foratvise
Get Started
Equipment failure (breakdowns)

Filling valve malfunction

Equipment failure (breakdowns)AvailabilityFilling

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 58 % of the line's lost time. Reported by 2 of the 120 studies that could observe it (limited evidence).

What happens

Wear, clogging, misalignment or seal degradation in the filling valve prevents it from opening, closing or metering correctly, which stops the valve station or lets it dispense less product than the target dose. The same underlying mechanical degradation that triggers a valve fault can, before it fully fails, manifest as an underfilled container because the dosing element does not seat or actuate properly.

What is done about it

Apply a preventive maintenance and replacement schedule for valve seals, gaskets and wear components, including periodic calibration and leak/flow checks per head. Use condition monitoring on valve actuation signals and fill-weight trends to trigger maintenance before the degradation produces either a stoppage or systematic underfill.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.7% [0.2–1.8%]
Expected share of lost time
0.4% [0.1–1.0%]
Share of lost time when present
58% [47–67%]
Studies / units
120 / 162
Evidence grade
C

Grade C: 2 to 4 studies, or an interval wider than 0.35.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.8% [0.1–2.6%]18 studies
  • Soft drinks, bottled water and juices
    1.1% [0.2–3.1%]44 studies
  • Brewing, wine and spirits
    0.8% [0.1–2.6%]16 studies
  • Bakery and pasta
    0.9% [0.1–3.4%]0 studies
  • Meat, poultry and seafood
    0.8% [0.1–2.8%]6 studies
  • Fruit and vegetable processing
    0.9% [0.1–3.0%]4 studies
  • Grain and oilseed milling
    0.8% [0.1–2.9%]6 studies
  • Sugar and confectionery
    0.8% [0.1–3.0%]3 studies
  • Snacks, coffee, tea and other foods
    0.8% [0.1–2.9%]6 studies
  • Animal feed and pet food
    0.9% [0.1–3.0%]4 studies
  • Food manufacturing (unspecified or mixed)
    0.8% [0.1–3.0%]13 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

Wear, clogging, misalignment or seal degradation in the filling valve prevents it from opening, closing or metering correctly, which stops the valve station or lets it dispense less product than the target dose. The same underlying mechanical degradation that triggers a valve fault can, before it fully fails, manifest as an underfilled container because the dosing element does not seat or actuate properly.

How it looks in SCADA data

Engineering guidance

SCADA/MES shows discrete valve fault or error alarms tied to a specific head or station ID, abnormal valve open/close cycle times, and equipment-failure downtime logged against the filler. In parallel, fill-weight or level sensors and checkweighers register low-fill rejects correlated with the same valve position, sometimes without a stop being logged if the defect is caught only downstream.

Countermeasure

Engineering guidance

Apply a preventive maintenance and replacement schedule for valve seals, gaskets and wear components, including periodic calibration and leak/flow checks per head. Use condition monitoring on valve actuation signals and fill-weight trends to trigger maintenance before the degradation produces either a stoppage or systematic underfill.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Lost time: 655 min · as reported: “filling valve”
    Show verbatim quote
    filling valve 27 655 64 1835 57.14 52.19
  2. Number of events: 27.0 events · as reported: “filling valve”
    Show verbatim quote
    filling valve 27 655 64 1835 57.14 52.19
  3. Time between events: 41,694 not reported · as reported: “Filling Valve”
    Show verbatim quote
    Waktu Kerusakan Weibull MTTF 41693,58
  4. Mean event duration: 107 not reported · as reported: “Filling Valve”
    Show verbatim quote
    Waktu Perbaikan Weibull MTTR 107
  5. Number of events: 20,598 cases · as reported: “Under fill”
    Show verbatim quote
    Among these, underfill defects were the most frequent, with a total of 20,598 cases, followed by uncrowned bottles with 14,508 cases, and contamination with 8,124 cases.