Container Body or Seal Defect
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 49 % of the line's lost time. Reported by 1 of the 120 studies that could observe it (sparse evidence).
What happens
Filled containers are rejected because the container body shows deformation, cracks, flash or dimensional faults, or because the closure/seal is incomplete, misaligned or leaking. These faults usually originate upstream in container moulding, handling or the capping/sealing head rather than in the filler itself, but they are only detected and counted once the unit reaches the filling or inspection stage.
What is done about it
Reinforce incoming container quality checks and supplier specifications, and calibrate or adjust the sealing/capping head pressure, temperature and alignment. Periodic preventive inspection of mould and seal-forming tooling reduces recurrence of body and seal faults.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 0.6% [0.1–1.5%]
- Expected share of lost time
- 0.3% [0.1–0.7%]
- Share of lost time when present
- 49% [38–61%]
- Studies / units
- 120 / 162
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products0.6% [0.1–2.1%]18 studies
- Soft drinks, bottled water and juices0.5% [0.1–1.7%]44 studies
- Brewing, wine and spirits0.6% [0.1–2.2%]16 studies
- Bakery and pasta0.7% [0.1–2.6%]0 studies
- Meat, poultry and seafood0.6% [0.1–2.4%]6 studies
- Fruit and vegetable processing0.7% [0.1–2.6%]4 studies
- Grain and oilseed milling1.0% [0.1–3.6%]6 studies
- Sugar and confectionery0.7% [0.1–2.4%]3 studies
- Snacks, coffee, tea and other foods0.6% [0.1–2.5%]6 studies
- Animal feed and pet food0.7% [0.1–2.5%]4 studies
- Food manufacturing (unspecified or mixed)0.6% [0.1–2.3%]13 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceFilled containers are rejected because the container body shows deformation, cracks, flash or dimensional faults, or because the closure/seal is incomplete, misaligned or leaking. These faults usually originate upstream in container moulding, handling or the capping/sealing head rather than in the filler itself, but they are only detected and counted once the unit reaches the filling or inspection stage.
How it looks in SCADA data
Engineering guidanceMES/quality logs show an increase in reject counts tagged with body-defect or seal-defect codes at the filling or downstream inspection station, while the filler machine state remains in run with no fault alarm. No equipment stoppage is typically associated; the signature is a rise in the defect-rate counter rather than a downtime event.
Countermeasure
Engineering guidanceReinforce incoming container quality checks and supplier specifications, and calibrate or adjust the sealing/capping head pressure, temperature and alignment. Periodic preventive inspection of mould and seal-forming tooling reduces recurrence of body and seal faults.
4Sources
- Integration of Overall Equipment Effectiveness and Six Sigma Approach to Minimize Product Defect and Machine Downtime (2023)Open sourceShare of loss events: 22.0 % · as reported: “Body Defect”
Show verbatim quote
Body Defect 1012 22
- Integration of Overall Equipment Effectiveness and Six Sigma Approach to Minimize Product Defect and Machine Downtime (2023)Open sourceNumber of events: 1,012 units · as reported: “Body Defect”
Show verbatim quote
Body Defect 1012 22
- Integration of Overall Equipment Effectiveness and Six Sigma Approach to Minimize Product Defect and Machine Downtime (2023)Open sourceShare of loss events: 56.0 % · as reported: “Seal Defect”
Show verbatim quote
Seal Defect 2555 56
- Integration of Overall Equipment Effectiveness and Six Sigma Approach to Minimize Product Defect and Machine Downtime (2023)Open sourceNumber of events: 2,555 units · as reported: “Seal Defect”
Show verbatim quote
Seal Defect 2555 56
- Proposal for improvement to increase the overall equipment effectiveness (OEE) of a dairy products company through a Preventive Maintenance Plan, Standardized Work, and SMED (2025)Open sourceShare of planned time: 0.0500 % · as reported: “Defectuosos”
Show verbatim quote
Charlas /Reuniones Velocidad reducida Defectuosos 1,50% 2,10% 0,05%
- Proposal for improvement to increase the overall equipment effectiveness (OEE) of a dairy products company through a Preventive Maintenance Plan, Standardized Work, and SMED (2025)Open sourceShare of planned time: 0.0500 % · as reported: “Defectuosos”
Show verbatim quote
Charlas /Reuniones Velocidad reducida Defectuosos 1,50% 1,00% 0,05%