Infeed screw/worm malfunction or jam
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 58 % of the line's lost time. Reported by 2 of the 120 studies that could observe it (limited evidence).
What happens
The infeed worm/screw meters and spaces containers at a fixed pitch to hand them off to the filler; mechanical wear, loose or worn timing settings, electrical/drive faults, or containers wedging between the screw flights disrupt this metered flow. When the timing drifts or a mechanical trip occurs the unit stops feeding containers, and when containers jam physically between the screw and guide rails the infeed path blocks until cleared.
What is done about it
Perform preventive maintenance and periodic inspection of the infeed screw drive, bearings, and timing mechanism, recalibrating the worm timing to the container format in use; clear jams promptly and add or tune container-presence/guide sensors to reduce misfeeds and trips.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.7% [0.2–2.0%]
- Expected share of lost time
- 0.4% [0.1–1.1%]
- Share of lost time when present
- 58% [46–68%]
- Studies / units
- 120 / 162
- Evidence grade
- C
Grade C: 2 to 4 studies, or an interval wider than 0.35.
2Probability by segment
- Dairy products0.8% [0.1–2.7%]18 studies
- Soft drinks, bottled water and juices1.2% [0.2–3.2%]44 studies
- Brewing, wine and spirits0.8% [0.1–2.7%]16 studies
- Bakery and pasta0.9% [0.1–3.4%]0 studies
- Meat, poultry and seafood0.8% [0.1–2.8%]6 studies
- Fruit and vegetable processing0.9% [0.1–3.2%]4 studies
- Grain and oilseed milling0.9% [0.1–3.1%]6 studies
- Sugar and confectionery0.9% [0.1–3.4%]3 studies
- Snacks, coffee, tea and other foods0.8% [0.1–2.9%]6 studies
- Animal feed and pet food0.9% [0.1–3.2%]4 studies
- Food manufacturing (unspecified or mixed)0.8% [0.1–2.9%]13 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceThe infeed worm/screw meters and spaces containers at a fixed pitch to hand them off to the filler; mechanical wear, loose or worn timing settings, electrical/drive faults, or containers wedging between the screw flights disrupt this metered flow. When the timing drifts or a mechanical trip occurs the unit stops feeding containers, and when containers jam physically between the screw and guide rails the infeed path blocks until cleared.
How it looks in SCADA data
Engineering guidanceSCADA/MES logs show infeed drive trip or fault alarms, screw motor stop states, and repeated short-duration downtime events tagged as jams at the infeed station, often accompanied by container-presence sensor flutter and downstream filler starvation (filler idle while waiting for containers).
Countermeasure
Engineering guidancePerform preventive maintenance and periodic inspection of the infeed screw drive, bearings, and timing mechanism, recalibrating the worm timing to the container format in use; clear jams promptly and add or tune container-presence/guide sensors to reduce misfeeds and trips.
4Sources
- Efficiency Improvement of Glass Bottle Filler Machine Using Autonomous Maintenance-A Case Study (2025)Open sourceLost time: 71.0 min · as reported: “Infeed jam”
Show verbatim quote
Infeed jam 6 8 14 7 12 13 71 4.85
- Efficiency Improvement of Glass Bottle Filler Machine Using Autonomous Maintenance-A Case Study (2025)Open sourceShare of lost time: 4.85 % · as reported: “Infeed jam”
Show verbatim quote
Infeed jam 6 8 14 7 12 13 71 4.85
- Efficiency Improvement of Glass Bottle Filler Machine Using Autonomous Maintenance-A Case Study (2025)Open sourceLost time: 16.0 min · as reported: “Infeed unit trip”
Show verbatim quote
Infeed unit trip 8 1 2 0 0 5 16 1.09
- Efficiency Improvement of Glass Bottle Filler Machine Using Autonomous Maintenance-A Case Study (2025)Open sourceShare of lost time: 1.09 % · as reported: “Infeed unit trip”
Show verbatim quote
Infeed unit trip 8 1 2 0 0 5 16 1.09
- Efficiency Improvement of Glass Bottle Filler Machine Using Autonomous Maintenance-A Case Study (2025)Open sourceLost time: 28.0 min · as reported: “Infeed worm timing setting”
Show verbatim quote
Infeed worm timing setting 4 8 0 0 0 16 28 1.91
- Efficiency Improvement of Glass Bottle Filler Machine Using Autonomous Maintenance-A Case Study (2025)Open sourceShare of lost time: 1.91 % · as reported: “Infeed worm timing setting”
Show verbatim quote
Infeed worm timing setting 4 8 0 0 0 16 28 1.91
- Efficiency Improvement of Glass Bottle Filler Machine Using Autonomous Maintenance-A Case Study (2025)Open sourceLost time: 5.00 min · as reported: “Infeed unit trip”
Show verbatim quote
14 | Infeed unit trip | 8 | 1 | 2 | 0 | 0 | 5 | 16 | 1.09
- Efficiency Improvement of Glass Bottle Filler Machine Using Autonomous Maintenance-A Case Study (2025)Open sourceLost time: 16.0 min · as reported: “Infeed worm timing setting”
Show verbatim quote
15 | Infeed worm timing setting | 4 | 8 | 0 | 0 | 0 | 16 | 28 | 1.91
- ANALISIS TOTAL PRODUCTIVE MAINTENANCE PADA LINE 8/CARBONATED SOFT DRINK PT COCA-COLA BOTTLING INDONESIA CENTRAL JAVA (2012)Open sourceLost time: 623 min · as reported: “infeed screw”
Show verbatim quote
infeed screw 13 623 93 2888 83.03 82.14
- ANALISIS TOTAL PRODUCTIVE MAINTENANCE PADA LINE 8/CARBONATED SOFT DRINK PT COCA-COLA BOTTLING INDONESIA CENTRAL JAVA (2012)Open sourceNumber of events: 13.0 events · as reported: “infeed screw”
Show verbatim quote
infeed screw 13 623 93 2888 83.03 82.14