Included study
Efficiency Improvement of Glass Bottle Filler Machine Using Autonomous Maintenance-A Case Study
1Bibliographic record
- Authors
- Sajin M C, Sajith Babu, Akhil Devaraj, Sony Kurian, Joby George
- Year
- 2025
- Venue
- —
- Country
- India
- Segment
- Soft drinks, bottled water and juices
- Process family
- Filling and packaging line
- Study type
- Before/after intervention
- Extraction scope
- Full text
- Size
- 1 plants · 1 lines · 1 machines
- Observation period
- 180 days
- Data collection
- maintenance_records
- Intervention
Show the setting as described by the study
This study is conducted on the glass bottle filler machine which is a critical machine in a leading beverages manufacturing company.
2Risk of bias
Scored with the rubric of the protocol: 2 low concern, 1 some concerns, 0 high concern.
Total score 13Low risk
| Item | Score |
|---|---|
| Is the observed line, machine or plant described well enough to classify its segment, process and equipment?Product, process and equipment are all described. | 2 / 2 |
| Is the observation period long enough and reported?Period reported and at least 30 days of production (or at least 100 recorded events). | 2 / 2 |
| How were loss data collected?Manual logs or maintenance records with unknown completeness. | 1 / 2 |
| Are OEE, loading time and the loss categories defined explicitly?Formulae or definitions are given for the reported metrics, including what counts as planned time. | 2 / 2 |
| Does the loss breakdown account for the total loss it claims to explain?The reported causes or categories sum to at least 90% of the stated total, or an explicit "other" class closes the balance. | 2 / 2 |
| Is there evidence of selective reporting of favourable results?Observational study, or intervention study that reports baseline and post-intervention data with the same method. | 2 / 2 |
| Are the reported numbers internally consistent?Small inconsistencies (2 to 10 percentage points) or values that cannot be cross-checked. | 1 / 2 |
| Could conflicts of interest or the source of the data bias the result?Authors are employees of the plant or of an equipment/software vendor; no declaration. | 1 / 2 |
3Extracted data
Each datum with its classification and the verbatim quote that states it.
| Reported cause | Loss category | Metric | Value | Extraction |
|---|---|---|---|---|
Discharge backup sensor malfunctiondischarge sensorShow verbatim quote (Table 1)Discharge backup sensor malfunction 0 4 0 0 0 0 4 0.27 | Equipment failure (breakdowns) | Lost time | 4.00 min | Both extractors agreed |
Carousel star wheel timing disturbstarwheelShow verbatim quote (Table 1)Carousel star wheel timing disturb 0 3 0 0 0 0 3 0.20 | Equipment failure (breakdowns) | Lost time | 3.00 min | Both extractors agreed |
Crown sorter sensor malfunctioncrown sorterShow verbatim quote (Table 1)Crown sorter sensor malfunction 0 8 0 0 0 0 8 0.55 | Equipment failure (breakdowns) | Lost time | 8.00 min | Both extractors agreed |
Discharge starwheel timingdischarge starwheelShow verbatim quote (Table 1)Discharge starwheel timing 0 3 0 0 0 0 3 0.20 | Equipment failure (breakdowns) | Lost time | 3.00 min | Both extractors agreed |
Filler centering bell unit tripcentering bellShow verbatim quote (Table 1)Filler centering bell unit trip 4 2 3 0 0 0 9 0.61 | Equipment failure (breakdowns) | Lost time | 9.00 min | Both extractors agreed |
BBT change over delayShow verbatim quote (Table 1)BBT change over delay 3 0 5 0 0 0 8 0.55 | Setup and adjustments | Lost time | 8.00 min | Both extractors agreed |
HIP problemShow verbatim quote (Table 1)HIP problem 0 0 10 0 0 0 10 0.68 | Equipment failure (breakdowns) | Lost time | 10.0 min | Adjudicated |
