Evaporation
Concentration of whole milk in a falling-film evaporator
In short
Evaporation can use at most 87 of every 100 planned hours. The rest goes to limits no plant can avoid.
- 87usable at most
- 13are a physical limit
The three limits that set it
Running time: up to 95 %
The rest are stops imposed by physics or by regulation: cleaning, changeovers, defrosting.
Speed: up to 93 %
How close to its maximum speed it can run without damaging the product or the equipment.
Good product: up to 98 %
Some product falls outside specification even with the process well under control.
Technical detail
Uncertainty intervals, physical models per station and sources, for anyone who wants to check each figure.
1Scenario
Pasteurized whole milk is concentrated under vacuum in a falling-film evaporator: the milk runs as a thin film down the inside of vertical tubes heated by condensing vapour, part of its water boils off, and the concentrate leaves at the solids content required by the spray dryer. The heating vapour may be live steam (single or multiple effects), vapour recompressed by a steam-driven thermocompressor (TVR) or vapour recompressed by an electrically driven fan or compressor (MVR). Energy results are given per kg of water removed.
2Results
- Water removed per kg of concentrate3.21 [3.23–4.03] kg/kg
- Water removed per kg of milk fed0.763 [0.764–0.801] kg/kg
- Water activity of the final concentrate (ideal solution of the dissolved solutes)0.967 [0.949–0.968]
- Boiling-point elevation of the final concentrate0.731 [0.687–1.153] K
- TheoreticalThermodynamic minimum: reversible work of separation per kg of water removed1.46 [1.34–1.80] kJ/kg
- Carnot-type bound of mechanical vapour recompression for the declared film temperature difference, per kg of water22.6 [16.1–29.6] kJ/kg
- Isentropic compression work of mechanical vapour recompression (CoolProp), per kg of water23.2 [16.4–30.5] kJ/kg
- Best available techniqueEnergy of a mechanical vapour recompression evaporator (best available technique), per kg of water36.0 kJ/kg
- Best documentedDocumented total energy of a single-stage MVR evaporator, per kg of water54.0 kJ/kg
- TypicalDocumented total energy of TVR evaporators with the common number of stages (3 to 5), per kg of water396 [308–499] kJ/kg
- Ideal heat of a single effect (latent heat, feed at the boiling point), per kg of water2,356 [2,332–2,379] kJ/kg
- Ideal heat of an N-effect evaporator (steam economy N), per kg of water336.6 [333.1–339.8] kJ/kg
- TheoreticalIdeal steam per kg of water, single effect1.0031 [1.0021–1.0041] kg/kg
- TheoreticalIdeal steam per kg of water, double effect0.5035 [0.5026–0.5047] kg/kg
- TheoreticalIdeal steam per kg of water, triple effect0.3370 [0.3361–0.3382] kg/kg
- Ideal (isentropic) thermocompressor entrainment: kg of vapour recompressed per kg of motive steam20.7 [15.1–28.6] kg/kg
- Ideal motive steam per kg of water, single effect with thermal vapour recompression0.0462 [0.0338–0.0625] kg/kg
- Temperature lift implied by the BAT energy if it were ideal Carnot work5.09 [4.90–5.29] K
- TheoreticalMaximum evaporation rate per unit of heating surface, clean film (U dT / h_fg)9.17 [4.03–16.03] kg/m²/h
- Mean evaporation rate per unit of surface over a fouling-limited run8.55 [3.81–14.71] kg/m²/h
- Run length until fouling reduces the duty to the declared floor (typical practice)21.4 [4.5–109.1] h
- TheoreticalRun length that maximises A x P x Q (capped by the legal limit)7.37 [3.73–16.30] h
- TheoreticalMaximum performance factor: mean over clean rate during a run at constant temperature difference0.933 [0.864–0.968]
- TheoreticalMaximum availability (minimum cleaning after each optimal run)0.952 [0.907–0.978]
- TypicalAvailability with the declared duty floor and a typical cleaning programme0.915 [0.659–0.963]
- Share of product lost in the water-product mixing at start-up and shut-down0.0170 [0.0054–0.0462]
- TheoreticalMaximum solids yield0.983 [0.954–0.995]
- Share of concentrate outside the solids tolerance band6.33 × 10⁻⁵ [3.23 × 10⁻¹⁰–4.17 × 10⁻²]
- TheoreticalMaximum OEE quality factor (solids control and start-up losses)0.983 [0.933–0.993]
- TheoreticalPhysics-bounded OEE0.873 [0.748–0.932]
3Ceilings per dimension
- Theoretical
- Best available technique
- Best documented
- Typical
- TheoreticalDOE bandwidth study, concentration, thermodynamic minimum (set to zero for lack of chemical conversion; the separation work is not counted) · Benchmark0 kJ/kg
