foratvise
Get Started
Idling and minor stops (micro-stops)

Minor stoppages on sterilizer

Idling and minor stops (micro-stops)PerformanceSterilization (retort, UHT)

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 53 % of the line's lost time. Reported by 1 of the 34 studies that could observe it (sparse evidence).

What happens

Short interruptions occur on the sterilizer (retort or UHT line) when containers or carriers jam at infeed/outfeed, sensors are momentarily blocked, or chains and conveyors hang up during loading and unloading of the sterilization cycle. These stoppages are cleared by the operator on the spot without any maintenance intervention and do not involve a mechanical or electrical failure.

What is done about it

Standard countermeasures include improving container/carrier guiding and alignment at infeed and outfeed, adjusting sensor sensitivity and positioning to avoid false blocking, and reviewing accumulation buffers to reduce jam frequency. Operator training on fast, safe clearing procedures and periodic review of minor-stop logs to target recurring trouble spots are also typical.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.9% [0.1–2.9%]
Expected share of lost time
0.5% [0.1–1.5%]
Share of lost time when present
53% [40–65%]
Studies / units
34 / 37
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    1.1% [0.1–4.4%]5 studies
  • Soft drinks, bottled water and juices
    1.1% [0.1–4.2%]2 studies
  • Brewing, wine and spirits
    1.1% [0.1–4.5%]1 study
  • Bakery and pasta
    1.1% [0.1–4.5%]0 studies
  • Meat, poultry and seafood
    1.1% [0.1–4.4%]1 study
  • Fruit and vegetable processing
    1.1% [0.1–4.5%]2 studies
  • Grain and oilseed milling
    1.6% [0.1–6.4%]6 studies
  • Sugar and confectionery
    1.1% [0.1–4.3%]3 studies
  • Snacks, coffee, tea and other foods
    1.1% [0.1–4.4%]3 studies
  • Animal feed and pet food
    1.1% [0.1–4.6%]4 studies
  • Food manufacturing (unspecified or mixed)
    1.0% [0.1–4.1%]7 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

Short interruptions occur on the sterilizer (retort or UHT line) when containers or carriers jam at infeed/outfeed, sensors are momentarily blocked, or chains and conveyors hang up during loading and unloading of the sterilization cycle. These stoppages are cleared by the operator on the spot without any maintenance intervention and do not involve a mechanical or electrical failure.

How it looks in SCADA data

Engineering guidance

MES/SCADA logs show a high number of brief machine-state transitions to stopped or fault-reset states with very short durations, often clustered around infeed/outfeed sensors or carrier/chain position signals, interspersed with normal running states. Upstream or downstream equipment may show short starvation or blocking periods correlated with these events, but no work order or maintenance alarm is generated.

Countermeasure

Engineering guidance

Standard countermeasures include improving container/carrier guiding and alignment at infeed and outfeed, adjusting sensor sensitivity and positioning to avoid false blocking, and reviewing accumulation buffers to reduce jam frequency. Operator training on fast, safe clearing procedures and periodic review of minor-stop logs to target recurring trouble spots are also typical.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Share of lost time: 25.2 % · as reported: “Idling minor Stoppages”
    Show verbatim quote
    Faktor terbesar yang mempengaruhi efektifitas mesin Sterilizer dan menjadi prioritas untuk dieleminasi adalah faktor Equipment Failures sebesar 61,54% dan faktor Idling minor Stoppages sebesar 25,15%.
  2. Share of lost time: 0 % · as reported: “Idling And Minor Stoppages”
    Show verbatim quote
    Idling And Minor Stoppages by 0% and Rework Loss by 0%