foratvise
Get Started
Equipment failure (breakdowns)

Overheating-induced failure of sealing control components (scale, RCU, thermocouple)

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 58 % of the line's lost time. Reported by 1 of the 112 studies that could observe it (sparse evidence).

What happens

Sustained heat exposure near the filling and sealing station degrades the electronics of the weigh-bucket controller, the relay/control unit (RCU) and the thermocouple sensing cables, causing erratic signals, open circuits or loss of calibration. Because the sealing jaw temperature control depends on accurate thermocouple feedback, these faults make the heat-seal temperature unstable, producing weak or leaking seals on the packages.

What is done about it

Install heat shielding, ventilation or local cooling around the control electronics and sensor cabling near the sealing station, and specify high-temperature-rated thermocouple cables and connectors. Implement a preventive inspection and replacement schedule for thermocouples, cables and control units based on thermal exposure rather than waiting for failure.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.6% [0.1–1.6%]
Expected share of lost time
0.3% [0.1–0.9%]
Share of lost time when present
58% [46–68%]
Studies / units
112 / 155
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.7% [0.1–2.2%]14 studies
  • Soft drinks, bottled water and juices
    0.6% [0.1–1.8%]33 studies
  • Brewing, wine and spirits
    0.7% [0.1–2.3%]14 studies
  • Bakery and pasta
    0.7% [0.1–2.6%]6 studies
  • Meat, poultry and seafood
    0.7% [0.1–2.5%]6 studies
  • Fruit and vegetable processing
    0.7% [0.1–2.6%]4 studies
  • Grain and oilseed milling
    0.7% [0.1–2.4%]4 studies
  • Sugar and confectionery
    0.7% [0.1–2.7%]4 studies
  • Snacks, coffee, tea and other foods
    0.7% [0.1–2.4%]8 studies
  • Animal feed and pet food
    0.7% [0.1–2.5%]5 studies
  • Food manufacturing (unspecified or mixed)
    1.0% [0.1–3.4%]14 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

Sustained heat exposure near the filling and sealing station degrades the electronics of the weigh-bucket controller, the relay/control unit (RCU) and the thermocouple sensing cables, causing erratic signals, open circuits or loss of calibration. Because the sealing jaw temperature control depends on accurate thermocouple feedback, these faults make the heat-seal temperature unstable, producing weak or leaking seals on the packages.

How it looks in SCADA data

Engineering guidance

Recurrent fault or alarm codes on the bucket weigh controller, RCU and thermocouple input channels, with temperature readings that drift, spike or drop out intermittently rather than failing cleanly. These electrical faults cluster in time with seal-leak rejects or downstream inspection failures, and machine logs show repeated short stops for component reset or cable reseating before a longer maintenance intervention.

Countermeasure

Engineering guidance

Install heat shielding, ventilation or local cooling around the control electronics and sensor cabling near the sealing station, and specify high-temperature-rated thermocouple cables and connectors. Implement a preventive inspection and replacement schedule for thermocouples, cables and control units based on thermal exposure rather than waiting for failure.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Number of events: 4,524 occurrences · as reported: “bucket errors, RCU errors, and thermocouple cable failures caused by overheating, leading to seal leaks”
    Show verbatim quote
    These issues have contributed a total of 19,425 minutes of downtime with 4524 occurrences from October to December 2023.
  2. Lost time: 19,425 minutes · as reported: “bucket errors, RCU errors, and thermocouple cable failures caused by overheating, leading to seal leaks”
    Show verbatim quote
    These issues have contributed a total of 19,425 minutes of downtime with 4524 occurrences from October to December 2023.