- TheoreticalThermodynamic minimum: reversible work of separation per kg of water removed1.46 [1.34–1.80] kJ/kg
- Best available techniqueEnergy of a mechanical vapour recompression evaporator (best available technique), per kg of water36.0 kJ/kg
- Best documentedDocumented total energy of a single-stage MVR evaporator, per kg of water54.0 kJ/kg
- Best documentedTotal energy of a 7-stage TVR evaporator (dairy industry comparison table) · Benchmark216 kJ/kg
- TypicalDocumented total energy of TVR evaporators with the common number of stages (3 to 5), per kg of water396 [308–499] kJ/kg
- TypicalTotal energy of a 3-stage TVR evaporator (dairy industry comparison table) · Benchmark504 kJ/kg
- TheoreticalIdeal steam per kg of water, single effect1.0031 [1.0021–1.0041] kg/kg
- TheoreticalIdeal steam per kg of water, double effect0.5035 [0.5026–0.5047] kg/kg
- TheoreticalIdeal steam per kg of water, triple effect0.3370 [0.3361–0.3382] kg/kg
- TheoreticalMaximum evaporation rate per unit of heating surface, clean film (U dT / h_fg)9.17 [4.03–16.03] kg/m²/h
- TheoreticalRun length that maximises A x P x Q (capped by the legal limit)7.37 [3.73–16.30] h
- TheoreticalMaximum performance factor: mean over clean rate during a run at constant temperature difference0.933 [0.864–0.968]
- TheoreticalMaximum availability (minimum cleaning after each optimal run)0.952 [0.907–0.978]
- TypicalAvailability with the declared duty floor and a typical cleaning programme0.915 [0.659–0.963]
- TheoreticalMaximum solids yield0.983 [0.954–0.995]
- TheoreticalMaximum OEE quality factor (solids control and start-up losses)0.983 [0.933–0.993]
- TheoreticalPhysics-bounded OEE0.873 [0.748–0.932]
4Loss cascade
- TheoreticalBest available techniqueEnergy per unit of product1.46 [1.34–1.80] kJ/kg → 36.0 kJ/kg (gap 34.5 kJ/kg)
The theoretical minimum is the reversible work of separating water from the dissolved milk solutes. Milk is a dilute solution (water activity above 0.99, falling to about 0.97 at 50 % solids), so this work is only a few kJ per kg of water. Any evaporator spends far more for three physical reasons. First, a temperature difference across the film is needed to drive heat through the tube wall in finite area; with mechanical vapour recompression this lift is paid as compressor work, and the Carnot-type bound for the declared difference already exceeds the separation work more than ten times. Second, the boiling-point elevation must be overcome on top of it (it is the separation work itself, seen through Clausius-Clapeyron). Third, a real compressor is not isentropic and its motor is not loss-free, and fans, pumps, vacuum and the steam-heated finisher add consumption. The best available technique (MVR, about 10 kWh per tonne of water) sits close to these bounds.
- Best available techniqueBest documentedEnergy per unit of product36.0 kJ/kg → 54.0 kJ/kg (gap 18.0 kJ/kg)
The comparison table of the BAT reference document gives 15 kWh per tonne for a single-stage MVR evaporator, against the 10 kWh per tonne reported for MVR in the technique description: the spread reflects compressor and fan efficiency, the temperature lift chosen at design (smaller lift needs more heating surface) and the auxiliaries counted.
- Best documentedTypicalEnergy per unit of product54.0 kJ/kg → 396 [308–499] kJ/kg (gap 342 kJ/kg)
Most installed evaporators are steam-driven multi-effect trains with thermal vapour recompression of three to five stages. Each kilogram of live steam is reused once per effect plus the vapour entrained by the thermocompressor, but the latent heat of the vapour from the last effect is rejected to cooling water, and the thermocompressor is far from isentropic. This is why they need roughly six to fourteen times the final energy of an MVR evaporator; the ideal-economy outputs (heat of a single and of an N-effect evaporator) show how far even a perfect steam-driven train stays above MVR, because it delivers heat rather than work.
- TheoreticalBest documentedsteam_single_effect
An ideal single effect with the feed already at its boiling point needs a little more than one kilogram of steam per kilogram of water, because the latent heat of the condensing steam at the higher temperature is smaller than that of the water boiling off. Documented single-stage evaporators need 1.1 to 1.4: the difference is the sensible heating of feed that enters below its boiling point, heat losses, venting of non-condensable gases and condensate sub-cooling.