ABIBUS fault fillerfillerShow verbatim quote (Table 1)ABIBUS fault filler 0 0 0 0 20 0 20 1.37 | Equipment failure (breakdowns) | Lost time | 20.0 min | Single extractor |
ABIBUS fault fillerfillerShow verbatim quote (Table 1)ABIBUS fault filler 0 0 0 0 20 0 20 1.37 | Equipment failure (breakdowns) | Share of lost time | 1.37 % | Single extractor |
BBT change over delayShow verbatim quote (Table 1)BBT change over delay 3 0 5 0 0 0 8 0.55 | Setup and adjustments | Share of lost time | 0.550 % | Single extractor |
Carousel star wheel timing disturbstarwheelShow verbatim quote (Table 1)Carousel star wheel timing disturb 0 3 0 0 0 0 3 0.20 | Equipment failure (breakdowns) | Share of lost time | 0.200 % | Single extractor |
Crown hopper unit stripcrown hopperShow verbatim quote (Table 1)Crown hopper unit strip 0 10 0 0 0 14 24 1.64 | Equipment failure (breakdowns) | Lost time | 24.0 min | Single extractor |
Crown hopper unit stripcrown hopperShow verbatim quote (Table 1)Crown hopper unit strip 0 10 0 0 0 14 24 1.64 | Equipment failure (breakdowns) | Share of lost time | 1.64 % | Single extractor |
Crown stuckcrownerShow verbatim quote (Table 1)Crown stuck 82 88 136 95 102 158 616 42.08 | Idling and minor stops (micro-stops) | Lost time | 616 min | Single extractor |
Crown stuckcrownerShow verbatim quote (Table 1)Crown stuck 82 88 136 95 102 158 616 42.08 | Idling and minor stops (micro-stops) | Share of lost time | 42.1 % | Single extractor |
Crowner head settingcrowner headShow verbatim quote (Table 1)Crowner head setting 0 0 0 10 5 0 15 1.02 | Setup and adjustments | Lost time | 15.0 min | Single extractor |
Crowner head settingcrowner headShow verbatim quote (Table 1)Crowner head setting 0 0 0 10 5 0 15 1.02 | Setup and adjustments | Share of lost time | 1.02 % | Single extractor |
Discharge backup sensor malfunctiondischarge sensorShow verbatim quote (Table 1)Discharge backup sensor malfunction 0 4 0 0 0 0 4 0.27 | Equipment failure (breakdowns) | Share of lost time | 0.270 % | Single extractor |
Discharge jamdischargeShow verbatim quote (Table 1)Discharge jam 0 0 0 10 6 9 25 1.71 | Idling and minor stops (micro-stops) | Lost time | 25.0 min | Single extractor |
Discharge jamdischargeShow verbatim quote (Table 1)Discharge jam 0 0 0 10 6 9 25 1.71 | Idling and minor stops (micro-stops) | Share of lost time | 1.71 % | Single extractor |
Discharge starwheel timingdischarge starwheelShow verbatim quote (Table 1)Discharge starwheel timing 0 3 0 0 0 0 3 0.20 | Equipment failure (breakdowns) | Share of lost time | 0.200 % | Single extractor |
Fill volume settingfilling valveShow verbatim quote (Table 1)Fill volume setting 0 0 0 0 0 47 47 3.21 | Setup and adjustments | Lost time | 47.0 min | Single extractor |
Fill volume settingfilling valveShow verbatim quote (Table 1)Fill volume setting 0 0 0 0 0 47 47 3.21 | Setup and adjustments | Share of lost time | 3.21 % | Single extractor |
Filler centering bell unit tripcentering bellShow verbatim quote (Table 1)Filler centering bell unit trip 4 2 3 0 0 0 9 0.61 | Equipment failure (breakdowns) | Share of lost time | 0.610 % | Single extractor |
Filler discharge backupdischargeShow verbatim quote (Table 1)Filler discharge backup 0 2 0 0 0 6 8 0.55 | Idling and minor stops (micro-stops) | Lost time | 8.00 min | Single extractor |
Filler discharge backupdischargeShow verbatim quote (Table 1)Filler discharge backup 0 2 0 0 0 6 8 0.55 | Idling and minor stops (micro-stops) | Share of lost time | 0.550 % | Single extractor |
Infeed jaminfeedShow verbatim quote (Table 1)Infeed jam 6 8 14 7 12 13 71 4.85 | Idling and minor stops (micro-stops) | Lost time | 71.0 min | Single extractor |
Infeed jaminfeedShow verbatim quote (Table 1)Infeed jam 6 8 14 7 12 13 71 4.85 | Idling and minor stops (micro-stops) | Share of lost time | 4.85 % | Single extractor |
