Equipment failure (breakdowns)

Filler discharge jam or backup

Equipment failure (breakdowns)AvailabilityFilling

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 58 % of the line's lost time. Reported by 2 of the 120 studies that could observe it (limited evidence).

What happens

Containers leaving the filler bowl fail to transfer smoothly to the outfeed conveyor because the discharge starwheel loses timing with the infeed/outfeed pitch, the exit guide rails are misaligned, or the backup photoeye/sensor fails to detect accumulated containers. The resulting misalignment or false signal causes containers to collide, tip or stall at the discharge point, which can escalate from a simple jam cleared by the operator to a mechanical fault requiring maintenance intervention on the starwheel drive or sensor assembly.

What is done about it

Establish a preventive maintenance routine that checks and recalibrates starwheel timing, guide rail alignment and backup sensor function on a scheduled basis, and install redundant or self-cleaning sensors less prone to fouling. Train operators to clear minor jams quickly and log recurring locations so engineering can prioritize mechanical adjustment or component replacement before failures escalate.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.7% [0.2–1.9%]
Expected share of lost time
0.4% [0.1–1.1%]
Share of lost time when present
58% [46–68%]
Studies / units
120 / 162
Evidence grade
C

Grade C: 2 to 4 studies, or an interval wider than 0.35.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.8% [0.1–2.6%]18 studies
  • Soft drinks, bottled water and juices
    1.1% [0.2–3.1%]44 studies
  • Brewing, wine and spirits
    0.8% [0.1–2.8%]16 studies
  • Bakery and pasta
    0.9% [0.1–3.3%]0 studies
  • Meat, poultry and seafood
    0.8% [0.1–2.9%]6 studies
  • Fruit and vegetable processing
    0.8% [0.1–3.0%]4 studies
  • Grain and oilseed milling
    0.9% [0.1–3.1%]6 studies
  • Sugar and confectionery
    0.9% [0.1–3.2%]3 studies
  • Snacks, coffee, tea and other foods
    0.8% [0.1–3.1%]6 studies
  • Animal feed and pet food
    0.9% [0.1–3.0%]4 studies
  • Food manufacturing (unspecified or mixed)
    0.8% [0.1–2.7%]13 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

Containers leaving the filler bowl fail to transfer smoothly to the outfeed conveyor because the discharge starwheel loses timing with the infeed/outfeed pitch, the exit guide rails are misaligned, or the backup photoeye/sensor fails to detect accumulated containers. The resulting misalignment or false signal causes containers to collide, tip or stall at the discharge point, which can escalate from a simple jam cleared by the operator to a mechanical fault requiring maintenance intervention on the starwheel drive or sensor assembly.

How it looks in SCADA data

Engineering guidance

MES/SCADA shows repeated short stop events logged against the filler discharge or outfeed station, often paired with a backup-sensor alarm or starwheel position/servo fault code. Downstream equipment shows starvation (idle waiting for product) while the filler itself cycles in a stopped or fault state, and event duration distribution typically separates short operator-cleared stops from longer stops tagged as equipment fault.

Countermeasure

Engineering guidance

Establish a preventive maintenance routine that checks and recalibrates starwheel timing, guide rail alignment and backup sensor function on a scheduled basis, and install redundant or self-cleaning sensors less prone to fouling. Train operators to clear minor jams quickly and log recurring locations so engineering can prioritize mechanical adjustment or component replacement before failures escalate.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Lost time: 4.00 min · as reported: “Discharge backup sensor malfunction”
    Show verbatim quote
    Discharge backup sensor malfunction 0 4 0 0 0 0 4 0.27
  2. Lost time: 3.00 min · as reported: “Discharge starwheel timing”
    Show verbatim quote
    Discharge starwheel timing 0 3 0 0 0 0 3 0.20
  3. Share of lost time: 0.270 % · as reported: “Discharge backup sensor malfunction”
    Show verbatim quote
    Discharge backup sensor malfunction 0 4 0 0 0 0 4 0.27
  4. Lost time: 25.0 min · as reported: “Discharge jam”
    Show verbatim quote
    Discharge jam 0 0 0 10 6 9 25 1.71
  5. Share of lost time: 1.71 % · as reported: “Discharge jam”
    Show verbatim quote
    Discharge jam 0 0 0 10 6 9 25 1.71
  6. Share of lost time: 0.200 % · as reported: “Discharge starwheel timing”
    Show verbatim quote
    Discharge starwheel timing 0 3 0 0 0 0 3 0.20
  7. Lost time: 8.00 min · as reported: “Filler discharge backup”
    Show verbatim quote
    Filler discharge backup 0 2 0 0 0 6 8 0.55
  8. Share of lost time: 0.550 % · as reported: “Filler discharge backup”
    Show verbatim quote
    Filler discharge backup 0 2 0 0 0 6 8 0.55
  9. Lost time: 2.00 min · as reported: “Filler discharge backup”
    Show verbatim quote
    12 | Filler discharge backup | 0 | 2 | 0 | 0 | 0 | 6 | 8 | 0.55
  10. Lost time: 25.0 min · as reported: “Discharge jam”
    Show verbatim quote
    8 | Discharge jam | 0 | 0 | 0 | 10 | 6 | 9 | 25 | 1.71
  11. Lost time: 6.00 min · as reported: “Filler discharge backup”
    Show verbatim quote
    12 | Filler discharge backup | 0 | 2 | 0 | 0 | 0 | 6 | 8 | 0.55
  12. Lost time: 200 min · as reported: “guide discharge filler”
    Show verbatim quote
    guide discharge filler 7 200 100 3088 89.28 87.82
  13. Number of events: 7.00 events · as reported: “guide discharge filler”
    Show verbatim quote
    guide discharge filler 7 200 100 3088 89.28 87.82
  14. Lost time: 95.0 min · as reported: “discharge filler”
    Show verbatim quote
    discharge filler 5 95 105 3183 93.75 90.53
  15. Number of events: 5.00 events · as reported: “discharge filler”
    Show verbatim quote
    discharge filler 5 95 105 3183 93.75 90.53