Metal detector malfunction
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 57 % of the line's lost time. Reported by 1 of the 120 studies that could observe it (sparse evidence).
What happens
The metal detector unit on the filling line experiences an electrical, sensor or calibration fault (coil drift, false triggering, wiring or control-board failure) that stops it from reliably passing or rejecting product. This forces the line to halt while the detector is inspected, recalibrated or repaired before production can resume.
What is done about it
Implement scheduled preventive maintenance and sensitivity verification of the metal detector with certified test pieces, keep spare sensor and control boards on hand, and establish a rapid diagnostic and reset procedure so faults are cleared quickly without extended line stoppage.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.5% [0.1–1.5%]
- Expected share of lost time
- 0.3% [0.1–0.9%]
- Share of lost time when present
- 57% [45–66%]
- Studies / units
- 120 / 162
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.6% [0.1–2.1%]18 studies
- Soft drinks, bottled water and juices0.7% [0.1–2.1%]44 studies
- Brewing, wine and spirits0.6% [0.1–2.1%]16 studies
- Bakery and pasta0.7% [0.1–2.6%]0 studies
- Meat, poultry and seafood0.6% [0.1–2.2%]6 studies
- Fruit and vegetable processing0.7% [0.1–2.6%]4 studies
- Grain and oilseed milling0.6% [0.1–2.3%]6 studies
- Sugar and confectionery0.7% [0.1–2.5%]3 studies
- Snacks, coffee, tea and other foods0.6% [0.1–2.5%]6 studies
- Animal feed and pet food0.6% [0.1–2.4%]4 studies
- Food manufacturing (unspecified or mixed)0.6% [0.1–2.4%]13 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceThe metal detector unit on the filling line experiences an electrical, sensor or calibration fault (coil drift, false triggering, wiring or control-board failure) that stops it from reliably passing or rejecting product. This forces the line to halt while the detector is inspected, recalibrated or repaired before production can resume.
How it looks in SCADA data
Engineering guidanceMES/SCADA logs show a downstream stop or line-stopped state originating at the metal detector station, often with an associated fault or alarm code, repeated reject/trip events without a confirmed contaminant, or a maintenance/check activity logged against the detector asset. Upstream filling stations show blocking while the detector is offline for diagnosis.
Countermeasure
Engineering guidanceImplement scheduled preventive maintenance and sensitivity verification of the metal detector with certified test pieces, keep spare sensor and control boards on hand, and establish a rapid diagnostic and reset procedure so faults are cleared quickly without extended line stoppage.
4Sources
- Share of lost time: 9.00 % · as reported: “Falha no detector de metal”
Show verbatim quote
verificamos que apenas 9 % das paradas na enchedora estavam relacionadas com o detector de metal, sendo assim esta causa-raiz foi descartada por não apresentar significância estatística segundo o critério estabelecido pelo grupo
- Set Up Time Reduction Using Single Minute Exchange of Dies (SMED) and 5S: A Case Study (2021)Open sourceLost time: 2.00 min · as reported: “Checking Metal Detector”
Show verbatim quote
Record Counter Metal Detector 0:00:00 0:01:00 0:01:00; Verified positive sample metal detector 0:01:00 0:02:00 0:01:00