Infeed unit tripinfeed unitShow verbatim quote (Table 1)Infeed unit trip 8 1 2 0 0 5 16 1.09 | Equipment failure (breakdowns) | Lost time | 16.0 min | Single extractor |
Infeed unit tripinfeed unitShow verbatim quote (Table 1)Infeed unit trip 8 1 2 0 0 5 16 1.09 | Equipment failure (breakdowns) | Share of lost time | 1.09 % | Single extractor |
Infeed worm timing settinginfeed wormShow verbatim quote (Table 1)Infeed worm timing setting 4 8 0 0 0 16 28 1.91 | Setup and adjustments | Lost time | 28.0 min | Single extractor |
Infeed worm timing settinginfeed wormShow verbatim quote (Table 1)Infeed worm timing setting 4 8 0 0 0 16 28 1.91 | Setup and adjustments | Share of lost time | 1.91 % | Single extractor |
Ring pull settingcrownerShow verbatim quote (Table 1)Ring pull setting 0 4 8 0 30 5 47 3.21 | Setup and adjustments | Lost time | 47.0 min | Single extractor |
Ring pull settingcrownerShow verbatim quote (Table 1)Ring pull setting 0 4 8 0 30 5 47 3.21 | Setup and adjustments | Share of lost time | 3.21 % | Single extractor |
Speed lossfillerShow verbatim quote (Table 1)Speed loss 244 166 46 3 0 0 459 31.35 | Reduced speed | Lost time | 459 min | Single extractor |
Speed lossfillerShow verbatim quote (Table 1)Speed loss 244 166 46 3 0 0 459 31.35 | Reduced speed | Share of lost time | 31.4 % | Single extractor |
TPO settingcapperShow verbatim quote (Table 1)TPO setting 0 3 0 5 0 0 8 0.55 | Setup and adjustments | Lost time | 8.00 min | Single extractor |
TPO settingcapperShow verbatim quote (Table 1)TPO setting 0 3 0 5 0 0 8 0.55 | Setup and adjustments | Share of lost time | 0.550 % | Single extractor |
Vent tube bent correction/changevent tubeShow verbatim quote (Table 1)Vent tube bent correction/change 0 2 0 0 10 23 35 2.39 | Equipment failure (breakdowns) | Lost time | 35.0 min | Single extractor |
Vent tube bent correction/changevent tubeShow verbatim quote (Table 1)Vent tube bent correction/change 0 2 0 0 10 23 35 2.39 | Equipment failure (breakdowns) | Share of lost time | 2.39 % | Single extractor |
HIP problemShow verbatim quote (Table 1)HIP problem 0 0 10 0 0 0 10 0.68 | Not classifiable from the report | Share of lost time | 0.680 % | Single extractor |
Crown sorter sensor malfunctioncrown sorterShow verbatim quote (Table 1)Crown sorter sensor malfunction 0 8 0 0 0 0 8 0.55 | Equipment failure (breakdowns) | Share of lost time | 0.550 % | Single extractor |
—fillerShow verbatim quote (Table 3)Total breakdown time (min) 125 174 307 | Equipment failure (breakdowns) | Lost time | 125 min | Single extractor |
—fillerShow verbatim quote (Table 3)Total break downs 38 54 98 | Equipment failure (breakdowns) | Number of events | 38.0 events | Single extractor |
—fillerShow verbatim quote (Table 3)MTBF (min) 206.16 162.81 151.85 | Equipment failure (breakdowns) | Time between events | 206 min | Single extractor |
—fillerShow verbatim quote (Table 3)MTTR (min) 3.29 3.22 3.13 | Equipment failure (breakdowns) | Mean event duration | 3.29 min | Single extractor |
—fillerShow verbatim quote (Table 3)OEE (%) 86.85 87.81 85.16 | none | OEE | 86.9 % | Single extractor |
—fillerShow verbatim quote (Table 3)Total breakdown time (min) 125 174 307 | Equipment failure (breakdowns) | Lost time | 174 min | Single extractor |
—fillerShow verbatim quote (Table 3)Total break downs 38 54 98 | Equipment failure (breakdowns) | Number of events | 54.0 events | Single extractor |
—fillerShow verbatim quote (Table 3)MTBF (min) 206.16 162.81 151.85 | Equipment failure (breakdowns) | Time between events | 163 min | Single extractor |
—fillerShow verbatim quote (Table 3)MTTR (min) 3.29 3.22 3.13 | Equipment failure (breakdowns) | Mean event duration | 3.22 min | Single extractor |
—fillerShow verbatim quote (Table 3)OEE (%) 86.85 87.81 85.16 | none | OEE | 87.8 % | Single extractor |