5Physics-bounded OEE
- Loading time (ideal)1.000
- Availabilityfactor 0.952 [0.907–0.978]0.952 (−0.048)
- Performancefactor 0.933 [0.864–0.968]0.888 (−0.064)
- Qualityfactor 0.983 [0.933–0.993]0.873 (−0.015)
- Physics-bounded OEE0.873 [0.748–0.932]
6Full derivation
Scope. Pasteurized whole milk is concentrated under vacuum in a falling-film evaporator: it runs as a thin film down the inside of vertical tubes heated by condensing vapour, part of its water boils off, and the concentrate leaves at the solids content required by the spray dryer. The heating vapour may be live steam (one or several effects), vapour recompressed by a steam-driven thermocompressor (thermal vapour recompression, TVR) or vapour recompressed by an electric fan or compressor (mechanical vapour recompression, MVR). Energy results are expressed per kilogram of water removed. Symbols and their values, units, uncertainty distributions and sources are listed in the parameter table generated from config/physics/evaporation.yaml; numbers quoted in this text are the point values of that table.
1. Mass balance — maximum yield
Evaporation removes water and conserves solids. With the total solids of the milk fed (1 minus its water content, 88.13 % in the USDA record of whole milk) and the total solids of the concentrate (50 %, the lower end of the 50–60 % dry matter reported in the BAT reference document), the solids balance gives
where and are the masses of feed and concentrate.
Yield. No solids leave with the vapour in the ideal operation, so the steady-state solids yield is 1. Solids are lost in transients: at start-up the evaporator is full of water that the milk displaces, and at shut-down water pushes the last concentrate out. Each transition creates a water–product mixed zone that is a fraction of the hold-up volume; with a mean residence time of the product in the evaporator (hold-up over flow) and a run length ,
0.983 at the point values ( = 5 min, = 0.75, = 7.4 h from Section 3). Entrainment of droplets into the vapour, leaks and rinsing losses depend on the installed technology.
2. Energy balance — minimum energy per kilogram of water
2.1 Thermodynamic minimum: reversible work of separation
The dissolved milk solutes (mainly lactose and the soluble salts) lower the chemical potential of the water. Separating a small mass of water reversibly at the dead-state temperature and delivering it as pure liquid water requires , where is the molar gas constant, the molar mass of water and the water activity. For an ideal (Raoult) solution of osmoles of dissolved solutes in a mass of water ,
Per kilogram of milk, counts the lactose (5.05 % in the USDA record, molar mass 342.30 g/mol) and the soluble monovalent cations potassium and sodium (132 and 43 mg per 100 g), plus a declared share of osmotically active counter-ions (between 0 and 1 per cation); casein micelles, fat and colloidal calcium phosphate do not lower the water activity. With this is 0.257 osmol per kg of water, and = 0.9954 for milk and 0.967 for the 50 % concentrate. Integrating from the water content of the milk to that left in the concentrate (both per kg of milk):
a closed form checked against numerical quadrature in the tests. The result is 1.46 kJ per kg of water: milk is a dilute solution, so separating its water is almost free. A real concentrate is somewhat less ideal (its activity is lower), which would raise the work slightly; the ideal value is therefore a lower bound, as a theoretical ceiling must be. The DOE bandwidth study sets the thermodynamic minimum of this step to zero because it counts only chemical conversions; the same study computes for sugar concentration, which is the method used here.
2.2 Boiling-point elevation
The concentrate boils at the temperature at which the vapour pressure over the solution, , equals the pressure of the vapour space, , where is the saturation temperature of the vapour (set by the vacuum). The boiling-point elevation is
computed exactly with the IAPWS-95 saturation curve (CoolProp): 0.73 K for the final concentrate at = 60 °C. Through Clausius–Clapeyron, , which links it directly to the separation work (checked in the tests).
2.3 Steam-driven evaporation: single effect and N effects
A single effect with the feed at its boiling point needs the latent heat of the water boiled off, 2 356 kJ per kg at 60.7 °C. Steam condensing at the higher temperature , where is the temperature difference across the film, releases a slightly smaller latent heat, so the ideal steam consumption is
for effects in series, each reusing the vapour of the previous one as heating medium (ideal economy ): 1.003, 0.504 and 0.337 kg of steam per kg of water for one, two and three effects. The documented requirements are 1.1–1.4, 0.6–0.7 and 0.4; the gap is the sensible heating of feed below its boiling point, heat losses, venting and condensate sub-cooling. With the largest number of effects reported (seven), the ideal heat is = 337 kJ per kg of water.
