Waiting for supervisor confirmation/authorization
In short
It appears in fewer than 1 of every 100 lines studied.
When it appears, it takes on average about 56 % of the line's lost time. Reported by 1 of the 127 studies that could observe it (sparse evidence).
What happens
During a changeover or setup step the operator must obtain explicit approval from a supervisor or quality responsible before the line can resume or proceed to the next step, and production remains paused while this organizational authorization is sought and granted. The delay is not caused by a technical fault but by the need for a human sign-off embedded in the changeover procedure.
What is done about it
Define clear escalation and response-time rules for supervisor sign-offs, use remote or mobile approval tools so confirmation can be given without the supervisor being physically present, and delegate low-risk confirmations to trained operators to reduce dependence on a single authorizing role.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.5% [0.1–1.4%]
- Expected share of lost time
- 0.3% [0.1–0.8%]
- Share of lost time when present
- 56% [44–67%]
- Studies / units
- 127 / 161
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.6% [0.1–2.1%]13 studies
- Soft drinks, bottled water and juices0.5% [0.1–1.7%]26 studies
- Brewing, wine and spirits0.6% [0.1–2.0%]11 studies
- Bakery and pasta0.5% [0.1–1.9%]24 studies
- Meat, poultry and seafood0.6% [0.1–2.1%]9 studies
- Fruit and vegetable processing0.6% [0.1–2.2%]7 studies
- Grain and oilseed milling0.6% [0.1–2.1%]6 studies
- Sugar and confectionery0.6% [0.1–2.0%]9 studies
- Snacks, coffee, tea and other foods0.6% [0.1–1.9%]5 studies
- Animal feed and pet food0.8% [0.1–3.0%]7 studies
- Food manufacturing (unspecified or mixed)0.6% [0.1–2.2%]10 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceDuring a changeover or setup step the operator must obtain explicit approval from a supervisor or quality responsible before the line can resume or proceed to the next step, and production remains paused while this organizational authorization is sought and granted. The delay is not caused by a technical fault but by the need for a human sign-off embedded in the changeover procedure.
How it looks in SCADA data
Engineering guidanceMES/SCADA shows the line or station in a held or paused state within a changeover event, with no fault alarm active, and the stop ends only when a confirmation or release event is logged, often tied to an operator or supervisor login action. The waiting interval appears as idle time nested inside the changeover duration rather than as a discrete machine fault code.
Countermeasure
Engineering guidanceDefine clear escalation and response-time rules for supervisor sign-offs, use remote or mobile approval tools so confirmation can be given without the supervisor being physically present, and delegate low-risk confirmations to trained operators to reduce dependence on a single authorizing role.
4Sources
- Production Management Model Based on Lean Manufacturing Tools and SLP to Increase Productivity in a Meatball (BARF) Plant (2026)Open sourceMean event duration: 3.00 min · as reported: “Wait for supervisor confirmation”
Show verbatim quote
Wait for supervisor confirmation 3.00 Internal Eliminated
- Production Management Model Based on Lean Manufacturing Tools and SLP to Increase Productivity in a Meatball (BARF) Plant (2026)Open sourceLost time: 3.00 min · as reported: “Wait for supervisor confirmation”
Show verbatim quote
Wait for supervisor confirmation 3.00