Filler product bowl malfunction
In short
It appears in fewer than 1 of every 100 lines studied.
When it appears, it takes on average about 57 % of the line's lost time. Reported by 0 of the 120 studies that could observe it (sparse evidence).
What happens
The product bowl that feeds product to the filling heads develops a mechanical or sensor fault (level sensor, valve, seal, agitator or drive) that disrupts the supply of product to the filler. This either stops the filler outright or leaves product flowing in an inconsistent, non-uniform state so that the fill delivered to each container is incorrect.
What is done about it
Apply preventive maintenance to the bowl's level sensors, seals, agitator and drive, and recalibrate the level control loop so product supply to the filling valves remains stable. Inspect and replace worn components during scheduled stops and add condition monitoring on the bowl subsystem to catch degradation before it causes a stop or a fill defect.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.4% [0.1–1.1%]
- Expected share of lost time
- 0.2% [0.0–0.7%]
- Share of lost time when present
- 57% [46–67%]
- Studies / units
- 120 / 162
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.4% [0.0–1.7%]18 studies
- Soft drinks, bottled water and juices0.4% [0.0–1.4%]44 studies
- Brewing, wine and spirits0.4% [0.0–1.7%]16 studies
- Bakery and pasta0.5% [0.0–1.8%]0 studies
- Meat, poultry and seafood0.5% [0.0–1.6%]6 studies
- Fruit and vegetable processing0.5% [0.0–1.9%]4 studies
- Grain and oilseed milling0.5% [0.0–1.8%]6 studies
- Sugar and confectionery0.5% [0.0–1.7%]3 studies
- Snacks, coffee, tea and other foods0.5% [0.0–1.8%]6 studies
- Animal feed and pet food0.5% [0.0–1.8%]4 studies
- Food manufacturing (unspecified or mixed)0.4% [0.0–1.7%]13 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceThe product bowl that feeds product to the filling heads develops a mechanical or sensor fault (level sensor, valve, seal, agitator or drive) that disrupts the supply of product to the filler. This either stops the filler outright or leaves product flowing in an inconsistent, non-uniform state so that the fill delivered to each container is incorrect.
How it looks in SCADA data
Engineering guidanceLevel or pressure alarms on the bowl precede filler stopped-state events, with the filler fault code pointing to the bowl/hopper subsystem rather than the dosing valves themselves. Fill-weight or fill-volume trend data shows drift or out-of-tolerance readings time-correlated with bowl low/high level or agitator fault flags, and upstream/downstream conveyors show starvation or blocking consistent with the filler stop.
Countermeasure
Engineering guidanceApply preventive maintenance to the bowl's level sensors, seals, agitator and drive, and recalibrate the level control loop so product supply to the filling valves remains stable. Inspect and replace worn components during scheduled stops and add condition monitoring on the bowl subsystem to catch degradation before it causes a stop or a fill defect.
4Sources
- ANALISIS TOTAL PRODUCTIVE MAINTENANCE PADA LINE 8/CARBONATED SOFT DRINK PT COCA-COLA BOTTLING INDONESIA CENTRAL JAVA (2012)Open sourceLost time: 165 min · as reported: “product bowl”
Show verbatim quote
product bowl 1 165 112 3516 100 100
- ANALISIS TOTAL PRODUCTIVE MAINTENANCE PADA LINE 8/CARBONATED SOFT DRINK PT COCA-COLA BOTTLING INDONESIA CENTRAL JAVA (2012)Open sourceNumber of events: 1.00 events · as reported: “product bowl”
Show verbatim quote
product bowl 1 165 112 3516 100 100
- Lost time: 30.0 kg · as reported: “defect product”
Show verbatim quote
The losses from defect products caused by the disruption of the production process and the reduction in the production volume amounted to LDP = 30 kg.
- Specific energy: 213 Wh/1000 Bottles · as reported: “Production”
Show verbatim quote
Production 119 4290.2 117 212.8 121 581.6