Electrical component failure
In short
It appears in about 1 of every 100 lines studied.
When it appears, it takes on average about 58 % of the line's lost time. Reported by 2 of the 43 studies that could observe it (sparse evidence).
What happens
An electrical component such as a motor, contactor, relay, sensor wiring or power supply degrades or fails, interrupting the control or drive circuit of the milling equipment and halting operation until the fault is cleared. The failure can originate from insulation breakdown, loose or corroded connections, overload tripping, or component end-of-life.
What is done about it
Implement predictive and preventive electrical maintenance programs including thermographic inspection, periodic tightening and cleaning of connections, and condition monitoring of motors and drives, along with timely replacement of components approaching end-of-life.
Practical guidance written from engineering knowledge; it is not a statistical estimate.
1Probability and evidence
- Probability of presence
- 1.0% [0.2–2.9%]
- Expected share of lost time
- 0.6% [0.1–1.6%]
- Share of lost time when present
- 58% [47–68%]
- Studies / units
- 43 / 48
- Evidence grade
- D
Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.
2Probability by segment
- Dairy products1.1% [0.1–4.4%]5 studies
- Soft drinks, bottled water and juices1.2% [0.1–4.6%]1 study
- Brewing, wine and spirits1.1% [0.1–4.7%]0 studies
- Bakery and pasta1.2% [0.1–4.6%]0 studies
- Meat, poultry and seafood1.2% [0.1–4.6%]0 studies
- Fruit and vegetable processing1.1% [0.1–4.5%]2 studies
- Grain and oilseed milling1.1% [0.1–4.3%]7 studies
- Sugar and confectionery1.5% [0.2–5.5%]10 studies
- Snacks, coffee, tea and other foods1.1% [0.1–3.9%]5 studies
- Animal feed and pet food1.1% [0.1–3.9%]6 studies
- Food manufacturing (unspecified or mixed)1.1% [0.1–4.4%]7 studies
3Mechanism, SCADA signature and countermeasure
Mechanism
Engineering guidanceAn electrical component such as a motor, contactor, relay, sensor wiring or power supply degrades or fails, interrupting the control or drive circuit of the milling equipment and halting operation until the fault is cleared. The failure can originate from insulation breakdown, loose or corroded connections, overload tripping, or component end-of-life.
How it looks in SCADA data
Engineering guidanceSCADA/MES logs show an unplanned stop event tagged with an electrical fault or trip code, often preceded by abnormal current, voltage or temperature readings on the affected drive or motor branch. The machine state transitions directly from running to fault/down without an operator-initiated stop command, and the downtime is closed by a maintenance work order referencing electrical repair.
Countermeasure
Engineering guidanceImplement predictive and preventive electrical maintenance programs including thermographic inspection, periodic tightening and cleaning of connections, and condition monitoring of motors and drives, along with timely replacement of components approaching end-of-life.
4Sources
- Strategic formulation of industrial maintenance based on equipment reliability in a sugar and ethanol production plant (2020)Open sourceTime between events: 5.56 log(min) · as reported: “Electrical Maintenance”
Show verbatim quote
Electrical Maintenance 218 5.564 (5.330; 5.797)
- Strategic formulation of industrial maintenance based on equipment reliability in a sugar and ethanol production plant (2020)Open sourceNumber of events: 218 events · as reported: “Electrical Maintenance”
Show verbatim quote
Electrical Maintenance 218 5.564 (5.330; 5.797)
- ESTRATÉGIA DE MANUTENÇÃO EM UMA USINA DE AÇUCAR E ALCOOL UTILIZANDO MODELO ESTATÍSTICO DE CONFIABILIDADE (2024)Open sourceNumber of events: 97.0 events · as reported: “Electrical Maintenance (ELET)”
Show verbatim quote
ELET 97 61,9 108,5 11763,1 28,2
- ESTRATÉGIA DE MANUTENÇÃO EM UMA USINA DE AÇUCAR E ALCOOL UTILIZANDO MODELO ESTATÍSTICO DE CONFIABILIDADE (2024)Open sourceMean event duration: 61.9 min · as reported: “Electrical Maintenance (ELET)”
Show verbatim quote
ELET 97 61,9 108,5 11763,1 28,2