—fillerShow verbatim quote (Table 3)Total breakdown time (min) 125 174 307 | Equipment failure (breakdowns) | Lost time | 307 min | Single extractor |
—fillerShow verbatim quote (Table 3)Total break downs 38 54 98 | Equipment failure (breakdowns) | Number of events | 98.0 events | Single extractor |
—fillerShow verbatim quote (Table 3)MTBF (min) 206.16 162.81 151.85 | Equipment failure (breakdowns) | Time between events | 152 min | Single extractor |
—fillerShow verbatim quote (Table 3)MTTR (min) 3.29 3.22 3.13 | Equipment failure (breakdowns) | Mean event duration | 3.13 min | Single extractor |
—fillerShow verbatim quote (Table 3)OEE (%) 86.85 87.81 85.16 | none | OEE | 85.2 % | Single extractor |
Crown hopper unit stripcrown hopper unitShow verbatim quote (Table 1, row 4)4 | Crown hopper unit strip | 0 | 10 | 0 | 0 | 0 | 14 | 24 | 1.64 | Equipment failure (breakdowns) | Lost time | 10.0 min | Single extractor |
Filler discharge backupfiller dischargeShow verbatim quote (Table 1, row 12)12 | Filler discharge backup | 0 | 2 | 0 | 0 | 0 | 6 | 8 | 0.55 | Equipment failure (breakdowns) | Lost time | 2.00 min | Single extractor |
TPO settingShow verbatim quote (Table 1, row 18)18 | TPO setting | 0 | 3 | 0 | 5 | 0 | 0 | 8 | 0.55 | Setup and adjustments | Lost time | 3.00 min | Single extractor |
Vent tube bent correction/changevent tubeShow verbatim quote (Table 1, row 19)19 | Vent tube bent correction/change | 0 | 2 | 0 | 0 | 10 | 23 | 35 | 2.39 | Equipment failure (breakdowns) | Lost time | 2.00 min | Single extractor |
ABIBUS fault fillerfillerShow verbatim quote (Table 1, row 1)1 | ABIBUS fault filler | 0 | 0 | 0 | 0 | 20 | 0 | 20 | 1.37 | Equipment failure (breakdowns) | Lost time | 20.0 min | Single extractor |
Crown hopper unit stripcrown hopper unitShow verbatim quote (Table 1, row 4)4 | Crown hopper unit strip | 0 | 10 | 0 | 0 | 0 | 14 | 24 | 1.64 | Equipment failure (breakdowns) | Lost time | 14.0 min | Single extractor |
Crowner head settingcrowner headShow verbatim quote (Table 1, row 6)6 | Crowner head setting | 0 | 0 | 0 | 10 | 5 | 0 | 15 | 1.02 | Setup and adjustments | Lost time | 15.0 min | Single extractor |
Discharge jamdischarge areaShow verbatim quote (Table 1, row 8)8 | Discharge jam | 0 | 0 | 0 | 10 | 6 | 9 | 25 | 1.71 | Idling and minor stops (micro-stops) | Lost time | 25.0 min | Single extractor |
Fill volume settingfill volume unitShow verbatim quote (Table 1, row 10)10 | Fill volume setting | 0 | 0 | 0 | 0 | 0 | 47 | 47 | 3.21 | Setup and adjustments | Lost time | 47.0 min | Single extractor |
Filler discharge backupfiller dischargeShow verbatim quote (Table 1, row 12)12 | Filler discharge backup | 0 | 2 | 0 | 0 | 0 | 6 | 8 | 0.55 | Equipment failure (breakdowns) | Lost time | 6.00 min | Single extractor |
Infeed unit tripinfeed unitShow verbatim quote (Table 1, row 14)14 | Infeed unit trip | 8 | 1 | 2 | 0 | 0 | 5 | 16 | 1.09 | Equipment failure (breakdowns) | Lost time | 5.00 min | Single extractor |
Infeed worm timing settinginfeed wormShow verbatim quote (Table 1, row 15)15 | Infeed worm timing setting | 4 | 8 | 0 | 0 | 0 | 16 | 28 | 1.91 | Setup and adjustments | Lost time | 16.0 min | Single extractor |
Speed lossfiller machineShow verbatim quote (Table 1, row 17)17 | Speed loss | 244 | 166 | 46 | 3 | 0 | 0 | 459 | 31.35 | Reduced speed | Lost time | 3.00 min | Single extractor |
TPO settingShow verbatim quote (Table 1, row 18)18 | TPO setting | 0 | 3 | 0 | 5 | 0 | 0 | 8 | 0.55 | Setup and adjustments | Lost time | 5.00 min | Single extractor |
Observation units
- Glass bottle filler machine · Filling · Baseline
- Glass bottle filler machine · Filling · After intervention
- Filler machine · Filling · Baseline
- Filler machine · Filling · After intervention

