foratvise
Get Started
Equipment failure (breakdowns)

Electrical component failure

Equipment failure (breakdowns)AvailabilityMilling and grinding

In short

It appears in about 1 of every 100 lines studied.

When it appears, it takes on average about 58 % of the line's lost time. Reported by 2 of the 43 studies that could observe it (sparse evidence).

What happens

An electrical component such as a motor, contactor, relay, sensor wiring or power supply degrades or fails, interrupting the control or drive circuit of the milling equipment and halting operation until the fault is cleared. The failure can originate from insulation breakdown, loose or corroded connections, overload tripping, or component end-of-life.

What is done about it

Implement predictive and preventive electrical maintenance programs including thermographic inspection, periodic tightening and cleaning of connections, and condition monitoring of motors and drives, along with timely replacement of components approaching end-of-life.

Practical guidance written from engineering knowledge; it is not a statistical estimate.

1Probability and evidence

Pooled over all segments. A wide interval is a result: it states how much the evidence allows us to know.
Probability of presence
1.0% [0.2–2.9%]
Expected share of lost time
0.6% [0.1–1.6%]
Share of lost time when present
58% [47–68%]
Studies / units
43 / 48
Evidence grade
D

Grade D: 0 or 1 study; the estimate is driven by partial pooling and priors, and the wide interval is the result.

2Probability by segment

Partially pooled estimates for each industry segment.
  • Dairy products
    1.1% [0.1–4.4%]5 studies
  • Soft drinks, bottled water and juices
    1.2% [0.1–4.6%]1 study
  • Brewing, wine and spirits
    1.1% [0.1–4.7%]0 studies
  • Bakery and pasta
    1.2% [0.1–4.6%]0 studies
  • Meat, poultry and seafood
    1.2% [0.1–4.6%]0 studies
  • Fruit and vegetable processing
    1.1% [0.1–4.5%]2 studies
  • Grain and oilseed milling
    1.1% [0.1–4.3%]7 studies
  • Sugar and confectionery
    1.5% [0.2–5.5%]10 studies
  • Snacks, coffee, tea and other foods
    1.1% [0.1–3.9%]5 studies
  • Animal feed and pet food
    1.1% [0.1–3.9%]6 studies
  • Food manufacturing (unspecified or mixed)
    1.1% [0.1–4.4%]7 studies

3Mechanism, SCADA signature and countermeasure

Engineering guidance that helps recognise and address the cause; it is not part of the statistical estimate.

Mechanism

Engineering guidance

An electrical component such as a motor, contactor, relay, sensor wiring or power supply degrades or fails, interrupting the control or drive circuit of the milling equipment and halting operation until the fault is cleared. The failure can originate from insulation breakdown, loose or corroded connections, overload tripping, or component end-of-life.

How it looks in SCADA data

Engineering guidance

SCADA/MES logs show an unplanned stop event tagged with an electrical fault or trip code, often preceded by abnormal current, voltage or temperature readings on the affected drive or motor branch. The machine state transitions directly from running to fault/down without an operator-initiated stop command, and the downtime is closed by a maintenance work order referencing electrical repair.

Countermeasure

Engineering guidance

Implement predictive and preventive electrical maintenance programs including thermographic inspection, periodic tightening and cleaning of connections, and condition monitoring of motors and drives, along with timely replacement of components approaching end-of-life.

4Sources

Every extracted datum with its study, value and verbatim quote.
  1. Time between events: 5.56 log(min) · as reported: “Electrical Maintenance”
    Show verbatim quote
    Electrical Maintenance 218 5.564 (5.330; 5.797)
  2. Number of events: 218 events · as reported: “Electrical Maintenance”
    Show verbatim quote
    Electrical Maintenance 218 5.564 (5.330; 5.797)
  3. Number of events: 97.0 events · as reported: “Electrical Maintenance (ELET)”
    Show verbatim quote
    ELET 97 61,9 108,5 11763,1 28,2
  4. Mean event duration: 61.9 min · as reported: “Electrical Maintenance (ELET)”
    Show verbatim quote
    ELET 97 61,9 108,5 11763,1 28,2