Dosing/lobe pump jamming failure

Equipment failure (breakdowns)AvailabilityFilling

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 57 % of the line's lost time. Reported by 1 of the 120 studies that could observe it (sparse evidence).

What happens

The positive-displacement dosing or lobe pump that meters product to the filler jams when foreign particles, product build-up, crystallized residue or worn rotor/lobe clearances cause the internal rotating elements to seize or stall against the pump housing. The resulting mechanical lock-up stops product flow and requires maintenance to free, clean or replace the affected pump components before filling can resume.

What is done about it

Install inlet strainers or filters to keep foreign material and clumps out of the pump, and schedule preventive disassembly, cleaning and inspection of rotors, lobes and seals at defined intervals. Monitor motor torque/current trend and set early-warning thresholds to detect rising resistance before a full jam occurs, and ensure product viscosity/temperature stays within the pump's rated operating window.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
0.6% [0.1–1.6%]
Expected share of lost time
0.3% [0.1–0.9%]
Share of lost time when present
57% [46–67%]
Studies / units
120 / 162
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    0.9% [0.1–3.3%]18 studies
  • Soft drinks, bottled water and juices
    0.5% [0.1–1.8%]44 studies
  • Brewing, wine and spirits
    0.6% [0.1–2.2%]16 studies
  • Bakery and pasta
    0.7% [0.1–2.7%]0 studies
  • Meat, poultry and seafood
    0.7% [0.1–2.3%]6 studies
  • Fruit and vegetable processing
    0.7% [0.1–2.5%]4 studies
  • Grain and oilseed milling
    0.7% [0.1–2.5%]6 studies
  • Sugar and confectionery
    0.7% [0.1–2.7%]3 studies
  • Snacks, coffee, tea and other foods
    0.7% [0.1–2.5%]6 studies
  • Animal feed and pet food
    0.7% [0.1–2.6%]4 studies
  • Food manufacturing (unspecified or mixed)
    0.6% [0.1–2.4%]13 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

The positive-displacement dosing or lobe pump that meters product to the filler jams when foreign particles, product build-up, crystallized residue or worn rotor/lobe clearances cause the internal rotating elements to seize or stall against the pump housing. The resulting mechanical lock-up stops product flow and requires maintenance to free, clean or replace the affected pump components before filling can resume.

How it looks in SCADA data

Engineering guidance

SCADA shows a sudden spike in pump motor current or torque followed by a drive overload/trip alarm, with pump speed feedback dropping to zero while the motor remains commanded to run. Filler head or downstream fill-volume signals fall to zero simultaneously, line state changes to fault/stopped, and upstream buffer or tank levels rise due to blocked outflow.

Countermeasure

Engineering guidance

Install inlet strainers or filters to keep foreign material and clumps out of the pump, and schedule preventive disassembly, cleaning and inspection of rotors, lobes and seals at defined intervals. Monitor motor torque/current trend and set early-warning thresholds to detect rising resistance before a full jam occurs, and ensure product viscosity/temperature stays within the pump's rated operating window.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Number of events: 6.00 events · as reported: “Dosing Pump”
    Show verbatim quote
    Dosing Pump 6
  2. Lost time: 32.5 h · as reported: “Pump jamming”
    Show verbatim quote
    Trabamiento de bomba 32,50 31%