must be reconfigured and fine-tuned to deliver the new target fill level or weight, requiring manual or recipe-driven adjustment of stroke, timing or flow parameters before stable dosing is reached. This adjustment time is non-productive and occurs between the last good unit of the previous run and the first good unit at the new setting.
What is done about it
Use recipe-driven automatic setpoint recall for each product/format so the fill volume is loaded electronically instead of adjusted manually, and validate with inline checkweighing or volumetric feedback to shorten the fine-tuning cycle; standardize changeover procedures with pre-set reference values.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.3% [0.1–1.0%]
- Expected share of lost time
- 0.2% [0.0–0.5%]
- Share of lost time when present
- 56% [44–67%]
- Studies / units
- 120 / 162
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.4% [0.0–1.4%]18 studies
- Soft drinks, bottled water and juices0.3% [0.0–1.1%]44 studies
- Brewing, wine and spirits0.4% [0.0–1.4%]16 studies
- Bakery and pasta0.4% [0.0–1.6%]0 studies
- Meat, poultry and seafood0.4% [0.0–1.6%]6 studies
- Fruit and vegetable processing0.4% [0.0–1.6%]4 studies
- Grain and oilseed milling0.4% [0.0–1.5%]6 studies
- Sugar and confectionery0.4% [0.0–1.5%]3 studies
- Snacks, coffee, tea and other foods0.4% [0.0–1.5%]6 studies
- Animal feed and pet food0.4% [0.0–1.6%]4 studies
- Food manufacturing (unspecified or mixed)0.4% [0.0–1.5%]13 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceDuring a changeover or startup the filling valve or fill-volume unit must be reconfigured and fine-tuned to deliver the new target fill level or weight, requiring manual or recipe-driven adjustment of stroke, timing or flow parameters before stable dosing is reached. This adjustment time is non-productive and occurs between the last good unit of the previous run and the first good unit at the new setting.
How it looks in SCADA data
Engineering guidanceSCADA/MES shows a changeover or setup machine state on the filler with the fill-volume setpoint parameter being modified multiple times, trial cycles with no case/pallet count increment, and a gap in good-unit counters while the valve runs in adjustment or manual mode.
Countermeasure
Engineering guidanceUse recipe-driven automatic setpoint recall for each product/format so the fill volume is loaded electronically instead of adjusted manually, and validate with inline checkweighing or volumetric feedback to shorten the fine-tuning cycle; standardize changeover procedures with pre-set reference values.
4Sources
- Efficiency Improvement of Glass Bottle Filler Machine Using Autonomous Maintenance-A Case Study (2025)Open sourceLost time: 47.0 min · as reported: “Fill volume setting”
Show verbatim quote
Fill volume setting 0 0 0 0 0 47 47 3.21
- Efficiency Improvement of Glass Bottle Filler Machine Using Autonomous Maintenance-A Case Study (2025)Open sourceShare of lost time: 3.21 % · as reported: “Fill volume setting”
Show verbatim quote
Fill volume setting 0 0 0 0 0 47 47 3.21
- Efficiency Improvement of Glass Bottle Filler Machine Using Autonomous Maintenance-A Case Study (2025)Open sourceLost time: 47.0 min · as reported: “Fill volume setting”
Show verbatim quote
10 | Fill volume setting | 0 | 0 | 0 | 0 | 0 | 47 | 47 | 3.21