Thermal vapour recompression. In a thermocompressor, motive steam at pressure expands and entrains vapour from the evaporator, compressing it to the pressure of the heating side. In the ideal (isentropic) limit, the work released by expanding the motive steam from to the heating pressure, , equals the work of compressing the entrained vapour from to . The entrainment ratio is the ratio of these two works, 20.7 kg of vapour per kg of motive steam at 8 bar, and the ideal motive-steam consumption of a single TVR effect is 0.046 kg per kg of water. Real thermocompressors entrain far less vapour, because the mixing of a supersonic jet with slow vapour is highly irreversible; this is why TVR evaporators, even with several stages, stay well above MVR.
2.4 Mechanical vapour recompression: Carnot-type bound and isentropic work
MVR uses the evaporator as a heat pump: vapour produced at the saturation temperature is compressed until it condenses at on the other side of the tube wall, where it delivers the heat that boils the next kilogram of water. The minimum work of a heat pump that takes heat at and delivers at is the Carnot work
averaged here over the concentration path (the BPE grows as the solids increase). With the Carnot work tends to the separation work of Section 2.1, because the BPE is the water activity seen through Clausius–Clapeyron (checked in the tests): the only irreducible cost is the separation, and everything else is the price of finite heat-transfer area. For = 3 K the bound is 22.6 kJ per kg. The isentropic compression work of the vapour between the two saturation pressures, with the IAPWS-95 heat capacities and of the vapour (within 1.5 % of the full real-gas calculation of CoolProp), is 23.2 kJ per kg; it exceeds the Carnot bound because compression from saturated vapour produces superheat that is degraded on condensation.
If the reported MVR consumption (10 kWh per tonne, 36 kJ per kg) were ideal Carnot work, the lift would be = 5.1 K; the declared film temperature differences (2–4 K) plus the BPE stay below it, so the scenario is consistent with the documented value.
2.5 The energy ceilings
Final energy per kilogram of water removed, as in the comparison table of the BAT reference document: theoretical (separation work) 1.46; best available technique (MVR evaporator, "approximately 10 kWh/t") 36; documented (single-stage MVR, 0.015 kWh/kg) 54; typical (TVR with three to five stages, the most common configurations, 0.084–0.140 kWh/kg) 396 kJ per kg. The DOE intensities for concentration of evaporated milk and powdered milk (172 Btu/lb current typical, 138 state of the art) are expressed per pound of a mix of products, not per kilogram of water, and are reported with compare: false. The statement in the BAT reference document that about 600 kWh are required to evaporate one tonne of water (2 160 kJ per kg) is of the same magnitude as, and about 8 % below, the ideal single-effect heat of Section 2.3.
3. Rate-limiting step — evaporation rate and run length
Film heat transfer. The rate at which a square metre of heating surface evaporates water is limited by the heat flux across the condensing film, the tube wall and the boiling milk film:
where is the overall heat-transfer coefficient of the clean surface. With = 2 000 W/(m² K) and = 3 K this is 9.2 kg per m² per hour. The small that saves compressor work (Section 2.4) is paid with heating surface: area and energy trade against each other.
Fouling-limited run length. Milk proteins denature on the hot surface and minerals precipitate, adding a fouling resistance that grows during the run. With a linear growth rate ,
where is the time until the duty falls to the declared fraction of the clean value, a common stopping rule (21.4 h at the point values; it defines the typical availability of Section 5). At constant the mean rate over a run of length , relative to the clean rate, is
the unavoidable performance loss of a fouling surface. A plant that raises during the run keeps the rate instead and pays in energy.
Optimal run length. A longer run raises the availability (fewer cleanings) and spreads the start-up and shut-down losses over more product, but lowers the mean rate. The bound uses the run length that maximises
found on a fine geometric grid for every Monte Carlo draw and capped by the 44 h legal limit of a continuous evaporator run. At the point values the optimum is = 7.4 h, with = 0.933; the legal limit binds only when fouling is slow.
4. Process capability — quality ceiling
The dryer accepts concentrate within a tolerance band around the solids target. With the solids under control distributed as , the share outside the band, which is recirculated, is
where is the standard normal distribution function. The OEE quality factor includes the start-up and shut-down losses of Section 1: = 0.983 at the optimal run length.
5. Unavoidable stops — maximum availability
Each run ends with cleaning-in-place. Its minimum duration is taken through a parameter link from the cleaning model (output cip_time_min: the physical minimum of the kinetic and displacement phases plus declared hold times). That model is valid for recirculated pipe and plate circuits; the falling-film tubes are pipes, but the distribution of the liquid over the tube plate and the vapour side of the calandria are outside its validity, so the linked duration is a lower bound for the evaporator. With the optimal run length,
The typical availability uses the declared duty floor and a typical cleaning programme of 1.5–3 h: = 0.915.
