Pneumatic Component Failure (Air Hose / Solenoid Valve)

Equipment failure (breakdowns)AvailabilityFilling

In short

It appears in fewer than 1 of every 100 lines studied.

When it appears, it takes on average about 57 % of the line's lost time. Reported by 0 of the 120 studies that could observe it (sparse evidence).

What happens

The pneumatic circuit that actuates the filling valves, cylinders or nozzles loses integrity because an air hose cracks, splits, abrades or disconnects from vibration and fatigue, or because a solenoid valve sticks, wears internally, or suffers a coil/electrical fault that blocks air flow. Without reliable compressed air delivery or switching, the filling actuators cannot move correctly and the machine stops or faults.

What is done about it

Implement scheduled inspection and preventive replacement of air hoses based on condition (cracking, abrasion, fitting wear), route hoses away from pinch points and heat sources, and apply periodic functional testing, cleaning or proactive replacement of solenoid valves. Install upstream filtration, pressure regulation and monitoring to detect degradation before it causes a stop.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.4% [0.1–1.2%]
Expected share of lost time
0.2% [0.0–0.7%]
Share of lost time when present
57% [46–67%]
Studies / units
120 / 162
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.4% [0.0–1.6%]18 studies
  • Soft drinks, bottled water and juices
    0.4% [0.0–1.3%]44 studies
  • Brewing, wine and spirits
    0.4% [0.0–1.8%]16 studies
  • Bakery and pasta
    0.5% [0.0–1.9%]0 studies
  • Meat, poultry and seafood
    0.5% [0.0–1.7%]6 studies
  • Fruit and vegetable processing
    0.5% [0.0–1.9%]4 studies
  • Grain and oilseed milling
    0.5% [0.0–1.9%]6 studies
  • Sugar and confectionery
    0.5% [0.0–1.9%]3 studies
  • Snacks, coffee, tea and other foods
    0.5% [0.0–1.9%]6 studies
  • Animal feed and pet food
    0.5% [0.0–1.8%]4 studies
  • Food manufacturing (unspecified or mixed)
    0.4% [0.0–1.7%]13 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

The pneumatic circuit that actuates the filling valves, cylinders or nozzles loses integrity because an air hose cracks, splits, abrades or disconnects from vibration and fatigue, or because a solenoid valve sticks, wears internally, or suffers a coil/electrical fault that blocks air flow. Without reliable compressed air delivery or switching, the filling actuators cannot move correctly and the machine stops or faults.

How it looks in SCADA data

Engineering guidance

SCADA/MES logs show low air pressure alarms or pressure-switch trips localized to the filling station, actuator position feedback that does not match the commanded state, cylinder or valve cycle timeouts, and the filling head registering a fault or stopped state while upstream/downstream stations continue briefly before starving or blocking. Repeated short stop events with the same pneumatic fault code are typical.

Countermeasure

Engineering guidance

Implement scheduled inspection and preventive replacement of air hoses based on condition (cracking, abrasion, fitting wear), route hoses away from pinch points and heat sources, and apply periodic functional testing, cleaning or proactive replacement of solenoid valves. Install upstream filtration, pressure regulation and monitoring to detect degradation before it causes a stop.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Number of events: 2.00 events · as reported: “Solenoid Air”
    Show verbatim quote
    Solenoid Air 2
  2. Number of events: 5.00 events · as reported: “Air Hose”
    Show verbatim quote