Equipment failure (breakdowns)

Ingredient weighing station fault or delay

Equipment failure (breakdowns)AvailabilityWhole line or unspecified equipment

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 58 % of the line's lost time. Reported by 3 of the 127 studies that could observe it (limited evidence).

What happens

The weighing station used to dose raw materials, premixes or microingredients (such as lysine) stops producing valid output because the scale, load cell, feeder or control interface malfunctions, or because operators must stop the process to search for and bring the correct material to the weighing point. Both failure modes interrupt the sequential dosing step that feeds the mixing or batching stage downstream.

What is done about it

Implement preventive calibration and maintenance of scales, load cells and feeders, and use automated diagnostics to flag drift or sensor faults before they cause stoppages. Organize material staging with kanban or pre-positioned bins near the weighing point and barcode or RFID verification to eliminate search and retrieval time.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.8% [0.2–2.0%]
Expected share of lost time
0.4% [0.1–1.1%]
Share of lost time when present
58% [47–68%]
Studies / units
127 / 161
Evidence grade
C

Grade C: 2 to 4 studies, or an interval wider than 0.35.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.9% [0.1–3.1%]13 studies
  • Soft drinks, bottled water and juices
    0.8% [0.1–2.5%]26 studies
  • Brewing, wine and spirits
    0.9% [0.1–3.1%]11 studies
  • Bakery and pasta
    1.1% [0.2–3.7%]24 studies
  • Meat, poultry and seafood
    0.9% [0.1–3.2%]9 studies
  • Fruit and vegetable processing
    0.9% [0.1–3.4%]7 studies
  • Grain and oilseed milling
    0.9% [0.1–3.2%]6 studies
  • Sugar and confectionery
    0.9% [0.1–3.0%]9 studies
  • Snacks, coffee, tea and other foods
    0.9% [0.1–3.1%]5 studies
  • Animal feed and pet food
    1.3% [0.2–4.3%]7 studies
  • Food manufacturing (unspecified or mixed)
    0.9% [0.1–3.1%]10 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

The weighing station used to dose raw materials, premixes or microingredients (such as lysine) stops producing valid output because the scale, load cell, feeder or control interface malfunctions, or because operators must stop the process to search for and bring the correct material to the weighing point. Both failure modes interrupt the sequential dosing step that feeds the mixing or batching stage downstream.

How it looks in SCADA data

Engineering guidance

MES/SCADA shows the weighing station in fault or idle state with no stable weight reading or dosing confirmation, batch sequence held at the weighing step, and operator acknowledgement events tied to scale alarms or manual material-retrieval entries. Downstream mixing or blending equipment shows starvation (waiting-for-material) states correlated with these stoppages.

Countermeasure

Engineering guidance

Implement preventive calibration and maintenance of scales, load cells and feeders, and use automated diagnostics to flag drift or sensor faults before they cause stoppages. Organize material staging with kanban or pre-positioned bins near the weighing point and barcode or RFID verification to eliminate search and retrieval time.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Lost time: 0.837 Kg.h-1 · as reported: “Weighing (microingredients)”
    Show verbatim quote
    6Weighing 32.50 0.026 ± 0.009 0.837 ± 0.293 Kg 10.45
  2. Lost time: 0.161 Kg.h-1 · as reported: “Weighing (lysine)”
    Show verbatim quote
    7Weighing 10.20 0.016 ± 0.004 0.161 ± 0.041 Kg 2,01
  3. Lost time: 0.194 Kg.h-1 · as reported: “Weighing (premixes)”
    Show verbatim quote
    8Weighing 20.30 0.010 ± 0.002 0.194 ± 0.041 Kg 2.42
  4. Mean event duration: 23.5 min · as reported: “Weighing”
    Show verbatim quote
    Weighing 23.49 21.62 8%
  5. Mean event duration: 21.6 min · as reported: “Weighing”
    Show verbatim quote
    Weighing 23.49 21.62 8%
  6. Lost time: 23.5 min · as reported: “Weighing (search and material location time)”
    Show verbatim quote
    Weighing | 23.49