6. Physics-bounded OEE
Scope of the bound. The theoretical label of means physics-bounded under the declared scenario: the ceiling follows from the physics of the operation for the declared product, equipment and schedule, and it is a bound only conditional on those declarations. It follows the common definition of all models: counts only stops required by regulation or forced by a physical mechanism, at their physical minimum duration, plus the start-up they force; is the ratio of the physics-limited ideal cycle to the cycle of the capable process; is the share of conforming units, and mass losses of conforming product are reported only as yield.
at the point values; the Monte Carlo interval over all declared uncertainties is in the output table. Unlike the pasteurizer, the evaporator has a physical performance loss: fouling lowers the rate continuously between cleanings.
7. Assumptions and validity
See the assumption and validity lists generated from the configuration file. The most important are: ideal solution of the dissolved solutes; energy compared as final energy per kilogram of water; linear fouling at constant temperature difference. The most influential inputs (sensitivity table) are the film temperature difference for the MVR bounds, the fouling rate and clean heat-transfer coefficient for run length, performance and availability, and the concentrate solids for the separation work.
References
- European Commission, Joint Research Centre. Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries, 2019.
- U.S. Department of Energy. Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Food and Beverage Manufacturing, 2017.
- U.S. Food and Drug Administration. Grade "A" Pasteurized Milk Ordinance, 2023 Revision.
- U.S. Department of Agriculture, Agricultural Research Service. USDA National Nutrient Database for Standard Reference, Release 28, food group 01 report, 2015.
- Wagner, W., Pruß, A. (2002). The IAPWS formulation 1995 for the thermodynamic properties of ordinary water substance for general and scientific use. Journal of Physical and Chemical Reference Data, 31, 387–535. doi:10.1063/1.1461829
- Bell, I. H., Wronski, J., Quoilin, S., Lemort, V. (2014). Pure and pseudo-pure fluid thermophysical property evaluation and the open-source thermophysical property library CoolProp. Industrial & Engineering Chemistry Research, 53, 2498–2508. doi:10.1021/ie4033999
7Parameters and provenance
- 0.8813
Water content of whole milk (mass fraction)
Property · Fixed
Verified quoteShow verbatim quote
88.13 61 254 3.15 3.25 0.67 4.80USDA National Nutrient Database for Standard Reference, Release 28 (2015): Food Group 01, Dairy and Egg Products (nutrient report) (opens in a new tab). U.S. Department of Agriculture, Agricultural Research Service, Nutrient Data Laboratory, 2015. p. 632. USDA SR28, food group 01 report (sr28fg01.pdf)
- 0.5
Total solids of the concentrate leaving the evaporator (mass fraction)
Technology · Uniform 0.5 to 0.6
Verified quoteShow verbatim quote
After the milk has been thickened from 11 % to 50–60 % dry matter in an evaporatorBest Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 411. EUR 29978 EN; JRC118627; doi:10.2760/243911
- 0.0505
Lactose content of whole milk (mass fraction)
Property · Fixed
Verified quoteShow verbatim quote
4.80 0.0 5.05 0.00 0.00 0.00 5.05 0.00 0.00USDA National Nutrient Database for Standard Reference, Release 28 (2015): Food Group 01, Dairy and Egg Products (nutrient report) (opens in a new tab). U.S. Department of Agriculture, Agricultural Research Service, Nutrient Data Laboratory, 2015. p. 632. USDA SR28, food group 01 report (sr28fg01.pdf)
- 132 mg/hg
Potassium content of whole milk
Property · Fixed
Verified quoteShow verbatim quote
113 0.03 10 84 132 43 0.37USDA National Nutrient Database for Standard Reference, Release 28 (2015): Food Group 01, Dairy and Egg Products (nutrient report) (opens in a new tab). U.S. Department of Agriculture, Agricultural Research Service, Nutrient Data Laboratory, 2015. p. 632. USDA SR28, food group 01 report (sr28fg01.pdf)
- 43 mg/hg
Sodium content of whole milk
Property · Fixed
Verified quoteShow verbatim quote
113 0.03 10 84 132 43 0.37USDA National Nutrient Database for Standard Reference, Release 28 (2015): Food Group 01, Dairy and Egg Products (nutrient report) (opens in a new tab). U.S. Department of Agriculture, Agricultural Research Service, Nutrient Data Laboratory, 2015. p. 632. USDA SR28, food group 01 report (sr28fg01.pdf)
- 342.3 g/mol
Molar mass of lactose (C12H22O11)
Property · Fixed
Computed12 x 12.011 + 22 x 1.008 + 11 x 15.999 = 342.30 g/mol (IUPAC conventional atomic weights).
- 39.098 g/mol
Molar mass of potassium
Property · Fixed
ComputedIUPAC standard atomic weight of potassium.
