Filler start-up yield loss
In short
It appears in fewer than 1 of every 100 lines studied.
When it appears, it takes on average about 47 % of the line's lost time. Reported by 0 of the 120 studies that could observe it (sparse evidence).
What happens
During the ramp-up of the filling machine after a stop, changeover or line start, fill valves, dosing pumps and level/weight controls have not yet stabilised, so containers are under-filled, over-filled or run empty before the setpoint is reached. Product used to prime lines, displace air or flush the product-water interface is diverted to drain or scrap rather than into saleable packs.
What is done about it
Standardise and automate the start-up sequence with recipe-driven ramp profiles for valves and pumps, use in-line sensors to detect when fill parameters are within tolerance before accepting packs as good, and minimise product lost to priming or interface flushing through recirculation or smaller dedicated flush volumes.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.3% [0.0–1.0%]
- Expected share of lost time
- 0.1% [0.0–0.5%]
- Share of lost time when present
- 47% [28–65%]
- Studies / units
- 120 / 162
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.4% [0.0–1.4%]18 studies
- Soft drinks, bottled water and juices0.3% [0.0–1.1%]44 studies
- Brewing, wine and spirits0.4% [0.0–1.4%]16 studies
- Bakery and pasta0.4% [0.0–1.6%]0 studies
- Meat, poultry and seafood0.4% [0.0–1.5%]6 studies
- Fruit and vegetable processing0.4% [0.0–1.5%]4 studies
- Grain and oilseed milling0.4% [0.0–1.5%]6 studies
- Sugar and confectionery0.4% [0.0–1.6%]3 studies
- Snacks, coffee, tea and other foods0.4% [0.0–1.5%]6 studies
- Animal feed and pet food0.4% [0.0–1.5%]4 studies
- Food manufacturing (unspecified or mixed)0.4% [0.0–1.5%]13 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceDuring the ramp-up of the filling machine after a stop, changeover or line start, fill valves, dosing pumps and level/weight controls have not yet stabilised, so containers are under-filled, over-filled or run empty before the setpoint is reached. Product used to prime lines, displace air or flush the product-water interface is diverted to drain or scrap rather than into saleable packs.
How it looks in SCADA data
Engineering guidanceSCADA shows the filler in a start-up or warm-up machine state preceding the stable-run state, with fill weight/level or flow signals outside control limits during the first cycles, elevated reject or recirculation counts coincident with this state, and a gap between total product metered and good packs produced immediately after each restart.
Countermeasure
Engineering guidanceStandardise and automate the start-up sequence with recipe-driven ramp profiles for valves and pumps, use in-line sensors to detect when fill parameters are within tolerance before accepting packs as good, and minimise product lost to priming or interface flushing through recirculation or smaller dedicated flush volumes.
4Sources
- Performance Analysis of Filling Machine Using Overall Equipment Effectiveness Metric in Beverage Company (2023)Open sourceLost time: 99.0 min · as reported: “Reduced Yield”
Show verbatim quote
Reduced Yield 99 1,4 100
- Performance Analysis of Filling Machine Using Overall Equipment Effectiveness Metric in Beverage Company (2023)Open sourceShare of lost time: 1.40 % · as reported: “Reduced Yield”
Show verbatim quote
Reduced Yield 99 1,4 100