foratvise
Get Started
Setup and adjustments

Machine start-up and shutdown procedure time

Setup and adjustmentsAvailabilityMixing and blending

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 56 % of the line's lost time. Reported by 1 of the 31 studies that could observe it (sparse evidence).

What happens

Before production can begin or after it ends, the mixing machine must go through a sequence of preparation, warm-up or cool-down, and controlled stop steps that are not part of actual product throughput. This includes positioning tooling, purging or priming systems, verifying settings, and bringing the equipment to a safe idle or off state, all of which hold the line out of productive operation.

What is done about it

Standardize and document start-up and shutdown checklists, pre-stage tooling and settings before the scheduled window, and automate sequential steps (purge, warm-up, parameter loading) where feasible to shorten the non-productive interval. Track these intervals separately from faults to monitor and progressively reduce their duration.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.8% [0.1–2.7%]
Expected share of lost time
0.5% [0.1–1.5%]
Share of lost time when present
56% [44–67%]
Studies / units
31 / 40
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    1.0% [0.1–3.8%]6 studies
  • Soft drinks, bottled water and juices
    1.0% [0.1–4.0%]2 studies
  • Brewing, wine and spirits
    1.0% [0.1–4.3%]0 studies
  • Bakery and pasta
    1.4% [0.1–5.5%]2 studies
  • Meat, poultry and seafood
    1.0% [0.1–4.3%]1 study
  • Fruit and vegetable processing
    1.0% [0.1–3.9%]2 studies
  • Grain and oilseed milling
    1.0% [0.1–4.2%]0 studies
  • Sugar and confectionery
    1.0% [0.1–3.9%]3 studies
  • Snacks, coffee, tea and other foods
    1.0% [0.1–3.9%]3 studies
  • Animal feed and pet food
    1.0% [0.1–3.8%]5 studies
  • Food manufacturing (unspecified or mixed)
    0.9% [0.1–3.5%]7 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

Before production can begin or after it ends, the mixing machine must go through a sequence of preparation, warm-up or cool-down, and controlled stop steps that are not part of actual product throughput. This includes positioning tooling, purging or priming systems, verifying settings, and bringing the equipment to a safe idle or off state, all of which hold the line out of productive operation.

How it looks in SCADA data

Engineering guidance

MES/SCADA logs show a distinct machine state (preparation, start-up or shutdown) bounded by operator or recipe triggers, with no output counter increment during this interval. Repeated occurrences align with shift boundaries, order changes or planned stop events rather than random fault alarms.

Countermeasure

Engineering guidance

Standardize and document start-up and shutdown checklists, pre-stage tooling and settings before the scheduled window, and automate sequential steps (purge, warm-up, parameter loading) where feasible to shorten the non-productive interval. Track these intervals separately from faults to monitor and progressively reduce their duration.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Mean event duration: 0.130 min · as reported: “Stop machine”
    Show verbatim quote
    Stop machine Operator 1 DRY Operator 1 DRY Internal Internal 0.13 0.17
  2. Mean event duration: 2.80 min · as reported: “Machine prep for operation”
    Show verbatim quote
    Machine prep for operation Operator 2 DRY Operator 2 DRY Internal Internal 2.80 2.80
  3. Mean event duration: 0.930 min · as reported: “Start the machine”
    Show verbatim quote
    Start the machine Operator 1 DRY Operator 1 DRY Internal Internal 0.93 0.93
  4. Mean event duration: 0.170 min · as reported: “Stop machine”
    Show verbatim quote
    Stop machine Operator 1 DRY Operator 1 DRY Internal Internal 0.13 0.17
  5. Mean event duration: 2.80 min · as reported: “Machine prep for operation”
    Show verbatim quote
    Machine prep for operation Operator 2 DRY Operator 2 DRY Internal Internal 2.80 2.80
  6. Mean event duration: 0.930 min · as reported: “Start the machine”
    Show verbatim quote
    Start the machine Operator 1 DRY Operator 1 DRY Internal Internal 0.93 0.93