- 22.99 g/mol
Molar mass of sodium
Property · Fixed
ComputedIUPAC standard atomic weight of sodium.
- 0.5
Osmotically active anions per soluble monovalent cation (0: cations only; 1: one monovalent counter-ion each)
Scenario · Uniform 0 to 1
Declared assumptionDeclared assumption bracketing the contribution of the counter-ions (chloride, citrate, phosphate) to the ideal-solution water activity; no open source for the osmolality of milk serum was verified. Calcium, magnesium and phosphate bound to the casein micelles are not counted. Replace with a cryoscopic measurement of the plant's milk (osmolality = freezing-point depression / 1.86 K kg/mol).
- 25 °C
Dead-state (ambient) temperature for the reversible separation work
Scenario · Uniform 15 to 35 °C
Declared assumption - 60 °C
Saturation temperature of the vapour in the evaporating space (vacuum level)
Scenario · Uniform 50 to 70 °C
Declared assumptionDeclared operating assumption for evaporation of milk under vacuum; no open source verified.
- 3 K
Temperature difference across the falling film (condensing vapour to boiling product)
Scenario · Uniform 2 to 4 K
Declared assumptionDeclared design assumption. The range is kept consistent with the reported MVR consumption: an ideal compressor with a larger lift would already need more work than the documented value (see the output 'implied_lift_bat').
- 7
Largest number of effects operated in series
Technology · Fixed
Verified quoteShow verbatim quote
Up to seven stages can be operated in series, but three to five is more commonBest Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 135. EUR 29978 EN; JRC118627; doi:10.2760/243911
- 8 bar
Pressure of the motive steam of the thermocompressor (saturated)
Scenario · Uniform 6 to 12 bar
Declared assumptionDeclared assumption (absolute pressure of the plant steam header).
- 10 kWh/t
Energy consumption of an MVR evaporator
Benchmark · Fixed
Verified quoteShow verbatim quote
It is reported that the energy consumption of a MVR evaporator is approximately 10 kWh/t of water evaporated, with negligible steam consumptionBest Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 137. EUR 29978 EN; JRC118627; doi:10.2760/243911
- 0.015 kWh/kg
Total energy consumption of a single-stage MVR evaporator (comparison table)
Benchmark · Fixed
Verified quoteShow verbatim quote
MVR single-stage 0.015Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 136. EUR 29978 EN; JRC118627; doi:10.2760/243911
- 0.11 kWh/kg
Total energy consumption of TVR evaporators with 3 to 5 stages (the most common configurations)
Benchmark · Uniform 0.084 to 0.14 kWh/kg
Verified quoteShow verbatim quote
TVR 4 stages 0.110Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 136. EUR 29978 EN; JRC118627; doi:10.2760/243911
- 2,000 W/m²/K
Overall heat-transfer coefficient of the clean falling film
Scenario · Uniform 1,000 to 3,000 W/m²/K
Declared assumptionDeclared assumption; no open source verified for milk falling-film evaporators.
- 1.00 × 10⁻⁵ m²·K/W/h
Growth rate of the fouling resistance on the heating surface
Scenario · Lognormal, σ 0.7
Declared assumptionDeclared assumption (linear fouling); no open source verified. Milk fouling depends on product, pre-heat treatment and temperature; replace with the plant's measured decline of the overall coefficient.
- 0.7
Fraction of the clean duty at which a run is stopped for cleaning
Scenario · Uniform 0.6 to 0.8
Declared assumption - 44 h
Legal maximum length of a continuous evaporator run before cleaning
Regulatory · Fixed
Verified quoteShow verbatim quote
evaporators shall be cleaned at the end of a continuous operation, not to exceed forty-four (44) hoursGrade "A" Pasteurized Milk Ordinance, 2023 Revision (opens in a new tab). U.S. Department of Health and Human Services, Public Health Service, Food and Drug Administration, 2023. p. 99. PMO 2023 Revision
- 0.374294 h
Minimum duration of the cleaning-in-place of the evaporator: physical minimum of the kinetic and displacement phases plus declared hold times (output cip_time_min of the cleaning model)
Property · Triangular 0.242184, 0.374294, 0.536161 h
ComputedOutput `cip_time_min` of the cleaning model: 22.46 min [14.53, 32.17].
- 2 h
Duration of a typical cleaning-in-place programme of the evaporator
Scenario · Uniform 1.5 to 3 h
Declared assumptionDeclared assumption: rinse, alkaline wash, rinse, acid wash, rinse with operating margins, used for the typical availability. Replace with the validated programme of the plant.
- 5 min
Mean residence time of the product in the evaporator (hold-up volume over flow)
Scenario · Uniform 2 to 10 min
Declared assumption - 0.75
Share of the hold-up volume lost as a water-product mixed zone at each start-up and shut-down
Scenario · Uniform 0.5 to 1
Declared assumption - 0.005
Standard deviation of the concentrate solids under control (mass fraction)
Scenario · Uniform 0.003 to 0.01
Declared assumptionDeclared process-capability assumption; replace with the plant's measured value (density or refractometer).
- 0.02
Half-width of the solids tolerance band accepted by the dryer
Scenario · Fixed
Declared assumption
8Benchmarks
| Benchmark | Ceiling | Value | Provenance |
|---|---|---|---|
Steam requirement of single-stage evaporators, lower end (food and drink sector)Show verbatim quoteSteam requirements for single-stage evaporators range from 1.1 tonnes to 1.2 tonnes of steam per tonne of evaporated waterBest Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 787. EUR 29978 EN; JRC118627; doi:10.2760/243911 | Best documented | 1.1 | Verified quote |
Steam requirement of single-stage evaporators, lower end (multistage evaporation technique)Show verbatim quoteSteam requirements for single-stage evaporators are 1.2–1.4 t/t of evaporated waterBest Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 135. EUR 29978 EN; JRC118627; doi:10.2760/243911 | Typical | 1.2 | Verified quote |
Steam requirement of double-effect evaporators, lower endShow verbatim quoteIn the case of double or third effect, the steam requirement lowers respectively to 0.6–0.7 tonnes and 0.4 tonnes of steam per tonne of evaporated waterBest Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 787. EUR 29978 EN; JRC118627; doi:10.2760/243911 | Best documented | 0.6 | Verified quote |
Steam requirement of triple-effect evaporatorsShow verbatim quoteIn the case of double or third effect, the steam requirement lowers respectively to 0.6–0.7 tonnes and 0.4 tonnes of steam per tonne of evaporated waterBest Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 787. EUR 29978 EN; JRC118627; doi:10.2760/243911 | Best documented | 0.4 | Verified quote |
Total energy of a 7-stage TVR evaporator (dairy industry comparison table)Show verbatim quoteTVR 7 stages 0.060Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 136. EUR 29978 EN; JRC118627; doi:10.2760/243911 | Best documented | 0.06 kWh/kg | Verified quote |
Total energy of a 3-stage TVR evaporator (dairy industry comparison table)Show verbatim quoteTVR 3 stages 0.140Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 136. EUR 29978 EN; JRC118627; doi:10.2760/243911 | Typical | 0.14 kWh/kg | Verified quote |
Energy stated as required to evaporate one tonne of water (spray-drying section; compare with the ideal single-effect heat)Show verbatim quoteTaking into account that about 600 kWh energy is required to evaporate 1 tonne of waterBest Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 412. EUR 29978 EN; JRC118627; doi:10.2760/243911 | — | 600 kWh/t | Verified quote |
DOE bandwidth study, concentration of canned evaporated milk and powdered dry milk, current typical (per lb of product, a mix of evaporated milk and powder: not comparable with a value per kg of water removed)Show verbatim quoteConcentration 2,488 172 138 138 0Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Food and Beverage Manufacturing (opens in a new tab). U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Advanced Manufacturing Office, 2017. p. 57. DOE/EE-1571; OSTI ID 1512366 | Typical | 172 Btu/lb | Verified quote |
DOE bandwidth study, concentration, state of the art (same basis as the current typical value)Show verbatim quoteConcentration 2,488 172 138 138 0Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Food and Beverage Manufacturing (opens in a new tab). U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Advanced Manufacturing Office, 2017. p. 57. DOE/EE-1571; OSTI ID 1512366 | Best available technique | 138 Btu/lb | Verified quote |
DOE bandwidth study, concentration, thermodynamic minimum (set to zero for lack of chemical conversion; the separation work is not counted)Show verbatim quoteConcentration 2,488 172 138 138 0Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Food and Beverage Manufacturing (opens in a new tab). U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Advanced Manufacturing Office, 2017. p. 57. DOE/EE-1571; OSTI ID 1512366 | Theoretical | 0 Btu/lb | Verified quote |
9Unavoidable stops
- Cleaning at the end of each continuous run (at most every 44 h)Verified quote
Milk proteins and minerals foul the heating surface, so the duty falls during a run; hygiene regulation also caps a continuous evaporator run at 44 hours. For the bound the run ends at the length that maximises A x P x Q (at most 44 h), followed by cleaning-in-place of minimum duration (cleaning model).
Show verbatim quote
evaporators shall be cleaned at the end of a continuous operation, not to exceed forty-four (44) hoursGrade "A" Pasteurized Milk Ordinance, 2023 Revision (opens in a new tab). U.S. Department of Health and Human Services, Public Health Service, Food and Drug Administration, 2023. p. 99. PMO 2023 Revision
10Assumptions
- The minimum cleaning duration comes from the cleaning model, whose validity covers recirculated pipe and plate circuits; the falling-film tubes are pipes, but the distribution of the cleaning liquid over the tube plate and the vapour side of the calandria are outside that validity, so the linked duration is a lower bound for the evaporator. The bound uses the run length that maximises A x P x Q (fouling decline, cleaning and start-up losses together), capped by the legal 44 h; the declared duty floor and the typical cleaning duration give the typical availability.
- The dissolved solutes (lactose and the soluble salts) form an ideal solution: a_w = n_w / (n_w + n_s) (Raoult). Fat, casein micelles and colloidal salts do not lower the water activity. The real activity of a concentrated milk is somewhat lower, so the separation work is a lower bound, as a theoretical ceiling must be.
- The boiling-point elevation is obtained exactly from the water activity: the solution boils where a_w p_sat(T) equals the vapour-space pressure (IAPWS-95 saturation pressure, CoolProp).
- Energy is compared as final energy per kg of water removed, as in the BAT reference document (Table 2.41): heat for steam-driven evaporators, electricity for MVR. Primary-energy factors are outside the boundary.
- Fouling adds a resistance that grows linearly in time; the temperature difference is held constant, so the duty falls as U(t) = 1/(1/U0 + R_f t). A plant that raises the temperature difference instead keeps the rate and pays in energy.
- Start-up and shut-down losses are the water-product mixed zones, a declared share of the hold-up volume at each transition; concentrate outside the solids band is recirculated and counted as a quality loss.
11Range of validity
- Whole milk concentrated to 50–60 % solids under vacuum (vapour saturation 50–70 °C) in falling-film evaporators.
- For fruit juices replace the composition parameters (sugars dominate the water activity) and the regulatory run length.
12Sensitivity
- Overall heat-transfer coefficient of the clean falling filmelasticity -0.066Spearman ρ -0.36
- Growth rate of the fouling resistance on the heating surfaceelasticity -0.066Spearman ρ -0.85
- Minimum duration of the cleaning-in-place of the evaporator: physical minimum of the kinetic and displacement phases plus declared hold times (output cip_time_min of the cleaning model)elasticity -0.048Spearman ρ -0.13
- Mean residence time of the product in the evaporator (hold-up volume over flow)elasticity -0.017Spearman ρ -0.13
- Share of the hold-up volume lost as a water-product mixed zone at each start-up and shut-downelasticity -0.017Spearman ρ -0.07
- Half-width of the solids tolerance band accepted by the dryerelasticity +0.001Spearman ρ —
- Standard deviation of the concentrate solids under control (mass fraction)elasticity -0.001Spearman ρ -0.21
- Legal maximum length of a continuous evaporator run before cleaningelasticity 0.000Spearman ρ —
- Output rises with the parameter
- Output falls with the parameter
13Validation checks
- Dimensional analysis30 outputs converted to their declared unitsPassed
- Every cited value verified against its source21 verified, 0 failedPassed
- No documented value beats the theoretical limitPassed
- Ceilings in physical orderPassed
- Fractions within 0 and 1Passed
14Causes of loss in this operation
- Sucrose Loss to Acid Hydrolysis in EvaporationProcess defects (scrap and rework)2.5% [0.5–6.7%]C29 studies
15References
- Best Available Techniques (BAT) Reference Document for the Food, Drink and Milk Industries (opens in a new tab). European Commission, Joint Research Centre; Publications Office of the European Union, 2019. p. 411. EUR 29978 EN; JRC118627; doi:10.2760/243911
- Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Food and Beverage Manufacturing (opens in a new tab). U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Advanced Manufacturing Office, 2017. p. 57. DOE/EE-1571; OSTI ID 1512366
- Grade "A" Pasteurized Milk Ordinance, 2023 Revision (opens in a new tab). U.S. Department of Health and Human Services, Public Health Service, Food and Drug Administration, 2023. p. 99. PMO 2023 Revision
- USDA National Nutrient Database for Standard Reference, Release 28 (2015): Food Group 01, Dairy and Egg Products (nutrient report) (opens in a new tab). U.S. Department of Agriculture, Agricultural Research Service, Nutrient Data Laboratory, 2015. p. 632. USDA SR28, food group 01 report (sr28fg01.pdf)
- doi:10.1021/ie4033999 — CoolProp: IAPWS-95 water properties (saturation, enthalpy, entropy).
- doi:10.1063/1.1461829 — IAPWS-95 formulation for water.